Search Thermo Fisher Scientific
- Order Status
- Quick Order
-
Don't have an account ? Create Account
Search Thermo Fisher Scientific
ProLong antifade mountants for fixed cells suppress photobleaching and preserve the signals of your fluorescently labeled target molecules for long-term storage and analysis. ProLong reagents cure within 12–48 hours (depending on sample thickness), forming a semi-rigid gel with a refractive index ranging from 1.47–1.52. Mounted samples can be saved for months with appropriate storage.
ProLong Gold antifade mountant has become a widely used antifade reagent for our Invitrogen high-performance fluorescent dyes and stains because it preserves signal across the entire visible spectrum and causes little or no quenching of the initial signal. ProLong Gold is room-temperature stable—keep it on the bench, ready to use in your next imaging experiment.
ProLong Diamond antifade mountant delivers all the performance of ProLong Gold reagent with Alexa Fluor dyes and provides additional protection for traditional dyes and fluorescent proteins. ProLong Diamond reagent is a superior antifade and mountant, offering low background and photobleaching protection across the visible and near-infrared spectrum. Keep ProLong Diamond reagent refrigerated for the best performance.
ProLong Glass antifade mountant delivers all the performance of ProLong Diamond mountant and offers the best clarity of the ProLong product series—better resolution and improved focal depth for brighter, sharper images. ProLong Glass reagent is a superior antifade reagent with the finest clarity, offering same-as-glass refractive index of 1.52, best focal depth, and low background and photobleaching protection across the visible and near infrared spectrum. Keep ProLong Glass reagent refrigerated for best performance.
FITC photobleach curves obtained from samples illuminated on a widefield or a confocal microscope. HeLa cells were labeled with mouse anti-tubulin primary antibody, detected with fluorescein (FITC)-labeled goat anti-mouse antibody, and mounted with PBS + 50% glycerol or various commercially available antifade mountants. (A) Photobleach curves were collected by illuminating the samples for 2 minutes using a 100‑watt Hg-arc lamp, imaged using a 20x air objective, then acquired using a 12-bit monochrome camera. The data plotted is the mean florescence intensity of three fields of view over time. (B) Photobleach curves were collected using a confocal microscope with a 20x oil-immersion objective scanning regions of interest fifty times with a pixel dwell time of 1.6 microseconds. Excitation source power intensity was set such that ProLong Diamond retained 50% of initial signal intensity at the end of the final scan. Detector gain was held constant for all mounting media. Plotted data is the mean fluorescence intensity from fifteen regions of interest across mounted samples as number of scans.
ProLong Gold Antifade Mountant
| ProLong Diamond Antifade Mountant | ProLong Glass Antifade Mountant | |
---|---|---|---|
Alexa Fluor dyes |
Yes
| Yes |
Yes
|
Traditional dyes and fluorescent proteins |
No
| Yes |
Yes
|
Refractive index (after curing) |
1.47
| 1.47 |
1.52
|
Storage temperature | Room temperature | 2–8°C | 2–8°C |
Ordering information | Ordering information | Ordering information |
ProLong Glass and ProLong Diamond reagents are superior antifades and mountants, offering low background and protection against photobleaching across the visible and near-infrared spectrum in addition to exhibiting less initial quenching of the fluorescent signal. It provides extra protection for traditional dyes such as FITC and fluorescent proteins such as GFP. In a comparison of commercial hard-setting antifade mountants in a standardized experiment, ProLong antifade mountants outperformed other products at preserving signals and preventing photobleaching across the spectrum.
Fluorescent dye |
Ex/Em (nm)
| Resistance to photobleaching* | |||
---|---|---|---|---|---|
ProLong Glass | ProLong Diamond | ProLong Gold | VECTASHIELD | ||
DAPI |
345/455
| +++ | +++ | ++ | ++ |
Hoechst | 350/461 | +++ | +++ | +++ | +++ |
GFP |
488/510
| ++ |
++
|
Not recommended
|
+
|
BODIPY FL |
505/513
| Not tested |
+++
|
+
|
+
|
Fluorescein |
494/518
| +++ |
+++
|
+
|
++
|
Alexa Fluor 488 |
495/519
| +++ |
++
|
++
|
++
|
Alexa Fluor Plus 488 | 495/519 | +++ | ++ | + | + |
Alexa Fluor 555 |
555/565
| +++ |
+++
|
+++
|
+++
|
Alexa Fluor Plus 555 | 555/565 | +++ | +++ | ++ | ++ |
Cy3 |
550/570
| ++ |
++
|
++
|
++
|
Alexa Fluor 546 |
556/575
| ++ | ++ |
+++
|
++
|
Tetramethylrhodamine |
555/580
| ++ |
+++
|
+
|
+
|
TagRFP | 555/584 | Not tested | + | Not recommended | + |
Alexa Fluor 568 |
578/603
| +++ |
+++
|
+
|
+
|
mCherry | 575/610 | +++ | +++ | +++ | +++ |
Texas Red |
595/615
| +++ |
+++
|
+++
|
++
|
Alexa Fluor 594 |
590/617
| +++ |
+++
|
+++
|
++
|
TO-PRO-3 |
642/661
| +++ |
+++
|
+
|
+
|
Alexa Fluor 647 |
652/668
| +++ |
+++
|
+++
|
Not recommended
|
Alexa Fluor Plus 647 | 652/668 | +++ | +++ | +++ | Not recommended |
Cy5 |
650/670
| +++ |
+++
|
+++
|
++
|
Key: +++ = above 80%; ++ = 65—80%, + = 50—65%, Not recommended = below 50%. Percentages express remaining signal intensity. * Photobleaching resistance was quantified by measuring remaining signal intensity on a Zeiss™ LSM 710 confocal microscope. HeLa or U2OS cells were stained and mounted using standard Immunocytochemistry (ICC) protocols. Five regions within three fields of view were scanned 15 times with 1.58 μs dwell time per pixel. Excitation wavelength and intensity were optimized by fluorophore. On an epi-fluorescence microscope using 100-watt Hg-arc lamp, this amount of light/photon exposure will be equal to 60–90 seconds. VECTASHIELD is a trademark of Vector Laboratories, Inc., Burlingame, CA. Hoechst is a trademark of Hoechst, GmbH. Cy is a trademark of GE Healthcare UK, Ltd. |
Offering additional benefits for the ProLong reagent line, ProLong Glass antifade mountant features a refractive index (RI) of approximately 1.52, which is similar to that of cover glass, immersion oil, and oil objective optics. This superior optical clarity means ProLong Glass reagent delivers up to 75% improvement in axial resolution and 3–4 times more imageable focal depth compared to mountants with refractive index of 1.47, producing sharp images for monolayers of cells, tissue slices, or 3D cell cultures up to 150 μm thickness/focal depth.
ProLong Glass, with RI of 1.52, maintains a higher axial resolution than mountants with RI of 1.47. Lateral and axial resolution of 170 μm microspheres in two mountants, plotted as a point spread function (PSF) of images acquired at various focal depths. (Error bars: SD with n ≥ 3).
For Research Use Only. Not for use in diagnostic procedures.