Carboy-20-25L

Nalgene 20L (5ga) and 25L (6.5ga) Nalgene carboys go the extra mile containing your higher-volume lab solutions. Their rugged construction will hold up to the most rigorous lab and field applications. Made only from the highest-quality laboratory, pharmaceutical and food-grade plastic materials; no unnecessary additives to contaminate your valuable reagents, research or production materials. Choose from a wide variety of shapes and plastic materials to find the carboy that best meets your application needs.  

  • Polypropylene (PP), polypropylene copolymer (PPCO), high density polyethylene (HDPE) and low density polyethylene (LDPE) carboys are chemically compatible with a wide range of lab reagents including most acids, bases, alcohols, aldehydes, esters, and aliphatic hydrocarbons. Choose fluorinated high density polyethylene (FLPE) for enhanced compatibility with organic solvents. 
  • Polypropylene, polypropylene copolymer and polycarbonate (PC) materials are autoclavable.
  • The polyethylenes and polycarbonate are ideal choices for low-temperature applications.

For chemical compatibility ratings by specific chemical and application temperature, consult the  Nalgene Chemical Resistance Guide, or request a copy of the printed wall chart. Nalgene carboys are made only from high-quality laboratory-grade resin materials that comply with a number of regulatory specifications including: USP Class VI, EP monographs, EU food-contact directives, CONEG, RoHS, CA Prop 65, SARA Title III Sec. 313, and 21 CFR pt 177 for food contact. For regulatory claims  and certifications applicable to specific Nalgene carboys, please contact  Nalgene Regulatory Support.

For help selecting the Thermo Scientific Nalgene carboy that's perfect for your lab applications, use our online selection guide or for personal assistance, contact the  Nalgene technical support team.


Narrow-Mouth Round Carboy with Spigot (2319-0050, 8319-0050 APAC)Narrow-Mouth Round Carboy (2250-0050, 8250-0050 in APAC)Wide-Mouth Round Carboy (2235-0050)Narrow-Mouth Round Carboy with Tubulation  2301-0020)Rectangular Carboy with Spigot (2321-0050)Rectangular Carboy (2212-0050)
Dispensing lab water and reagents.  Compatible with sterilization by autoclavingLiquid storage and shipping.  Applications where autoclaving is required.Liquid storage where autoclaving is required. Wide  mouth allows easy access for filling and cleaningFor gravity fed liquid dispensing through tubing.  Applications where autoclaving is required.Dispensing lab water and reagents.  Excellent choice for space efficient reagent banks. AutoclavableSpace-efficient storage for large-volume lab solutions where autoclaving is required
PP with white PP closure/TPE gasket, PP spigotPP with white PP closure/TPE gasketPPCO with white PP closurePP with white PP closure/TPE gasketPPCO with white PP closure, PP spigotPPCO with white PP closure
RoundRoundRoundRoundRectangular Rectangular 
Milky white translucentMilky white translucentMilky white translucentMilky white translucentMilky white translucentMilky white translucent
20L (5ga)20L (5ga)20L (5ga)20L (5ga)20L (5ga)20L (5ga)
Narrow mouth Narrow mouth Wide mouthNarrow mouth Wide mouthWide mouth
SpigotNo drainNo drainTubing adapter portSpigotNo drain
Leakproof*Leakproof*Leakproof*Leakproof*Leakproof*Leakproof*
Temp range 0°C to 135°CTemp range 0°C to 135°CTemp range -40°C to 121°CTemp range 0°C to 135°CTemp range -40°C to 121°CTemp range -40°C to 121°C
AutoclavableAutoclavableAutoclavableAutoclavableAutoclavableAutoclavable
Non-sterileNon-sterileNon-sterileNon-sterileNon-sterileNon-sterile
Graduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallons
Molded-in shoulder handlesMolded-in shoulder handlesMolded-in shoulder handlesMolded-in shoulder handlesStainless steel handle and 20L w/molded-in gripStainless steel handle and 20L w/molded-in grip
Complies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food use
BPA-freeBPA-freeBPA-freeBPA-freeBPA-freeBPA-free
Phthalate-freePhthalate-freePhthalate-freePhthalate-freePhthalate-freePhthalate-free

General chemical compatibility

 Narrow-mouth Round Carboy with Spigot (2319-0020, 8319-0020 APAC)Narrow-Mouth Round Carboy (2250-0020, 8250-series in APAC)Wide-Mouth Round Carboy (2235-0020)Narrow-Mouth Round Carboy with Tubulation Port (2301-0020)Rectangular Carboy with Spigot (2321-0020)Rectangular Carboy (2212-0020)
Acids, dilute or weakEEEEEE
Acids^ strong, concentratedGGGGGG
Alcohols, aliphaticEEEEEE
AldehydesGGGGGG
Bases/alkaliEEEEEE
EstersGGGGGG
Hydrocarbons, aliphaticGGGGGG
Hydrocarbons, aromaticNNNNNN
Hydrocarbons, halogenated NNNNNN
Ketones, aromaticNNNNNN
Oxidizing agents, strongFFFFFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to  Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.

