The Thermo Scientific molecular biology portfolio offers the most reliable genetic content, superior enzymes and advanced PCR tools to support and facilitate your entire cloning workflow. Our products meet the industry's highest quality control standards and provide performance, accuracy and consistency. Find out more about Thermo Scientific products for each of your cloning workflow steps starting from sample preparation to fragment amplification, DNA modification, electrophoresis, and ligation by clicking on the navigation buttons on the menu bar below.

 

High yields & exceptional value

Thermo Scientific GeneJET nucleic acid purification kits are designed for rapid, efficient, and convenient purification of DNA and RNA from a wide range of samples. The kits utilize a proprietary silica-based membrane technology in the form of a convenient spin-column eliminating the need for expensive resins, toxic phenol-chloroform extractions, or time-consuming alcohol precipitation. Purified DNA or RNA is ready to use in all common molecular biology procedures.

Features

  • Efficient nucleic acid extraction and high yields
  • High purity of isolated DNA or RNA
  • Simple and fast isolation procedure
  • Convenient silica-based spin column format

Applications

  • Plasmid DNA isolation
  • Genomic DNA isolation
  • Total RNA isolation
  • PCR purification
  • Gel extraction
Kit




Learn more

High-fidelity PCR

In cloning applications, it is crucial to maintain accurate DNA sequences during amplification. Thermo Scientific Phusion High-Fidelity DNA Polymerases have extremely low error rates and set a gold standard for high-fidelity PCR.

  • Extreme fidelity (error rate 4.4 x 10-7 in Phusion HF Buffer)
  • Polymerase speed allows for short extension times (15-30 s/kb)
  • Robust performance, minimal optimization needed
  • Increased product yields with minimal amounts of enzyme
  • Green Buffer for direct loading of PCR products on gels

Reverse Transcriptases
Thermo Scientific Maxima Reverse Transcriptases have been developed through in vitro evolution of M-MuLV reverse transcriptase to yield dramatically improved thermostability, robustness and increased synthesis rate compared to wild-type M-MuLV RT.

Thermal Cyclers
Small and fast, the Thermo Scientific Piko Thermal Cycler delivers superior thermal performance in a compact package and enables PCR runs in as little as 15 minutes. For routine PCR, the Thermo Scientific Arktik Thermal Cycler is a reliable and easy-to-use instrument designed to meet everyday requirements in any PCR laboratory.

Consumables
Thermo Scientific PCR plastics are manufactured with industry-leading processes and extensive quality control to ensure maximum PCR performance. The UTW (ultra-thin wall) PCR plastics allow shorter PCR run times by improving heat transfer.

Learn more

Restriction digestion as easy as it gets

Thermo Scientific FastDigest Enzymes are an advanced line of 176 restriction enzymes designed for rapid DNA digestion. All FastDigest enzymes are 100% active in the universal FastDigest and FastDigest Green reaction buffers and are able to digest DNA in 5-15 minutes. This enables any combination of restriction enzymes to work simultaneously in one reaction tube and eliminates the need for sequential digestions. As an added convenience, the FastDigest Green buffer allows for direct loading of the reaction mixture on gels.

  • 100% activity of all FastDigest enzymes in one buffer
  • Complete DNA digestion in 5-15 minutes
  • 100% buffer compatibility with downstream applications
  • Direct loading of reaction products on gels
  • 176 FastDigest Enzymes available
 Old Standard
Conventional restriction enzymes
New Standard
FastDigest restriction enzymes
Buffer systemUp to 20 buffersOne universal buffer
Buffer change between enzymatic stepsFrequently necessaryNot necessary
Double/multiple restriction digestionLimited to buffer incompatibilityAny digestion combination possible
Reaction time1 hour - overnight5 - 15 minutes
Direct loading on gelsNoYes
Downstream applicationsPartial compatibility100% compatibility
Star activityDependent on enzyme properties and reaction conditionsNo star activity due to short incubation time
Activity definition1 unit of enzyme hydrolyzes 1 µg of lambda DNA in 60 minutes in an optimal buffer for an enzyme1 µl of FastDigest enzyme cleaves 1 µg of substrate DNA in 5 or 15 minutes of FastDigest buffer

Modification of DNA fragment ends prior to ligation is an essential step to the overall success of a cloning experiment. With the Thermo Scientific FastAP Alkaline Phosphatase and Thermo Scientific Fast DNA End Repair Kit, modification of DNA ends is fast and effective.

FastAP Alkaline Phosphatase

FastAP Alkaline Phosphatase is ideal for rapid and efficient dephosphorylation of linearized vector DNA in just 10 min. Complete thermal inactivation of the enzyme in just 5 minutes makes FastAP a faster and more efficient alternative to SAP.

