Recirculating Chiller Scientist

A good process makes for good results.
Easy-to-use interfaces and simplified internal engineering means that whatever your task or field of work, you can focus on cooling your application and not your output. For critical applications that require large-batch process cooling, a recirculating chiller offers a versatile, dependable investment, ensuring years of steady, reliable operation.


Thermo Scientific recirculating chillers support a variety of applications, from lab bench to large manufacturing processes. 

Configurable Design

Choose from a wide range of cooling capacities and options to create the right fit for your application. 

Innovative Platform

The result is an easy-to-use, easy-to-maintain, high performance chiller configurable to the most demanding applications. 

Outstanding Performance

Optimized cooling capacity and reliability for your critical application needs.

Choose from a range of recirculating chillers. It's as easy as 1-2-3.

Step 1: Select your chiller by temperature
→ Step 2: Choose the product requirements to complete the system
→ Step 3: Customize your chiller
→ Request a Quote

Step 1: Select your chiller by setpoint temperature range

Click on the range of Watts required to view specifications:

900 to 2500 Watts     |     → 3500 to 10000 Watts     |     → 15000 to 24000 Watts

ThermoFlex→ 900 to 2500 Watts

Model #

TF900

TF1400

TF2500

Cooling Capacity
60Hz900 W / 3074 BTU1400 W / 4781 BTU2500 W / 8538 BTU
50Hz750 W / 2559 BTU1700 W / 3996 BTU2200 W / 7513 BTU
Reservoir Volume1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters
Physical Dimensions27.3 x 14.2 x 24.6 in
(69.2 x 36.0 x 62.4 cm)
27.3 x 14.2 x 24.6 in
(69.2 x 36.0 x 62.4 cm)

29.0 x 17.2 x 26.5 in
(73.6 x 43.6 x 67.3 cm)

Voltage Availability
  • 115V/60Hz, 100V/50Hz
  • 100-115V/50-60Hz
  • 208-230V/60Hz, 200V/50Hz
  • 230V/50Hz
  • 200-230V/50-60Hz
  • 115V/60Hz, 100V/50Hz
  • 100-115V/50-60Hz
  • 208-230V/60Hz, 200V/50Hz
  • 230V/50Hz
  • 200-230V/50-60Hz
  • 208-230V/60Hz, 200V/50Hz
  • 230V/50Hz
  • 200-230V/50-60Hz
ComplianceCE/CSA/UL
Factory RequirementsTF900TF1400TF2500
Pump
Water Cooled
Air Cooled
Heater • 1.0kW @ 208V
• 1.2kW @ 230V
• 2.3kW @ 230V
• 2.8kW @ 208V

• 2.3kW @ 230V
• 2.8kW @ 208V

Factory OptionsTF900TF1400TF2500
 
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only

Flourinert campatible

ThermoFlex→ 3500 to 10000 Watts

Model #

TF3500

TF5000

TF7500

TF10000

Cooling Capacity60Hz3500 W / 11953 BTU5000 W / 17076 BTU7500 W / 25575 BTU10000 W / 34100 BTU
50Hz3050 W / 10416 BTU4400 W / 15027 BTU6425 W / 21910 BTU8500 W / 28985 BTU
Reservoir Volume1.9 gallons / 7.2 liters1.9 gallons / 17.9liters  
Physical
Dimensions
27.3 x 14.2 x 24.6 in
(69.2 x 36.0 x 62.4 cm)
27.3 x 14.2 x 24.6 in
(69.2 x 36.0 x 62.4 cm)
29.0 x 17.2 x 26.5 in
(73.6 x 43.6 x 67.3 cm)
52.3 x 25.2 x 33.8 in
(2.7 x 63.9 x 85.6 cm)
Voltage
Availability
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz/3
• 400V/50Hz/3, 460V/60Hz/3 
 
• 208-230V/60Hz/3
• 400V/50Hz/3, 460V/60Hz/3 
ComplianceCE/CSA/UL
Factory RequirementsTF3500TF5000TF7500TF10000
Pump











