Search Thermo Fisher Scientific
- Contact Us
- Quick Order
-
Don't have an account ? Create Account
Search Thermo Fisher Scientific
The RapidFinder™ STEC Detection Workflow is a complete, validated screening and confirmation system for E. coli O157:H7 and the six non-O157 STEC (Shiga toxigenic E. coli).
For beef producers, rapid and accurate results when screening products for STEC and other pathogens can bring substantial economic benefits.
Current reference methods for detecting STEC in beef samples are accurate and sensitive but can be slow and labor-intensive. Alternative rapid methods can show reduced accuracy and often require large volumes of proprietary media, making them a risky and uneconomic option.
The Applied Biosystems™ RapidFinder™ STEC Detection Workflow enables screening for E. coli O157:H7 and six strains of Shiga toxigenic E. coli—the Big 6 STECs—in as few as 12 hours, providing a rapid, validated workflow for STEC detection in raw ground beef and raw beef trim.
The RapidFinder STEC Detection Workflow is a two-stage real-time PCR method, designed to accurately detect and confirm the presence of E. coli O157:H7 and the 'Big 6' serogroups of non-O157 STEC (serogroups O26, O45, O103, O111, O121 & O145), defined by the USDA Food Safety and Inspection Service (FSIS) as adulterants in the American beef industry.
The RapidFinder STEC Detection System has two AOAC Research Institute (AOAC-RI) Performance Tested MethodsSM certified workflow options that greatly reduce the sample enrichment time and volume, adding a second layer of specificity for sero-group specific detection.
Workflow 1, ~12 hours, suitable for laboratories running a high test throughput
Automated sample preparation is used on the Applied Biosystems™ MagMax™ Express-96 Magnetic Particle Processor and Applied Biosystems™ PrepSEQ™ Nucleic Acid Extraction Kit, or the Thermo Scientific™ KingFisher™ Flex Purification System, KingFisher with 96 Deep-well Head. Up to 96 samples can be processed together, from enrichment to RapidFinder STEC Screening Assay results, in approximately 12 hours. One additional hour is required for the RapidFinder STEC Confirmation Assay results.
Workflow 2, ~18 hours, ideal for lower test throughput
The Applied Biosystems™ PrepSEQ™ Rapid Spin Sample Preparation Kit – Extra Clean with Proteinase K is used for manual PCR sample preparation with spin columns, providing screening release in approximately 18 hours.
Learn more about the RapidFinder STEC Detection Workflow, and other products in our range for STEC testing, by reviewing the resources below or contact us to speak to one of our specialists.
Empower your operations with rapid reporting and detect foodborne pathogens and other targets quickly and accurately. Our Food PCR Test Method Selection Guide helps you to choose your workflow solution by target and sample type.
Related Products | Order code |
---|---|
Applied Biosystems™ PrepSEQ™ Nucleic Acid Extraction Kit | 4428176 |
PrepSEQ Rapid Spin Sample Preparation Kit – Extra Clean with Proteinase K | |
PrepSEQ Nucleic Acid Extraction Kit* | |
PrepSEQ Nucleic Acid Extraction Kit* | |
RapidFinder STEC Screening Assay | |
RapidFinder STEC Confirmation Assay | |
RapidFinder STEC Screening Assay Starter Kit – with PrepSEQ Nucleic Acid Extraction Kit | 4480467 |
7500 Fast Instrument Package, Laptop** | A30299 |
7500 Fast Instrument Package, Desktop** | A30304 |
RapidFinder Express v2.0 and SDS 1.4.2 Software for 7500 Fast Instrument |
*Used with the MagMax Express 96 Deep Well Processor or the Thermo Scientific™ KingFisher™ Flex Purification System, KingFisher with 96 Deep-well Head
** Includes: 7500 Fast instrument, Computer, RapidFinder Express v2.0 and SDS 1.4.2 Software, capping tool, Precision plate holder, Calibration kits and Block balance tubes