Footnote:
1. HDPE and LDPE are acceptable for: Nonacid, aqueous products; may contain salt, sugar or both (pH above 5.0). Dairy products and modifications; oil-in-water emulsions, high or low fat. Moist bakery products with surface containing no free fat or oil. Dry solids with the surfaces containing no free fat or oil (no end-test required) and under all conditions as described in Table 2 of FDA Regulation 177.1520 except condition A - high temperature sterilization (e.g., over 100°C / 212°F)

*The term “leakproof” applies to Thermo Scientific Nalgene products that meet the following criteria: a) Bottle/flask/funnel closure systems with closures smaller than 100mm, after they are filled with water, inverted, withstand air pressure of 2psig for 2 minutes, and no water escapes;. b) Bottle/funnel/flask closure systems of larger than 100mm after they are filled with water, inverted for 15 minutes, and no water escapes. Note: these tests, using other liquids, may not yield the same results. To ensure safe usage, customers are advised to test Thermo Scientific Nalgene bottles and closures under conditions of their planned applications. Thermo Scientific Nalgene products are leakproof at ambient temperature and pressure when used with their Nalgene closures.

^Except for oxidizing acids, see "Oxidizing acids, strong."

Rectangular Carboy with Spigot
(2320-0050)
Rectangular Carboy
(2211-0050)
Heavy-Duty Rectangular Carboy
(2214-0050)
Rectangular Carboy with Tubulation (2303-0050)Single Use Sterile Carboy
(342289-series)
Dispensing lab water and reagents. Excellent choice for space efficient reagent banks.Space-efficient storage  for large volume lab solutions. Space-saving, extra-durable design for storing and shipping large volume lab reagents and other liquids. Dispensing media, DI water and other lab reagents by gravity feed. Rectangular design optimizes shelf spaceSupplied sterile for one-time use, the high-density polyethylene vessels are ideal for storing sterile fluids and pharmaceutical/biotech products.
HDPE with PP spigot and white PP closureHDPE with white PP  closureHDPE with white PP closureHDPE with white PP  closureHDPE with white PP  closure
Rectangular Rectangular Rectangular Rectangular Round
Milky white translucentMilky white translucentMilky white translucentMilky white translucentMilky white translucent
20L (5ga)20L (5ga)20L (5ga)20L (5ga)20L (5ga)and 33L (8.7ga)
Wide mouthWide mouthNarrow mouth Wide mouthNarrow mouth 
SpigotNo drainNo drainTubing adapter portNo drain
Leakproof*Leakproof*Leakproof*Leakproof*Leakproof*
Temp range -100°C to 120°CTemp range -100°C to 120°CTemp range -100°C to 120°CTemp range -100°C to 120°CTemp range -100°C to 120°C
Not autoclavableNot autoclavableNot autoclavableNot autoclavableNot autoclavable
Non-sterileNon-sterileNon-sterileNon-sterileSterile
Graduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsNo graduations
Stainless steel handleStainless steel handle and 20L w/molded-in gripMolded-in handleStainless steel handle and molded-in gripStainless steel handle sold separately/molded-in shoulder handle
Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1
BPA-freeBPA-freeBPA-freeBPA-freeBPA-free
Phthalate-freePhthalate-freePhthalate-freePhthalate-freePhthalate-free

General chemical compatibility

 Rectangular Carboy with Spigot 
(2320-0050)
Rectangular Carboy 
(2211-0050)
Heavy-Duty Rectangular Carboy 
(2214-0050)
Rectangular Carboy with Tubulation
(2303-0050)
Single Use Sterile Carboy 
(342289-series)
Acids, dilute or weakEEEEE
Acids^ strong, concentratedGGGGG
Alcohols, aliphaticEEEEE
AldehydesGGGGG
Bases/alkaliEEEEE
EstersGGGGG
Hydrocarbons, aliphaticGGGGG
Hydrocarbons, aromaticNNNNN
Hydrocarbons, halogenated NNNNN
Ketones, aromaticNNNNN
Oxidizing agents, strongFFFFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.

