Search Thermo Fisher Scientific
- Order Status
- Quick Order
-
Don't have an account ? Create Account
Search Thermo Fisher Scientific
Choose between Heratherm Microbiological Incubators and Heratherm Refrigerated Incubators.
Microbiological incubators, also called "heat-only," or "standard" incubators, have heating elements and can provide incubation temperatures that are above ambient temperature only. If the laboratory has an ambient of about 22°C, they can only address incubation temperatures above about 27°C or even 30°C. Temperature ranges vary by model.
Refrigerated incubators, also called "cooling" incubators have cooling and heating and can provide a wider temperature range. They can offer temperatures close to ambient or even below ambient. They usually also cover the incubation temperature range above ambient, just as the microbiological or "heat-only" incubators do.
Heratherm Advanced Protocol Security Incubators Ensure outstanding sample safety with multiple alarms and a 140℃ decontamination cycle. |
Heratherm Advanced Protocol Incubators Attain excellent heating consistency, well suited for a variety of drying applications. |
Heratherm General Protocol Incubators Benchtop and floor model versions available for routine usage. |
Temperature Range |
||
Ambient+5 to +105°C |
Ambient+5 to +105°C |
Ambient +5 to +75°C |
Convection technology |
||
Benchtop – Dual Large capacity - Mechanical |
Dual |
Gravity |
Temperature performance |
||
Best |
Best |
Good |
Alarms |
||
Automatic over-temperature Automatic under temperature Door alarm |
Automatic over-temperature |
Automatic over-temperature |
Timer |
||
Weekly/daily/real time |
Weekly/daily/real time |
on/off |
Additional sample security features |
||
Certified decontamination cycle* Lockable doors Connection for temperature sensor |
– – |
– – |
Ordering information |
||
*Verified by independent testing facility (IBFE 9/2010)
NOTE: All figures in tables are typical average values for series devices, based on factory standard following norm Din12880. Please contact us for certification information or IQ/OQ documents.
Heratherm Refrigerated Incubator, benchtop model
Ideally suited for a personalized workspace or crowded lab. |
Heratherm Refrigerated Incubator, IMP400 floor model
Reach and maintain the precise ambient temperatures you need for reliable results while maintaining efficient energy usage. |
Heratherm Compact Microbiological Incubators
Ideally suited for a personalized workspace or crowded lab. |
Temperature range |
|
|
+5 to +70°C |
+5 to +70°C |
+18 to + 40°C |
Convection technology |
|
|
Peltier |
Peltier |
Peltier with Mechanical |
Temperature performance |
|
|
Best |
Best |
Good |
Number of shelf positions |
|
|
19 |
39 |
3 |
Energy consumption at 20 °C |
|
|
80 Wh/h |
150 Wh/h |
14 Wh/h |
Ordering information |
|
|
NOTE: All figures in this table are typical average values for series devices, based on factory standard following norm DIN12880. Please contact us for certification information or IQ/OQ documents.
For Laboratory Use.