Features

  • Fast 10 min dephosphorylation of all types of DNA ends
  • Rapid thermal inactivation with only 5 min at 75°C
  • Simultaneous digestion and dephosphorylation of vector DNA
  • 100% active in restriction enzyme and PCR buffers

Fast DNA End Repair Kit

The new Fast DNA End Repair Kit is designed for fast and efficient DNA fragment blunting and phosphorylation prior to ligation. This kit can be used with all types of double-stranded DNA:

  • Fragmented genomic DNA (restriction enzyme digested, nebulized or sonicated)
  • Restriction enzyme digested plasmid DNA
  • Double-stranded cDNA
  • PCR products with 3'-dA overhangs

Features

  • Efficient—blunting and phosphorylation of double-stranded DNA
  • Fast—reaction is complete in 5 minutes
  • Convenient—reaction components are premixed to reduce pipetting steps

Efficient ligation of DNA fragments following end repair with the Fast DNA End Repair kit (Figure 1).  A 130 bp PCR product with 3'- dA overhangs was end-repaired using the Fast DNA End Repair Kit and kits from other vendors according to supplier's recommendations and subsequently ligated with T4 DNA Ligase (#EL0014). Ligation conditions: 200 ng of a 130 bp PCR product ligated with 5U T4 DNA Ligase in 1X T4 DNA Ligase Buffer with 5% PEG 4000 for 1 hour at 22°C.

Fast DNA End Repair kit

Figure 1. Fast DNA End Repair kit.
Lane M – GeneRuler 1 kb Plus DNA Ladder (#SM1333),
Lane C1 – PCR product,
Lane C2 – PCR product after ligation, 
Lane T – PCR product after end repair using Fast DNA End Repair Kit (20°C, 5 min) and ligation,
Lane A – PCR product after end repair using Vendor A kit (20°C, 30 min) and ligation,
Lane B – PCR product after end repair using Vendor B kit (RT, 45 min; 70°C, 10 min) and ligation.

Designed for perfect migration

The Thermo Scientific molecular biology portfolio offers the widest selection of DNA ladders ranging from 10 bp to 48.5 kb for accurate analysis of linear double-stranded DNA in agarose or polyacrylamide gels.  All of our DNA ladders are composed of individual chromatography-purified DNA fragments produced with a patented technology used to prepare pharmaceutical grade plasmid DNA.

Features

  • Broad selection of DNA ladders.
  • Composed of individual chromatography-purified DNA fragments.
  • Bright, sharp bands.
  • Ideal for in-gel DNA quantification.
  • Supplied with extra loading dye for sample DNA.
  • Ready-to-use DNA ladders are stable at room temperature for at least 6 months.
DNA Ladder LineDescriptionRun Time
GeneRuler DNA Ladders1 kb Ladder, 100 bp ladder and other popular DNA ladders for accurate DNA sizing45 min
FastRuler DNA LaddersRapid DNA separation. Ideal for sizing and quantification of PCR products8–14 min
MassRuler DNA LaddersAccurate in-gel quantification of DNA fragments45 min
O'RangeRuler DNA LaddersStep-ladders designed for precise sizing of DNA fragments in agarose or non-denaturing polyacrylamide gels45–90 min
NoLimits Individual DNA FragmentsA collection of 36 highly-purified individual DNA fragments ranging in size from 10–20,000 bpVaries
NO limits

Figure 2. 1.1% TopVision Agarose, 1X TAE, 7 V/cm, 30 min. NoLimits DNA fragments from 300 bp to 10 kb

GeneRuler DNA Ladders

Figure 3. GeneRuler DNA Ladders

Rapid DNA Ligation Kit

The Rapid DNA Ligation Kit allows sticky-end or blunt-end DNA ligation in only 5 min at room temperature. The kit contains T4 DNA Ligase and a specially formulated 5X Rapid Ligation Buffer.

Features

  • Fast—ligation of either sticky- or blunt-end DNA in only 5 minutes.
  • Convenient—reaction mixture can be used directly for bacterial transformation.

CloneJET PCR Cloning Kit

The CloneJET PCR Cloning Kit is an advanced positive-selection system for high efficiency cloning of PCR products generated with any thermostable DNA polymerase. Additionally, any other blunt or sticky-end DNA fragment can also be cloned using the CloneJET kit. The kit is compatible with phosphorylated or non-phosphorylated DNA fragments. Ligation into the included positive selection vector takes only 5 minutes and yields more than 99% recombinant clones.