Footnote:

1. HDPE and LDPE are acceptable for: Nonacid, aqueous products; may contain salt, sugar or both (pH above 5.0). Dairy products and modifications; oil-in-water emulsions, high or low fat. Moist bakery products with surface containing no free fat or oil. Dry solids with the surfaces containing no free fat or oil (no end-test required) and under all conditions as described in Table 2 of FDA Regulation 177.1520 except condition A - high temperature sterilization (e.g. over 100° C / 212° F)

*The term “leakproof” applies to Thermo Scientific Nalgene products that meet the following criteria: a) Bottle/flask/funnel closure systems with closures smaller than 100mm, after they are filled with water, inverted, withstand air pressure of 2psig for 2 minutes, and no water escapes;. b) Bottle/funnel/flask closure systems of larger than 100mm after they are filled with water, inverted for 15 minutes, and no water escapes. Note: these tests, using other liquids, may not yield the same results. To ensure safe usage, customers are advised to test Thermo Scientific Nalgene bottles and closures under conditions of their planned applications. Thermo Scientific Nalgene products are leakproof at ambient temperature and pressure when used with their Nalgene closures.

^Except for oxidizing acids, see "Oxidizing acids, strong."

Narrow-Mouth Round Carboy with Spigot
(2318-series,  8318-series in APAC)
Narrow-Mouth Round Carboy
(2210-series, 8210-series in APAC)
Narrow-Mouth Round Carboy with Tubulation Port
(2302-0050)
Wide-Mouth Round Carboy
(2234-0050)
Classic DI water and lab reagent dispenserClassic DI water and reagent reservoirFor gravity fed liquid dispensing through tubingWide mouth reagent reservoir provides easy access and cleaning
LDPE carboy with white PP closure and PP spigotLDPE carboy with white PP closureLDPE carboy with white PP closureLDPE carboy with white PP closure
RoundRoundRoundRound
Milky white translucentMilky white translucentMilky white translucentMilky white translucent
20L (5.5ga) and 25L (6.5ga)20L (5ga) and 25L (6.5ga)20L (5ga)20L (5ga)
Narrow mouth Narrow mouth Narrow mouth Wide mouth
SpigotNo drainTubing adapter portNo drain
Leakproof*Leakproof*Leakproof*Leakproof*
Temp range
-76°C to 70°C
Temp range
-76°C to 70°C
Temp range
-76°C to 70°C
Temp range
-76°C to 70°C
Not autoclavableNot autoclavableNot autoclavableNot autoclavable
Non-sterileNon-sterileNon-sterileNon-sterile
Graduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallons
Molded-in shoulder handlesMolded-in shoulder handlesMolded-in shoulder handlesMolded-in shoulder handles
Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1
BPA-freeBPA-freeBPA-freeBPA-free
Phthalate-freePhthalate-freePhthalate-freePhthalate-free

General chemical compatibility

 Narrow-Mouth Round Carboy with Spigot
(2318-series,  8318-series in APAC)
Narrow-Mouth Round Carboy 
(2210-series, 8210-series in APAC)
Narrow-Mouth Round Carboy with Tubulation Port 
(2302-0050)
Wide-Mouth Round Carboy 
(2234-0050)
Acids, dilute or weakEEEE
Acids^ strong, concentratedGGGG
Alcohols, aliphaticEEEE
AldehydesGGGG
Bases/alkaliEEEE
EstersGGGG
Hydrocarbons, aliphaticGGGG
Hydrocarbons, aromaticNNNN
Hydrocarbons, halogenated NNNN
Ketones, aromaticNNNN
Oxidizing agents, strongFFFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.
Narrow-Mouth Round Clearboy with Spigot (2317-0050)Narrow-Mouth Round Clearboy Carboy
(2251-0050)
Wide-Mouth Rectangular Clearboy with Spigot
(2322-0050)
Wide-Mouth Rectangular Clearboy (DS2213-0050)
Dispensing lab media and non-aggressive aqueous lab reagents where a clear view of contents is desired. Compatible with sterilization.Mixing, storing and shipping lab media and non-aggressive aqueous  reagents where a clear view of contents..  Dispensing lab media and non-aggressive aqueous lab reagents where a clear view of contents is desired.  Rectangular shape optimized shelf space.Storing lab media and non-aggressive aqueous lab reagents where a clear view of contents is desired. Rectangular shape optimizes shelf space.
PC with white PP closure/TPE gasket and PP spigotPC with white PP closure/TPE gasket PC with white PP closure and PP spigotPC with white PP closure 
RoundRoundRectangularRectangular
ClearClearClearClear
20L (5ga)20L (5ga)20L (5ga)20L (5ga)
Narrow mouth Narrow mouth Wide mouthWide mouth
SpigotNo drainSpigotNo drain
Leakproof*Leakproof*Leakproof*Leakproof*
Temp range -135°C to 135°CTemp range -135°C to 135°CTemp range -135°C to 135°CTemp range -135°C to 135°C
AutoclavableAutoclavableAutoclavableAutoclavable
Non-sterileNon-sterileNon-sterileNon-sterile
Graduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallons
No handlesNo handlesStainless steel handleStainless steel handle
Complies with Part 21 CFR 177.1580 for food useComplies with Part 21 CFR 177.1580 for food useComplies with Part 21 CFR 177.1580 for food useComplies with Part 21 CFR 177.1580 for food use
Contains BPAContains BPAContains BPAContains BPA
Phthalate-freePhthalate-freePhthalate-freePhthalate-free