Water Cooled
Air Cooled
Heater• 2.3kW @ 230V
• 2.8kW @ 208V
• 2.3kW @ 230V
• 2.8kW @ 208V
• 5.0kW @ 208V
• 6.1kW @ 460V
• 5.0kW @ 208V
• 6.1kW @ 460V
Factory OptionsTF3500TF5000TF7500TF10000
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

ThermoFlex→ 15000 to 24000 Watts

Model #

TF15000

TF20000

TF24000

Cooling Capacity
60 Hz15000 W / 51228 BTU20000 W / 68304 BTU24000 W / 81964 BTU
50 Hz12525 W / 42775 BTU16700 W / 57043 BTU21000 W / 71719 BTU
Reservoir Volume17.9 gallons / 4.8 liters
Physical Dimensions49.0 x 46.5 x 30.9 in
(124.4 x 118.1 x 78.6 cm)
58.6 x 46.5 x 30.9 in
(148.9 x 118.1 x 78.6 cm)
Voltage Availability• 208-230V/60Hz/3
• 400V/50Hz/3Hz, 460V/60Hz/3
ComplianceCE/CSA/UL
Factory Requirements

TF15000

TF20000

TF24000
Pump


Water Cooled
Air Cooled
Heater• 22.5kW @ 460V
Factory OptionsTF15000TF20000TF24000
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

Click on the range of Watts required to view specifications:

1400 to 3500 Watts     |     → 5000 to 10000 Watts     

ThermoFlex → 1400 to 3500 Watts

Model #

TF1400

TF2500

TF3500

Cooling Capacity
60Hz1400 W / 4781 BTU2500 W / 8538 BTU3500 W / 11953 BTU
50Hz1700 W / 3996 BTU2200 W / 7513 BTU3050 W / 10416 BTU
Reservoir Volume1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters
Physical Dimensions27.3x14.2x24.6in
(69.2x36.0x62.4cm)*
29.0x17.2x26.5in
(73.6x43.6x67.3cm)*
38.9x19.3x30.9 in
(98.7x48.8x78.4cm)*
Voltage Availability
• 115V/60Hz, 100V/50Hz
• 100-115V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
ComplianceCE/CSA/UL
Factory RequirementsTF1400TF2500TF3500
Pump






Water Cooled
Air Cooled
Heater• 1.0kW @ 208V
• 1.2kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
Factory OptionsTF1400TF2500TF3500
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

ThermoFlex → 5000 to 10000 Watts

Model #

TF5000

TF7500

TF10000

Cooling Capacity
60Hz5000 W / 17076 BTU7500 W / 25575 BTU10000 W / 34100 BTU
50Hz4400 W / 15027 BTU6425 W / 21910 BTU8500 W / 28985 BTU
Reservoir Volume1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters
Physical Dimensions27.3x14.2x24.6in
(69.2x36.0x62.4cm)*
29.0x17.2x26.5in
(73.6x43.6x67.3cm)*
29.0x17.2x26.5 in
(73.6x43.6x67.3cm)*
Voltage Availability
(v/Hz)
• 115v/60Hz, 100V/50Hz
• 100-115V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
ComplianceCE/CSA/UL
Factory RequirementsTF5000TF7500TF10000
Pump






Water Cooled
Air Cooled
Heater• 1.0kW @ 208V
• 1.2kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
Factory OptionsTF5000TF7500TF10000
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

ThermoFlex

Model #

TF2500

TF5000

TF10000

Cooling Capacity
60 Hz2500 W / 8538 BTU5000 W / 17076 BTU10000 W / 34100 BTU
50 Hz2200 W / 7513 BTU4400 W / 15027 BTU8500 W / 28985 BTU
Reservoir Volume1.9 gallons / 7.2 liters4.75 gallons / 17.9 liters
Physical Dimensions38.9 x 19.3 x 30.9 in
(98.7 x 48.8 x 78.4 cm)
52.3 x 25.2 x 33.8 in
(132.7 x 63.9 x 85.6 cm)
Voltage Availability• 208-230V/60Hz & 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 460V/60Hz, 400V/50Hz
ComplianceCE/CSA/UL
Factory RequirementsTF2500TF5000TF10000
Pump







