Giving excellent signal-to-noise performance and a wide dynamic range, the Thermo Scientific Diode Array Detectors employ a variety of technologies to allow you the flexibility to choose the right solution for your application.
Thermo Scientific Vanquish Diode Array Detectors (DADs) are designed for the highest performance, reliability and flexibility. Detect trace analytes next to main compounds due to a wide dynamic range and a low limit of detection. A wide portfolio of flow cells allows you to find the perfect match to your application needs.
Diode Array Detector HL | Diode Array Detector FG | |
---|---|---|
Wavelength range | 190 –680 nm | 190 –800 nm (with standard deuterium and tungsten lamp) |
Pixel resolution | 0.5 nm | 0.6 nm |
Number of signal channels | 10 + 3D field | 10 + 3D field |
Data collection rate | 200 Hz | 250 Hz |
Noise | <±3 μAU at 230 nm | <±6 μAU at 254 nm |
Drift | <0.5 mAU/h at 230 nm | <1 mAU at 254 nm |
Linearity | <5% at 2.0 AU | <5% at 2.2 AU |
Supporting both HPLC and UHPLC applications with eight channels of single-wavelength data acquisition, a 1024-element diode array, and the excellent noise and drift performance of a forward-optics detector.
DAD-3000 Diode Array Detector | Economical 100 Hz data collection rate choice for laboratories on a limited budget. |
---|---|
DAD-3000 RS Rapid Separation Diode Array Detector | Employing a 200 Hz data collection rate that is ideal for method development laboratories that need to capture full spectral information from novel compounds in narrow, RS peaks. |
Thermo Scientific Vanquish Diode Array Detectors (DADs) are designed for the highest performance, reliability and flexibility. Detect trace analytes next to main compounds due to a wide dynamic range and a low limit of detection. A wide portfolio of flow cells allows you to find the perfect match to your application needs.
Diode Array Detector HL | Diode Array Detector FG | |
---|---|---|
Wavelength range | 190 –680 nm | 190 –800 nm (with standard deuterium and tungsten lamp) |
Pixel resolution | 0.5 nm | 0.6 nm |
Number of signal channels | 10 + 3D field | 10 + 3D field |
Data collection rate | 200 Hz | 250 Hz |
Noise | <±3 μAU at 230 nm | <±6 μAU at 254 nm |
Drift | <0.5 mAU/h at 230 nm | <1 mAU at 254 nm |
Linearity | <5% at 2.0 AU | <5% at 2.2 AU |