General chemical compatibility

 Narrow-Mouth Round Clearboy with Spigot (2317-0050)Narrow-Mouth Round Clearboy Carboy
(2251-0050)
Wide-Mouth Rectangular Clearboy with Spigot
(2322-0050)
Wide-Mouth Rectangular Clearboy (DS2213-0050)
Acids, dilute or weakEEEE
Acids^ strong, concentratedNNNN
Alcohols, aliphaticGGGG
AldehydesFFFF
Bases/alkaliNNNN
EstersNNNN
Hydrocarbons, aliphaticGGGG
Hydrocarbons, aromaticNNNN
Hydrocarbons, halogenated NNNN
Ketones, aromaticNNNN
Oxidizing agents, strongFFFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.

Footnote:

1. HDPE and LDPE are acceptable for: Nonacid, aqueous products; may contain salt, sugar or both (pH above 5.0). Dairy products and modifications; oil-in-water emulsions, high or low fat. Moist bakery products with surface containing no free fat or oil. Dry solids with the surfaces containing no free fat or oil (no end-test required) and under all conditions as described in Table 2 of FDA Regulation 177.1520 except condition A - high temperature sterilization (e.g. over 100° C / 212° F)

*The term “leakproof” applies to Thermo Scientific Nalgene products that meet the following criteria: a) Bottle/flask/funnel closure systems with closures smaller than 100mm, after they are filled with water, inverted, withstand air pressure of 2psig for 2 minutes, and no water escapes;. b) Bottle/funnel/flask closure systems of larger than 100mm after they are filled with water, inverted for 15 minutes, and no water escapes. Note: these tests, using other liquids, may not yield the same results. To ensure safe usage, customers are advised to test Thermo Scientific Nalgene bottles and closures under conditions of their planned applications. Thermo Scientific Nalgene products are leakproof at ambient temperature and pressure when used with their Nalgene closures.

^Except for oxidizing acids, see "Oxidizing acids, strong."

Fluorinated Carboy (2097-0050)Fluorinated Carboy with Spigot
(DS2327-0050)
Storage for solvents and other organic solutions Space-efficient dispensing for non-flammable solvents and other organic solutions 
FLPE with white PP closureFLPE with white PP  closure and fluoropolymer spigot
RoundRectangular 
Milky white translucent, yellowish tint due to fluorination processMilky white translucent, yellowish tint due to fluorination process
20L (5ga)20L (5ga)
Narrow mouthWide mouth
No drainSpigot
Leakproof*Leakproof*
Temp range -100°C to 120°CTemp range -100°C to 120°C
Not autoclavableNot autoclavable
Non-sterileNon-sterile
Graduated in liters and gallonsGraduated in liters and gallons
Molded-in shoulder handleStainless steel handle
Complies with Part 21 CFR 177.1615 for food use1Complies with Part 21 CFR 177.1615 for food use1
BPA-freeBPA-free
Phthalate-freePhthalate-free

General chemical compatibility

 Fluorinated Carboy (2097-0050)Fluorinated Carboy with Spigot 
(DS2327-0050)
Acids, dilute or weakEE
Acids^ strong, concentratedGG
Alcohols, aliphaticEE
AldehydesGG
Bases/alkaliFF
EstersGG
Hydrocarbons, aliphaticEE
Hydrocarbons, aromaticEE
Hydrocarbons, halogenated GG
Ketones, aromaticGG
Oxidizing agents, strongFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.

Footnote:

1. HDPE and LDPE are acceptable for: Nonacid, aqueous products; may contain salt, sugar or both (pH above 5.0). Dairy products and modifications; oil-in-water emulsions, high or low fat. Moist bakery products with surface containing no free fat or oil. Dry solids with the surfaces containing no free fat or oil (no end-test required) and under all conditions as described in Table 2 of FDA Regulation 177.1520 except condition A - high temperature sterilization (e.g. over 100° C / 212° F)

*The term “leakproof” applies to Thermo Scientific Nalgene products that meet the following criteria: a) Bottle/flask/funnel closure systems with closures smaller than 100mm, after they are filled with water, inverted, withstand air pressure of 2psig for 2 minutes, and no water escapes;. b) Bottle/funnel/flask closure systems of larger than 100mm after they are filled with water, inverted for 15 minutes, and no water escapes. Note: these tests, using other liquids, may not yield the same results. To ensure safe usage, customers are advised to test Thermo Scientific Nalgene bottles and closures under conditions of their planned applications. Thermo Scientific Nalgene products are leakproof at ambient temperature and pressure when used with their Nalgene closures.