Water Cooled
Air Cooled
Heater• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 5.0kW @ 208V
• 6.1kW @ 460V
Factory OptionsTF2500TF5000TF10000
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

ThermoChill

Model #

TCI

TCII

TCIII

Temp stability±0.1 °C±0.5 °C
Cooling Capacity
60 Hz700 W / 2391 BTU1000 W / 3415 BTU2000 W / 6830 BTU
50 Hz600 W / 2049 BTU900 W / 3074 BTU1900 W / 6489 BTU
Reservoir Volume9.5 liters (2.5 gallons)19.0 liters (5.0 gallons)
Physical Dimensions24.4 x 14.2 x 23.6 in
(62 x 36.1 x 59.9 cm)
28.6 x 17.3 x 23.6 in
(72.6 x 43.9 x 59.9 cm)
Voltage Availability115V/60Hz
100V/50Hz
230V/50Hz
208-230V /60Hz
200V/50Hz
230V/50Hz
ComplianceCE/UL  
Factory RequirementsTCITCIITCIII
60 Hz1.4 gpm @ 60 psid (5.3 lpm @ 4.1 bar)
50 Hz1.2 gpm @ 60 psid (4.5 lpm @ 4.1 bar)

60 Hz3.6 gpm @ 60 psid (13.6 lpm @ 4.1 bar)
50 Hz2.5 gpm @ 60 psid (9.4 lpm @ 4.1 bar)
Air Cooled
Factory OptionsTC1TCIITCIII
RS232 only

Polar

Model #

250 LC

500 LC

Cooling Capacity at 20°C
250 W / 853 BTU500 W / 1706 BTU
Reservoir Volume2.8 liters (0.74 gallons)
Physical Dimensions24.8 x 9.1 x 19.2 in
(62.0 x 23.2 x 48.7 cm)
Voltage Availability115V/60Hz
100V/50-60Hz
220-230V/50Hz
220V/60Hz
ComplianceCE/RoHS/UL
Factory Requirements250 LC500 LC
Force Pump 
- Maxmimum Flow
- Maximum Pressue

- 15 lpm (3.96 gpm)
- 805 mbar (11.7 psi)
Force / Suction Pump 
- Maxmimum Flow
- Maximum Pressue

- 21 lpm (5.5 gpm)
- 805 mbar (11.7 psi)
There are no factory options for Polar

Merlin

Model #

M75

M150

Cooling Capacity
60 Hz2156 W / 7356 BTU4832 W / 16487 BTU
50 Hz2156 W / 7356 BTU4282 W / 14610 BTU
Reservoir Volume0.5 gallons / 1.8 liters
Physical Dimensions26.1 x 16.3 x 24 in
(66.4 x 41.3 x 61.0 cm)
30.4 x 21.3 x 29.3 in
(77.2 x 54.0 x 74.3 cm)
Voltage Availability230V/50Hz
200-230V/60Hz
• 230V/50Hz
• 208-230V/60Hz
• 400V/50Hz
ComplianceUL
Factory RequirementsM75M150
Pump



Air Cooled
Factory OptionsM75M150
RS232 only
Fluorinert Compatible-

Polar

Model #

500 LT

500 LT/HT

Cooling Capacity at 20°C 
500W / 1706 BTU
Reservoir Volume0.74 gallons / 2.8 liters
Physical Dimensions24.8 x 9.1 x 19.2 in
(62.0 x 23.2 x 48.7 cm)
Voltage?115V/60Hz
100V/50-60Hz
220-230V/50Hz
220V/60Hz
115V/60Hz
220-230V/50Hz
ComplianceCE/RoHS/UL
Factory Requirements

