Search Thermo Fisher Scientific
- Contact Us
- Quick Order
-
Don't have an account ? Create Account
Search Thermo Fisher Scientific
For assays that require more flexibility to accommodate all applications, the Thermo Scientific Vanquish Flex UHPLC systems enable you to increase your productivity and drive innovation without compromising quality. Whether you need an LC or LC-MS solution, the flexibility of the Vanquish Flex systems with binary or quaternary solvent blending provides the most advanced performance through better separations, more results and easier interaction.
As a member of the Vanquish UHPLC product line, the Vanquish Flex Binary UHPLC system and Vanquish Flex Quaternary UHPLC system share all Vanquish-inherent values, such as a design focus on uptime, robustness and reliability. The Vanquish Flex systems provide:
Also benefit from the industry-leading, easy-to-use and compliant Thermo Scientific Chromeleon Chromatography Data System (CDS) with eWorkflow method setup, dedicated ePanels, Open Access, and smart tools. Chromeleon CDS delivers advanced system communication with single-point intelligent control and functionality, and provides direct plugins for the Vanquish Flex UHPLC systems to other manufacturers' chromatography data systems.
Reliable and continuous worry-free operation of HPLC instruments is critical for analytical laboratories to achieve the highest productivity and dependable results.
The Thermo Scientific Vanquish Solvent Monitor delivers productivity improvements through the avoidance of unintended dry solvent channels and supports your laboratory's compliance efforts by automatically logging eluent changes. Additionally, monitoring of your waste container levels can ensure your laboratory's smooth operation by preventing hazardous spills.
Solvent and waste levels can be monitored directly on the instrument, through the Thermo Scientific Vanquish User Interface, or remotely with Thermo Scientific Chromeleon Chromatography Data System (CDS) software.
Lab professionals spend a large amount of time interacting with laboratory instruments. The more quickly that operators can understand system status, the more easily they can keep the system delivering results.
With the crisply-designed Thermo Scientific Vanquish User Interface, system health, performance, and equilibration status can be seen at a glance. Additionally, simple maintenance tutorials guide operators to keep the system dependably delivering results. All this can be done remotely or locally, and even when there is no CDS.
Also benefit from the industry-leading, easy-to-use Thermo Scientific Chromeleon CDS software with eWorkflow method setup, dedicated ePanels, and smart tools. Chromeleon CDS delivers advanced system communication with single-point intelligent control and functionality, and provides direct plugins for the Vanquish Horizon UHPLC system to other manufacturers' chromatography data systems.
Find the right solutions for your workflow and achieve better separations. Choose from more than 4,000 products across sample preparation and handling through to columns, including products bundles specifically selected for use with Thermo Scientific Vanquish UHPLC systems.
Vanquish Flex Binary UHPLC System | Vanquish Flex Quaternary UHPLC System | |||
---|---|---|---|---|
Solvent blending | High pressure binary solvent blending for fast and reliable UHPLC | Low pressure quaternary solvent blending for flexible method development | ||
Performance | System pressure | Up to 1000 bar | ||
Retention time precision | ||||
Flow range | 0 – 8 mL/min | |||
Biocompatibility | ||||
System Features | Design | Modular | Modular | |
SmartInject technology for unsurpassed retention time precision | ||||
SmartFlow technology for excellent flow precision | ||||
Pump | High-pressure gradient proportioning | Low-pressure gradient proportioning | ||
Active and passive pre-heating | ||||
Multi-mode column thermostatting | ||||
Sample cooling | Temperature range: 4 – 40 °C | Temperature range: 4 – 40 °C | ||
System components | Pump | Vanquish Binary Pump F UHPLC performance for demanding routine application up to 1000 bar | Vanquish Quaternary Pump F UHPLC performance with more solvent flexibility up to 1000 bar | |
Autosampler | Vanquish Split Sampler FT For applications up to 1000 bar | |||
Extended sample capacity | Vanquish Charger (optional) An intelligent, robotic rack and plate feeder that automatically loads samples in the autosampler and extends the sample capacity of all Vanquish samplers to up to 8832 samples (23 wellplates or 12 vial racks) with innovative air-stream cooling and barcode reading for inventory management. | |||
Column compartment | Vanquish Column Compartment Provides two column thermostatting modes (still and forced air), active and passive solvent pre-conditioning and post-column cooling for optimized control of your separations and advanced method transfer. | |||
Virtually zero dead volume system connections | Viper UHPLC Fittings Kits Order all the UHPLC fittings and capillaries you need for your system or application in a single kit |
= Not applicable | = Poor | = Good | = Better | = Best |
Detector options | Vanquish columns | Chromeleon CDS |
---|---|---|
Extend pressure capabilities and robustness by using columns that were developed for Vanquish systems, allowing you to separate your science better, faster, and easier than ever before.
|
|
HPLC Systems Selection Guide
Use this tool to rank the top HPLC instruments for your applications based on your responses to simple pull-down menus.
HPLC System Total Cost of Ownership Calculator
Use this tool to estimate your cost for purchasing and running Thermo Scientific HPLC and UHPLC systems. You can compare costs between instruments.
LC Method Transfer Calculator
Use this online calculator to transfer methods from HPLC to UHPLC conditions. Calculate the new gradient table, adjust sample volumes and run times if applicable.
Take a virtual tour of the Vanquish and see how each module’s advanced technology will separate your science from the status quo.