^Except for oxidizing acids, see "Oxidizing acids, strong."

Narrow-Mouth Round Carboy with Spigot (2319-0050, 8319-0050 APAC)Narrow-Mouth Round Carboy (2250-0050, 8250-0050 in APAC)Wide-Mouth Round Carboy (2235-0050)Narrow-Mouth Round Carboy with Tubulation  2301-0020)Rectangular Carboy with Spigot (2321-0050)Rectangular Carboy (2212-0050)
Dispensing lab water and reagents.  Compatible with sterilization by autoclavingLiquid storage and shipping.  Applications where autoclaving is required.Liquid storage where autoclaving is required. Wide  mouth allows easy access for filling and cleaningFor gravity fed liquid dispensing through tubing.  Applications where autoclaving is required.Dispensing lab water and reagents.  Excellent choice for space efficient reagent banks. AutoclavableSpace-efficient storage for large-volume lab solutions where autoclaving is required
PP with white PP closure/TPE gasket, PP spigotPP with white PP closure/TPE gasketPPCO with white PP closurePP with white PP closure/TPE gasketPPCO with white PP closure, PP spigotPPCO with white PP closure
RoundRoundRoundRoundRectangular Rectangular 
Milky white translucentMilky white translucentMilky white translucentMilky white translucentMilky white translucentMilky white translucent
20L (5ga)20L (5ga)20L (5ga)20L (5ga)20L (5ga)20L (5ga)
Narrow mouth Narrow mouth Wide mouthNarrow mouth Wide mouthWide mouth
SpigotNo drainNo drainTubing adapter portSpigotNo drain
Leakproof*Leakproof*Leakproof*Leakproof*Leakproof*Leakproof*
Temp range 0°C to 135°CTemp range 0°C to 135°CTemp range -40°C to 121°CTemp range 0°C to 135°CTemp range -40°C to 121°CTemp range -40°C to 121°C
AutoclavableAutoclavableAutoclavableAutoclavableAutoclavableAutoclavable
Non-sterileNon-sterileNon-sterileNon-sterileNon-sterileNon-sterile
Graduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallons
Molded-in shoulder handlesMolded-in shoulder handlesMolded-in shoulder handlesMolded-in shoulder handlesStainless steel handle and 20L w/molded-in gripStainless steel handle and 20L w/molded-in grip
Complies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food useComplies with Part 21 CFR 177.1520 for food use
BPA-freeBPA-freeBPA-freeBPA-freeBPA-freeBPA-free
Phthalate-freePhthalate-freePhthalate-freePhthalate-freePhthalate-freePhthalate-free

General chemical compatibility

 Narrow-mouth Round Carboy with Spigot (2319-0020, 8319-0020 APAC)Narrow-Mouth Round Carboy (2250-0020, 8250-series in APAC)Wide-Mouth Round Carboy (2235-0020)Narrow-Mouth Round Carboy with Tubulation Port (2301-0020)Rectangular Carboy with Spigot (2321-0020)Rectangular Carboy (2212-0020)
Acids, dilute or weakEEEEEE
Acids^ strong, concentratedGGGGGG
Alcohols, aliphaticEEEEEE
AldehydesGGGGGG
Bases/alkaliEEEEEE
EstersGGGGGG
Hydrocarbons, aliphaticGGGGGG
Hydrocarbons, aromaticNNNNNN
Hydrocarbons, halogenated NNNNNN
Ketones, aromaticNNNNNN
Oxidizing agents, strongFFFFFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to  Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.

Footnote:
1. HDPE and LDPE are acceptable for: Nonacid, aqueous products; may contain salt, sugar or both (pH above 5.0). Dairy products and modifications; oil-in-water emulsions, high or low fat. Moist bakery products with surface containing no free fat or oil. Dry solids with the surfaces containing no free fat or oil (no end-test required) and under all conditions as described in Table 2 of FDA Regulation 177.1520 except condition A - high temperature sterilization (e.g., over 100°C / 212°F)

*The term “leakproof” applies to Thermo Scientific Nalgene products that meet the following criteria: a) Bottle/flask/funnel closure systems with closures smaller than 100mm, after they are filled with water, inverted, withstand air pressure of 2psig for 2 minutes, and no water escapes;. b) Bottle/funnel/flask closure systems of larger than 100mm after they are filled with water, inverted for 15 minutes, and no water escapes. Note: these tests, using other liquids, may not yield the same results. To ensure safe usage, customers are advised to test Thermo Scientific Nalgene bottles and closures under conditions of their planned applications. Thermo Scientific Nalgene products are leakproof at ambient temperature and pressure when used with their Nalgene closures.

^Except for oxidizing acids, see "Oxidizing acids, strong."