500 LT

500 LT/HT

Force / Suction Pump 
- Maxmimum Flow
- Maximum Pressue

- 21 lpm (5.5 gpm)
- 805 mbar (11.6 psi)
There are no factory options for Polar

Click on the range of Watts required to view specifications:

900 to 2500 Watts     |     → 3500 to 10000 Watts     |     → 15000 to 24000 Watts

ThermoFlex→ 900 to 2500 Watts

Model #

TF900

TF1400

TF2500

Cooling Capacity
60Hz900 W / 3074 BTU1400 W / 4781 BTU2500 W / 8538 BTU
50Hz750 W / 2559 BTU1700 W / 3996 BTU2200 W / 7513 BTU
Reservoir Volume1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters
Physical Dimensions27.3 x 14.2 x 24.6 in
(69.2 x 36.0 x 62.4 cm)
27.3 x 14.2 x 24.6 in
(69.2 x 36.0 x 62.4 cm)

29.0 x 17.2 x 26.5 in
(73.6 x 43.6 x 67.3 cm)

Voltage Availability
  • 115V/60Hz, 100V/50Hz
  • 100-115V/50-60Hz
  • 208-230V/60Hz, 200V/50Hz
  • 230V/50Hz
  • 200-230V/50-60Hz
  • 115V/60Hz, 100V/50Hz
  • 100-115V/50-60Hz
  • 208-230V/60Hz, 200V/50Hz
  • 230V/50Hz
  • 200-230V/50-60Hz
  • 208-230V/60Hz, 200V/50Hz
  • 230V/50Hz
  • 200-230V/50-60Hz
ComplianceCE/CSA/UL
Factory RequirementsTF900TF1400TF2500
Pump
Water Cooled
Air Cooled
Heater • 1.0kW @ 208V
• 1.2kW @ 230V
• 2.3kW @ 230V
• 2.8kW @ 208V

• 2.3kW @ 230V
• 2.8kW @ 208V

Factory OptionsTF900TF1400TF2500
 
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only

Flourinert campatible

ThermoFlex→ 3500 to 10000 Watts

Model #

TF3500

TF5000

TF7500

TF10000

Cooling Capacity60Hz3500 W / 11953 BTU5000 W / 17076 BTU7500 W / 25575 BTU10000 W / 34100 BTU
50Hz3050 W / 10416 BTU4400 W / 15027 BTU6425 W / 21910 BTU8500 W / 28985 BTU
Reservoir Volume1.9 gallons / 7.2 liters1.9 gallons / 17.9liters  
Physical
Dimensions
27.3 x 14.2 x 24.6 in
(69.2 x 36.0 x 62.4 cm)
27.3 x 14.2 x 24.6 in
(69.2 x 36.0 x 62.4 cm)
29.0 x 17.2 x 26.5 in
(73.6 x 43.6 x 67.3 cm)
52.3 x 25.2 x 33.8 in
(2.7 x 63.9 x 85.6 cm)
Voltage
Availability
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz/3
• 400V/50Hz/3, 460V/60Hz/3 
 
• 208-230V/60Hz/3
• 400V/50Hz/3, 460V/60Hz/3 
ComplianceCE/CSA/UL
Factory RequirementsTF3500TF5000TF7500TF10000
Pump











Water Cooled
Air Cooled
Heater• 2.3kW @ 230V
• 2.8kW @ 208V
• 2.3kW @ 230V
• 2.8kW @ 208V
• 5.0kW @ 208V
• 6.1kW @ 460V
• 5.0kW @ 208V
• 6.1kW @ 460V
Factory OptionsTF3500TF5000TF7500TF10000
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