Features

  • Fast—PCR cloning in only 5–10 minutes.
  • High efficiency— >99% positive clones.
  • No cloning background with the positive selection pJET1.2 vector.
  • Economical—eliminates the need for expensive blue/white screening.

Learn more

pJET1.1/blunt vector map
Figure 4. pJET1.2/blunt vector map.

High yields & exceptional value

Thermo Scientific GeneJET nucleic acid purification kits are designed for rapid, efficient, and convenient purification of DNA and RNA from a wide range of samples. The kits utilize a proprietary silica-based membrane technology in the form of a convenient spin-column eliminating the need for expensive resins, toxic phenol-chloroform extractions, or time-consuming alcohol precipitation. Purified DNA or RNA is ready to use in all common molecular biology procedures.

Features

  • Efficient nucleic acid extraction and high yields
  • High purity of isolated DNA or RNA
  • Simple and fast isolation procedure
  • Convenient silica-based spin column format

Applications

  • Plasmid DNA isolation
  • Genomic DNA isolation
  • Total RNA isolation
  • PCR purification
  • Gel extraction
Kit




Learn more

High-fidelity PCR

In cloning applications, it is crucial to maintain accurate DNA sequences during amplification. Thermo Scientific Phusion High-Fidelity DNA Polymerases have extremely low error rates and set a gold standard for high-fidelity PCR.

  • Extreme fidelity (error rate 4.4 x 10-7 in Phusion HF Buffer)
  • Polymerase speed allows for short extension times (15-30 s/kb)
  • Robust performance, minimal optimization needed
  • Increased product yields with minimal amounts of enzyme
  • Green Buffer for direct loading of PCR products on gels

Reverse Transcriptases
Thermo Scientific Maxima Reverse Transcriptases have been developed through in vitro evolution of M-MuLV reverse transcriptase to yield dramatically improved thermostability, robustness and increased synthesis rate compared to wild-type M-MuLV RT.

Thermal Cyclers
Small and fast, the Thermo Scientific Piko Thermal Cycler delivers superior thermal performance in a compact package and enables PCR runs in as little as 15 minutes. For routine PCR, the Thermo Scientific Arktik Thermal Cycler is a reliable and easy-to-use instrument designed to meet everyday requirements in any PCR laboratory.

Consumables
Thermo Scientific PCR plastics are manufactured with industry-leading processes and extensive quality control to ensure maximum PCR performance. The UTW (ultra-thin wall) PCR plastics allow shorter PCR run times by improving heat transfer.

Learn more

Restriction digestion as easy as it gets

Thermo Scientific FastDigest Enzymes are an advanced line of 176 restriction enzymes designed for rapid DNA digestion. All FastDigest enzymes are 100% active in the universal FastDigest and FastDigest Green reaction buffers and are able to digest DNA in 5-15 minutes. This enables any combination of restriction enzymes to work simultaneously in one reaction tube and eliminates the need for sequential digestions. As an added convenience, the FastDigest Green buffer allows for direct loading of the reaction mixture on gels.

  • 100% activity of all FastDigest enzymes in one buffer
  • Complete DNA digestion in 5-15 minutes
  • 100% buffer compatibility with downstream applications
  • Direct loading of reaction products on gels
  • 176 FastDigest Enzymes available
 Old Standard
Conventional restriction enzymes
New Standard
FastDigest restriction enzymes
Buffer systemUp to 20 buffersOne universal buffer
Buffer change between enzymatic stepsFrequently necessaryNot necessary
Double/multiple restriction digestionLimited to buffer incompatibilityAny digestion combination possible
Reaction time1 hour - overnight5 - 15 minutes
Direct loading on gelsNoYes
Downstream applicationsPartial compatibility100% compatibility
Star activityDependent on enzyme properties and reaction conditionsNo star activity due to short incubation time
Activity definition1 unit of enzyme hydrolyzes 1 µg of lambda DNA in 60 minutes in an optimal buffer for an enzyme1 µl of FastDigest enzyme cleaves 1 µg of substrate DNA in 5 or 15 minutes of FastDigest buffer

Modification of DNA fragment ends prior to ligation is an essential step to the overall success of a cloning experiment. With the Thermo Scientific FastAP Alkaline Phosphatase and Thermo Scientific Fast DNA End Repair Kit, modification of DNA ends is fast and effective.

FastAP Alkaline Phosphatase

FastAP Alkaline Phosphatase is ideal for rapid and efficient dephosphorylation of linearized vector DNA in just 10 min. Complete thermal inactivation of the enzyme in just 5 minutes makes FastAP a faster and more efficient alternative to SAP.