Rectangular Carboy with Spigot
(2320-0050)
Rectangular Carboy
(2211-0050)
Heavy-Duty Rectangular Carboy
(2214-0050)
Rectangular Carboy with Tubulation (2303-0050)Single Use Sterile Carboy
(342289-series)
Dispensing lab water and reagents. Excellent choice for space efficient reagent banks.Space-efficient storage  for large volume lab solutions. Space-saving, extra-durable design for storing and shipping large volume lab reagents and other liquids. Dispensing media, DI water and other lab reagents by gravity feed. Rectangular design optimizes shelf spaceSupplied sterile for one-time use, the high-density polyethylene vessels are ideal for storing sterile fluids and pharmaceutical/biotech products.
HDPE with PP spigot and white PP closureHDPE with white PP  closureHDPE with white PP closureHDPE with white PP  closureHDPE with white PP  closure
Rectangular Rectangular Rectangular Rectangular Round
Milky white translucentMilky white translucentMilky white translucentMilky white translucentMilky white translucent
20L (5ga)20L (5ga)20L (5ga)20L (5ga)20L (5ga)and 33L (8.7ga)
Wide mouthWide mouthNarrow mouth Wide mouthNarrow mouth 
SpigotNo drainNo drainTubing adapter portNo drain
Leakproof*Leakproof*Leakproof*Leakproof*Leakproof*
Temp range -100°C to 120°CTemp range -100°C to 120°CTemp range -100°C to 120°CTemp range -100°C to 120°CTemp range -100°C to 120°C
Not autoclavableNot autoclavableNot autoclavableNot autoclavableNot autoclavable
Non-sterileNon-sterileNon-sterileNon-sterileSterile
Graduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsNo graduations
Stainless steel handleStainless steel handle and 20L w/molded-in gripMolded-in handleStainless steel handle and molded-in gripStainless steel handle sold separately/molded-in shoulder handle
Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1
BPA-freeBPA-freeBPA-freeBPA-freeBPA-free
Phthalate-freePhthalate-freePhthalate-freePhthalate-freePhthalate-free

General chemical compatibility

 Rectangular Carboy with Spigot 
(2320-0050)
Rectangular Carboy 
(2211-0050)
Heavy-Duty Rectangular Carboy 
(2214-0050)
Rectangular Carboy with Tubulation
(2303-0050)
Single Use Sterile Carboy 
(342289-series)
Acids, dilute or weakEEEEE
Acids^ strong, concentratedGGGGG
Alcohols, aliphaticEEEEE
AldehydesGGGGG
Bases/alkaliEEEEE
EstersGGGGG
Hydrocarbons, aliphaticGGGGG
Hydrocarbons, aromaticNNNNN
Hydrocarbons, halogenated NNNNN
Ketones, aromaticNNNNN
Oxidizing agents, strongFFFFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.

Footnote:

1. HDPE and LDPE are acceptable for: Nonacid, aqueous products; may contain salt, sugar or both (pH above 5.0). Dairy products and modifications; oil-in-water emulsions, high or low fat. Moist bakery products with surface containing no free fat or oil. Dry solids with the surfaces containing no free fat or oil (no end-test required) and under all conditions as described in Table 2 of FDA Regulation 177.1520 except condition A - high temperature sterilization (e.g. over 100° C / 212° F)

*The term “leakproof” applies to Thermo Scientific Nalgene products that meet the following criteria: a) Bottle/flask/funnel closure systems with closures smaller than 100mm, after they are filled with water, inverted, withstand air pressure of 2psig for 2 minutes, and no water escapes;. b) Bottle/funnel/flask closure systems of larger than 100mm after they are filled with water, inverted for 15 minutes, and no water escapes. Note: these tests, using other liquids, may not yield the same results. To ensure safe usage, customers are advised to test Thermo Scientific Nalgene bottles and closures under conditions of their planned applications. Thermo Scientific Nalgene products are leakproof at ambient temperature and pressure when used with their Nalgene closures.

^Except for oxidizing acids, see "Oxidizing acids, strong."

