Landfill Gas Monitoring and Collection

Explore our landfill gas solutions

Monitor, manage, and collect landfill gas

QED Environmental products are designed to monitor, manage, and collect landfill gas and leachate extraction to best control gas production and collection plus monitor fugitive gas emissions.

 

Our selection includes leachate pumps, control systems, gas collection headworks, and both fixed and portable gas monitoring systems. All items are intrinsically safe, including our range of electric pumps.


Landfill gas monitoring

All Geotech gas monitors are intrinsically safe and can be customized to suit budget and site requirements.  The analysers can be configured to include GPS and sensors of varying ranges of H2S, CO or H2 compensated CO to determine the presence of underground fires as well as H2 and NH3.

 

GA5000

GEM5000

BIOGAS 5000

BIOGAS 3000

  GA5000 gas monitor GEM5000 gas monitor BIOGAS 5000 gas monitor
  Monitor peripheral wells for fugitive gases with an option to measure flow via an internal flow cell Monitor gas production wells with elevated concentrations higher flow rates and increased temperatures Measure the conditions of a digester Stand alone or integrate into an onsite data collection systems and co-generation of power system from waste
Type Portable Portable Portable Fixed

CH4, CO2, O2

Y Y Y Y
H2S Y Y Y Y
CO or H2 comp CO Y Y Y Y
H2 Y Y Y Y
NH3 Y Y Y X
Internal Flow L/hour Y X X X
Flow M3/hour with additional accessories Y Y Y X
User calibration Y Y Y Y
Data management Y Y Y X

Accessories for Geotech gas analysers

 

Catalog No. Description
GTIGF5.1 Soft carry case for portable 5000 series
GTIGF5.4 Anemometer for measuring high flows in 5000 series
GTIGF5.2 Temperature Probe for Geotech 5000 Series
GTIPITOT Pitot Tube for GEM series gas analysers 
GTIGA4.9 In-line water trap elements 10 pcs
GTIGA6.5 H2S/VOC Hydrocarbon filter (Pack of 5)
GTIGFUSB USB Communications Lead 5000 Series
GTIGF3.9 Battery charger for portable 5000 series

 

Laser One Methane Selective Analyser

Laser One is a single gas analyser specifically designed to measure methane (CH4) from 1 PPM to % range using tunable laser diode technologies.


Leachate extraction

QED Environmental products are designed to aid groundwater extraction of leachate to open areas for gas production and to mitigate leachate moving off site and impacted groundwater.

 

Products range from total fluid pumping with option of both pneumatic and electric for high flow requirements. These products are all designed to function in some of the harshest environments, making sure it is done by staying intrinsically safe. The amount of different options available make QED the best choice in the market.

 

AP range

Slider pumps

ESP electric pumps

  AP range
ESP electric pump
  The Autopump range are an air-driven pump with variants for the harshest conditions. They are a robust pump that is easy to disassemble and clean Constructed from stainless steel and has a side mounted tube to control liquid via the L370 liquid level controller when coupled to an L360 pneumatic controller. Constructed of stainless steel and an external trash screen made of a durable polyethylene and designed for many applications. Designed for high flow applications
Pneumatically operated Y Y Y
Pump diameter 2 in to 4 in 4 in 4 in to 12 in
Angled wells X Y Y
Budget $ $$ $$$

*ESP pumps include outer screen to protect from waste pumps require external power.
** Slider pumps require external controllers such as L360 or C100M.
***Slider pumps can have level control via L370.

 

AP4+ Autopump range

 

All pumps can handle temperatures of 180º F. Special models available for severe applications, including high temperatures, high viscosity and corrosive conditions.

 

4' Long AP4+/B

4’ Short AP4+/B

4’ Low Drawdown AP4+/B

4’ Long AP4+/T

4’ Short AP4+/T

4’ Low Drawdown AP4+/T

Fluid inlet Bottom Bottom Bottom Top Top Top
Diameter 9.1 cm OD 9.1 cm OD 9.1 cm OD 9.1 cm OD 9.1 cm OD 9.1 cm OD
Length 131 cm 104 cm 71 cm 144 cm 110 cm 78 cm
Max flow 69 Lpm 49 Lpm 26.5 Lpm 38 Lpm 34 Lpm 24 Lpm
Max depth 76 m 76 m 76 m 76 m 76 m 76 m
Actuation level 98 cm 68 cm 39 cm 135 cm 106 cm 70 cm

Gas extraction

QED Environmental gas collection headworks

 

QED has a large variety of well heads designed for different sizes and material construction types. These well heads are designed to take a selection of the QED range of pumps or others.

 

Well heads are also designed in such a way that allows for gas extraction over a range of flow control options, incorporating orifice plates and their patented flow control valve to give an accurate flow over its opening range.

Quick-Change Orifice Plate Wellhead

The QED quick change orifice plate well head is comprised of a well cap, gas riser, and precision control valve. The high visibility well head allows for pumping with a level indicator and perforations for manual dipping ports.

  • The well head has options for vertical and horizontal alignments.
  • The horizontal configuration is ideal for sump installation to decrease vandalism.  
  • The well cap also has the option for simultaneous leachate and gas extraction, level indication, and manual dipping ports.

Precision flow control

The QED Precision flow valve with an orifice plate option includes gas sampling ports and flow ports. The main body also allows for manual dipping or the addition of a pressure transducer via gland.

The control valve allows for improved linear flow control over the entire range of valve movements compared to traditional valving systems such as gate and ball valves.