Features

  • Fast 10 min dephosphorylation of all types of DNA ends
  • Rapid thermal inactivation with only 5 min at 75°C
  • Simultaneous digestion and dephosphorylation of vector DNA
  • 100% active in restriction enzyme and PCR buffers

Fast DNA End Repair Kit

The new Fast DNA End Repair Kit is designed for fast and efficient DNA fragment blunting and phosphorylation prior to ligation. This kit can be used with all types of double-stranded DNA:

  • Fragmented genomic DNA (restriction enzyme digested, nebulized or sonicated)
  • Restriction enzyme digested plasmid DNA
  • Double-stranded cDNA
  • PCR products with 3'-dA overhangs

Features

  • Efficient—blunting and phosphorylation of double-stranded DNA
  • Fast—reaction is complete in 5 minutes
  • Convenient—reaction components are premixed to reduce pipetting steps

Efficient ligation of DNA fragments following end repair with the Fast DNA End Repair kit (Figure 1).  A 130 bp PCR product with 3'- dA overhangs was end-repaired using the Fast DNA End Repair Kit and kits from other vendors according to supplier's recommendations and subsequently ligated with T4 DNA Ligase (#EL0014). Ligation conditions: 200 ng of a 130 bp PCR product ligated with 5U T4 DNA Ligase in 1X T4 DNA Ligase Buffer with 5% PEG 4000 for 1 hour at 22°C.

Fast DNA End Repair kit

Figure 1. Fast DNA End Repair kit.
Lane M – GeneRuler 1 kb Plus DNA Ladder (#SM1333),
Lane C1 – PCR product,
Lane C2 – PCR product after ligation, 
Lane T – PCR product after end repair using Fast DNA End Repair Kit (20°C, 5 min) and ligation,
Lane A – PCR product after end repair using Vendor A kit (20°C, 30 min) and ligation,
Lane B – PCR product after end repair using Vendor B kit (RT, 45 min; 70°C, 10 min) and ligation.

Designed for perfect migration

The Thermo Scientific molecular biology portfolio offers the widest selection of DNA ladders ranging from 10 bp to 48.5 kb for accurate analysis of linear double-stranded DNA in agarose or polyacrylamide gels.  All of our DNA ladders are composed of individual chromatography-purified DNA fragments produced with a patented technology used to prepare pharmaceutical grade plasmid DNA.

Features

  • Broad selection of DNA ladders.
  • Composed of individual chromatography-purified DNA fragments.
  • Bright, sharp bands.
  • Ideal for in-gel DNA quantification.
  • Supplied with extra loading dye for sample DNA.
  • Ready-to-use DNA ladders are stable at room temperature for at least 6 months.
DNA Ladder LineDescriptionRun Time
GeneRuler DNA Ladders1 kb Ladder, 100 bp ladder and other popular DNA ladders for accurate DNA sizing45 min
FastRuler DNA LaddersRapid DNA separation. Ideal for sizing and quantification of PCR products8–14 min
MassRuler DNA LaddersAccurate in-gel quantification of DNA fragments45 min
O'RangeRuler DNA LaddersStep-ladders designed for precise sizing of DNA fragments in agarose or non-denaturing polyacrylamide gels45–90 min
NoLimits Individual DNA FragmentsA collection of 36 highly-purified individual DNA fragments ranging in size from 10–20,000 bpVaries
NO limits

Figure 2. 1.1% TopVision Agarose, 1X TAE, 7 V/cm, 30 min. NoLimits DNA fragments from 300 bp to 10 kb

GeneRuler DNA Ladders

Figure 3. GeneRuler DNA Ladders

Rapid DNA Ligation Kit

The Rapid DNA Ligation Kit allows sticky-end or blunt-end DNA ligation in only 5 min at room temperature. The kit contains T4 DNA Ligase and a specially formulated 5X Rapid Ligation Buffer.

Features

  • Fast—ligation of either sticky- or blunt-end DNA in only 5 minutes.
  • Convenient—reaction mixture can be used directly for bacterial transformation.

CloneJET PCR Cloning Kit

The CloneJET PCR Cloning Kit is an advanced positive-selection system for high efficiency cloning of PCR products generated with any thermostable DNA polymerase. Additionally, any other blunt or sticky-end DNA fragment can also be cloned using the CloneJET kit. The kit is compatible with phosphorylated or non-phosphorylated DNA fragments. Ligation into the included positive selection vector takes only 5 minutes and yields more than 99% recombinant clones.

Features

  • Fast—PCR cloning in only 5–10 minutes.
  • High efficiency— >99% positive clones.
  • No cloning background with the positive selection pJET1.2 vector.
  • Economical—eliminates the need for expensive blue/white screening.

Learn more

pJET1.1/blunt vector map
Figure 4. pJET1.2/blunt vector map.