Narrow-Mouth Round Carboy with Spigot
(2318-series,  8318-series in APAC)
Narrow-Mouth Round Carboy
(2210-series, 8210-series in APAC)
Narrow-Mouth Round Carboy with Tubulation Port
(2302-0050)
Wide-Mouth Round Carboy
(2234-0050)
Classic DI water and lab reagent dispenserClassic DI water and reagent reservoirFor gravity fed liquid dispensing through tubingWide mouth reagent reservoir provides easy access and cleaning
LDPE carboy with white PP closure and PP spigotLDPE carboy with white PP closureLDPE carboy with white PP closureLDPE carboy with white PP closure
RoundRoundRoundRound
Milky white translucentMilky white translucentMilky white translucentMilky white translucent
20L (5.5ga) and 25L (6.5ga)20L (5ga) and 25L (6.5ga)20L (5ga)20L (5ga)
Narrow mouth Narrow mouth Narrow mouth Wide mouth
SpigotNo drainTubing adapter portNo drain
Leakproof*Leakproof*Leakproof*Leakproof*
Temp range
-76°C to 70°C
Temp range
-76°C to 70°C
Temp range
-76°C to 70°C
Temp range
-76°C to 70°C
Not autoclavableNot autoclavableNot autoclavableNot autoclavable
Non-sterileNon-sterileNon-sterileNon-sterile
Graduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallons
Molded-in shoulder handlesMolded-in shoulder handlesMolded-in shoulder handlesMolded-in shoulder handles
Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1Complies with Part 21 CFR 177.1520 for food use1
BPA-freeBPA-freeBPA-freeBPA-free
Phthalate-freePhthalate-freePhthalate-freePhthalate-free

General chemical compatibility

 Narrow-Mouth Round Carboy with Spigot
(2318-series,  8318-series in APAC)
Narrow-Mouth Round Carboy 
(2210-series, 8210-series in APAC)
Narrow-Mouth Round Carboy with Tubulation Port 
(2302-0050)
Wide-Mouth Round Carboy 
(2234-0050)
Acids, dilute or weakEEEE
Acids^ strong, concentratedGGGG
Alcohols, aliphaticEEEE
AldehydesGGGG
Bases/alkaliEEEE
EstersGGGG
Hydrocarbons, aliphaticGGGG
Hydrocarbons, aromaticNNNN
Hydrocarbons, halogenated NNNN
Ketones, aromaticNNNN
Oxidizing agents, strongFFFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.
Narrow-Mouth Round Clearboy with Spigot (2317-0050)Narrow-Mouth Round Clearboy Carboy
(2251-0050)
Wide-Mouth Rectangular Clearboy with Spigot
(2322-0050)
Wide-Mouth Rectangular Clearboy (DS2213-0050)
Dispensing lab media and non-aggressive aqueous lab reagents where a clear view of contents is desired. Compatible with sterilization.Mixing, storing and shipping lab media and non-aggressive aqueous  reagents where a clear view of contents..  Dispensing lab media and non-aggressive aqueous lab reagents where a clear view of contents is desired.  Rectangular shape optimized shelf space.Storing lab media and non-aggressive aqueous lab reagents where a clear view of contents is desired. Rectangular shape optimizes shelf space.
PC with white PP closure/TPE gasket and PP spigotPC with white PP closure/TPE gasket PC with white PP closure and PP spigotPC with white PP closure 
RoundRoundRectangularRectangular
ClearClearClearClear
20L (5ga)20L (5ga)20L (5ga)20L (5ga)
Narrow mouth Narrow mouth Wide mouthWide mouth
SpigotNo drainSpigotNo drain
Leakproof*Leakproof*Leakproof*Leakproof*
Temp range -135°C to 135°CTemp range -135°C to 135°CTemp range -135°C to 135°CTemp range -135°C to 135°C
AutoclavableAutoclavableAutoclavableAutoclavable
Non-sterileNon-sterileNon-sterileNon-sterile
Graduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallonsGraduated in liters and gallons
No handlesNo handlesStainless steel handleStainless steel handle
Complies with Part 21 CFR 177.1580 for food useComplies with Part 21 CFR 177.1580 for food useComplies with Part 21 CFR 177.1580 for food useComplies with Part 21 CFR 177.1580 for food use
Contains BPAContains BPAContains BPAContains BPA
Phthalate-freePhthalate-freePhthalate-freePhthalate-free

General chemical compatibility

 Narrow-Mouth Round Clearboy with Spigot (2317-0050)Narrow-Mouth Round Clearboy Carboy
(2251-0050)
Wide-Mouth Rectangular Clearboy with Spigot
(2322-0050)
Wide-Mouth Rectangular Clearboy (DS2213-0050)
Acids, dilute or weakEEEE
Acids^ strong, concentratedNNNN
Alcohols, aliphaticGGGG
AldehydesFFFF
Bases/alkaliNNNN
EstersNNNN
Hydrocarbons, aliphaticGGGG
Hydrocarbons, aromaticNNNN
Hydrocarbons, halogenated NNNN
Ketones, aromaticNNNN
Oxidizing agents, strongFFFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.

