Seamlessly switch between a trap heart-cut 2D-LC system and a dual LC system using the innovative Thermo Scientific Vanquish Simple Switch 2D-LC System. This two-dimensional LC (LC-LC) system is an innovative, all-in-one system that uses the novel Thermo Scientific Vanquish Dual Split Sampler to enable users to seamlessly switch between both system capabilities without re-plumbing. Simply decide which task needs to be performed and this system supplies the confidence and productivity you need.
The unique system configuration allows you to run both trap-based 2D-LC for difficult samples and switch to a dual LC system that uses two independent 1D flow paths to run two analyses, either identical or not, on a single system without re-plumbing.
Run sensitive LC-LC methods by enriching the fractionated analytes on a trap column to enable low-concentration detection and prevent solvent incompatibility between detection methods; or run two complementary assays simultaneously on two separate flow paths to double throughput.
The system enables enrichment of low-abundant analytes and removal of diluting or disturbing solvents from the eluent by trapping and pre-concentrating the analytes of interest on a trap column to increase sensitivity when used as a 2D-LC instrument.
The second-dimension pump provides the flow for solvent modulation, to address solvent incompatibility between UV and MS methods or mobile phase incompatibility between different column chemistries to support multiple combinations of 1D and 2D methods.
The modularity of the Vanquish LC systems makes it easy to build a system to best meet your application requirements with the flexibility to upgrade from a standard HPLC instrument to a more advanced configuration when you need to address more challenging analyses.
The Vanquish Simple Switch 2D-LC system is fitted with Thermo Scientific Viper fingertight fittings, which support near-zero dead volume connections and enable sharper peaks and tool-free setup.
Our unique Vanquish Simple Switch 2D-LC system allows you to simply switch between a trap-based 2D-LC or dual LC.
This flow scheme illustrates how the three six-port valves can be configured to run the system for 2D-LC analysis with two columns with a trap column in series, or as a dual LC system with two columns in parallel.
All-in-one system: LC-LC system with trap and solvent modulation (left) OR Dual LC system with two independent ¹D flow path in one system (right).
The table below provides an overview of the Vanquish Simple Switch 2D-LC system specifications for standard setups. Specifications may differ based on the specific system components selected. See detailed Component Specifications for more information.
Category | Vanquish Simple Switch 2D-LC System |
System pressure, maximum | 1000 or 1500 bar, depends on system configuration |
Flow range | 0–5 or 0-8 mL/min, depends on pumps selected |
Pump options (default gradient delay volume) | Binary (35, 200µL) Delay volume depends on pump(s) selected |
Biocompatible | Yes |
pH range | 2–12, chloride concentration up to 1 mol/L |
System design | Modular |
Touchscreen user interface display compatible (optional) | Yes, depends on system configuration |
Solvent monitoring system compatible (optional) | Yes, depends on system configuration |
Customizable gradient delay volume to simplify method transfer | Yes, with metering device |
SmartInject technology for maximum injection precision and improved column lifetime | Yes |
Injection volume range | Standard: 0.01-25 µL |
Sample cooling | Yes, 4-40°C |
Sample capacity (standard) |
4 racks of 54 vials (≤ 1.5 mL) each, other rack formats available |
Sample extension available (optional) | Yes, with Vanquish Charger |
Column compartment thermostatting | Yes, 5-120°C |
Column compartment pre-heater |
Active and passive |
Column compartment post-column cooler | Yes |
Compatible Detectors | Vanquish Charged Aerosol Detector Vanquish Diode Array Detector Vanquish Fluorescence Detector Vanquish Multiple Wavelength Detector Vanquish Variable Wavelength Detector Refractive Index Detector Mass Spectrometer |
Standard Vanquish Simple Switch 2D-LC systems are made up of the following components. Download the associated specifications sheet for more detail on each component.
Vanquish Horizon Simple Switch 2D-LC System | Vanquish Flex Simple Switch 2D-LC System |
|
Pump
|
2 Vanquish Binary Pump H |
2 Vanquish Binary Pump F Note: Binary pump recommended as ²D pump |
Autosampler
|
Vanquish Split Sampler HT | Vanquish Split Sampler FT |
Extended sample capacity (optional)
|
Vanquish Charger (optional) |
|
Column compartment
|
Vanquish Column Compartment H | |
Virtually zero dead volume system connections
|
Viper UHPLC Fittings |
|
Detectors
|
Visit our HPLC and UHPLC Detectors page |