Footnote:

1. HDPE and LDPE are acceptable for: Nonacid, aqueous products; may contain salt, sugar or both (pH above 5.0). Dairy products and modifications; oil-in-water emulsions, high or low fat. Moist bakery products with surface containing no free fat or oil. Dry solids with the surfaces containing no free fat or oil (no end-test required) and under all conditions as described in Table 2 of FDA Regulation 177.1520 except condition A - high temperature sterilization (e.g. over 100° C / 212° F)

*The term “leakproof” applies to Thermo Scientific Nalgene products that meet the following criteria: a) Bottle/flask/funnel closure systems with closures smaller than 100mm, after they are filled with water, inverted, withstand air pressure of 2psig for 2 minutes, and no water escapes;. b) Bottle/funnel/flask closure systems of larger than 100mm after they are filled with water, inverted for 15 minutes, and no water escapes. Note: these tests, using other liquids, may not yield the same results. To ensure safe usage, customers are advised to test Thermo Scientific Nalgene bottles and closures under conditions of their planned applications. Thermo Scientific Nalgene products are leakproof at ambient temperature and pressure when used with their Nalgene closures.

^Except for oxidizing acids, see "Oxidizing acids, strong."

Fluorinated Carboy (2097-0050)Fluorinated Carboy with Spigot
(DS2327-0050)
Storage for solvents and other organic solutions Space-efficient dispensing for non-flammable solvents and other organic solutions 
FLPE with white PP closureFLPE with white PP  closure and fluoropolymer spigot
RoundRectangular 
Milky white translucent, yellowish tint due to fluorination processMilky white translucent, yellowish tint due to fluorination process
20L (5ga)20L (5ga)
Narrow mouthWide mouth
No drainSpigot
Leakproof*Leakproof*
Temp range -100°C to 120°CTemp range -100°C to 120°C
Not autoclavableNot autoclavable
Non-sterileNon-sterile
Graduated in liters and gallonsGraduated in liters and gallons
Molded-in shoulder handleStainless steel handle
Complies with Part 21 CFR 177.1615 for food use1Complies with Part 21 CFR 177.1615 for food use1
BPA-freeBPA-free
Phthalate-freePhthalate-free

General chemical compatibility

 Fluorinated Carboy (2097-0050)Fluorinated Carboy with Spigot 
(DS2327-0050)
Acids, dilute or weakEE
Acids^ strong, concentratedGG
Alcohols, aliphaticEE
AldehydesGG
Bases/alkaliFF
EstersGG
Hydrocarbons, aliphaticEE
Hydrocarbons, aromaticEE
Hydrocarbons, halogenated GG
Ketones, aromaticGG
Oxidizing agents, strongFF

For a more detailed chemical resistance guide by chemical and application temperature, please refer to Chemical resistance guide or request a printed poster for your lab or contact Nalgene Technical Support.

 E No damage after 30 days constant exposure at 20oC. 
 G Little or no damage after 30 days constant exposure at 20oC.
 F Some effect after 7 days constant exposure at 20oC.
 N Not recommended. Immediate damage may occur.

Footnote:

1. HDPE and LDPE are acceptable for: Nonacid, aqueous products; may contain salt, sugar or both (pH above 5.0). Dairy products and modifications; oil-in-water emulsions, high or low fat. Moist bakery products with surface containing no free fat or oil. Dry solids with the surfaces containing no free fat or oil (no end-test required) and under all conditions as described in Table 2 of FDA Regulation 177.1520 except condition A - high temperature sterilization (e.g. over 100° C / 212° F)

*The term “leakproof” applies to Thermo Scientific Nalgene products that meet the following criteria: a) Bottle/flask/funnel closure systems with closures smaller than 100mm, after they are filled with water, inverted, withstand air pressure of 2psig for 2 minutes, and no water escapes;. b) Bottle/funnel/flask closure systems of larger than 100mm after they are filled with water, inverted for 15 minutes, and no water escapes. Note: these tests, using other liquids, may not yield the same results. To ensure safe usage, customers are advised to test Thermo Scientific Nalgene bottles and closures under conditions of their planned applications. Thermo Scientific Nalgene products are leakproof at ambient temperature and pressure when used with their Nalgene closures.

^Except for oxidizing acids, see "Oxidizing acids, strong."

Technical support

For assistance choosing products appropriate for your application, please speak with a Nalgene Technical Support Representative team by phone at +1.585.586.8800 or (1.800.625.4327 US toll free), or email your request to
  technicalsupport@thermofisher.com.

In Austria, France, Germany, Ireland, Switzerland and the United Kingdom please contact technical support by phone at +800 1234 9696 (toll free) or +49.6184.90.6321, or email your request to
  techsupport.labproducts.eu@thermofisher.com.

Regulatory Support: For regulatory documentation of product or material claims, please contact Nalgene Regulatory Support at  RocRegSupport@thermofisher.com


Specialty PP and PPCO Carboys

Additional resources
  • Break the Glass Habit Brochure
  • Bottle and Carboy Selection Guide
  • Plastic Properties Reference Magnet
  • Plastic Labware Chemical Resistance Wall Poster

Request resources