ThermoFlex→ 15000 to 24000 Watts

Model #

TF15000

TF20000

TF24000

Cooling Capacity
60 Hz15000 W / 51228 BTU20000 W / 68304 BTU24000 W / 81964 BTU
50 Hz12525 W / 42775 BTU16700 W / 57043 BTU21000 W / 71719 BTU
Reservoir Volume17.9 gallons / 4.8 liters
Physical Dimensions49.0 x 46.5 x 30.9 in
(124.4 x 118.1 x 78.6 cm)
58.6 x 46.5 x 30.9 in
(148.9 x 118.1 x 78.6 cm)
Voltage Availability• 208-230V/60Hz/3
• 400V/50Hz/3Hz, 460V/60Hz/3
ComplianceCE/CSA/UL
Factory Requirements

TF15000

TF20000

TF24000
Pump


Water Cooled
Air Cooled
Heater• 22.5kW @ 460V
Factory OptionsTF15000TF20000TF24000
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

Click on the range of Watts required to view specifications:

1400 to 3500 Watts     |     → 5000 to 10000 Watts     

ThermoFlex → 1400 to 3500 Watts

Model #

TF1400

TF2500

TF3500

Cooling Capacity
60Hz1400 W / 4781 BTU2500 W / 8538 BTU3500 W / 11953 BTU
50Hz1700 W / 3996 BTU2200 W / 7513 BTU3050 W / 10416 BTU
Reservoir Volume1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters
Physical Dimensions27.3x14.2x24.6in
(69.2x36.0x62.4cm)*
29.0x17.2x26.5in
(73.6x43.6x67.3cm)*
38.9x19.3x30.9 in
(98.7x48.8x78.4cm)*
Voltage Availability
• 115V/60Hz, 100V/50Hz
• 100-115V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
ComplianceCE/CSA/UL
Factory RequirementsTF1400TF2500TF3500
Pump






Water Cooled
Air Cooled
Heater• 1.0kW @ 208V
• 1.2kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
Factory OptionsTF1400TF2500TF3500
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

ThermoFlex → 5000 to 10000 Watts

Model #

TF5000

TF7500

TF10000

Cooling Capacity
60Hz5000 W / 17076 BTU7500 W / 25575 BTU10000 W / 34100 BTU
50Hz4400 W / 15027 BTU6425 W / 21910 BTU8500 W / 28985 BTU
Reservoir Volume1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters1.9 gallons / 7.2 liters
Physical Dimensions27.3x14.2x24.6in
(69.2x36.0x62.4cm)*
29.0x17.2x26.5in
(73.6x43.6x67.3cm)*
29.0x17.2x26.5 in
(73.6x43.6x67.3cm)*
Voltage Availability
(v/Hz)
• 115v/60Hz, 100V/50Hz
• 100-115V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
ComplianceCE/CSA/UL
Factory RequirementsTF5000TF7500TF10000
Pump






Water Cooled
Air Cooled
Heater• 1.0kW @ 208V
• 1.2kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
Factory OptionsTF5000TF7500TF10000
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

ThermoFlex

Model #

TF2500

TF5000

TF10000

Cooling Capacity
60 Hz2500 W / 8538 BTU5000 W / 17076 BTU10000 W / 34100 BTU
50 Hz2200 W / 7513 BTU4400 W / 15027 BTU8500 W / 28985 BTU
Reservoir Volume1.9 gallons / 7.2 liters4.75 gallons / 17.9 liters
Physical Dimensions38.9 x 19.3 x 30.9 in
(98.7 x 48.8 x 78.4 cm)
52.3 x 25.2 x 33.8 in
(132.7 x 63.9 x 85.6 cm)
Voltage Availability• 208-230V/60Hz & 200V/50Hz
• 230V/50Hz
• 200-230V/50-60Hz
• 208-230V/60Hz, 200V/50Hz
• 460V/60Hz, 400V/50Hz
ComplianceCE/CSA/UL
Factory RequirementsTF2500TF5000TF10000
Pump







Water Cooled
Air Cooled
Heater• 2.3kW @ 208V
• 2.8kW @ 230V
• 2.3kW @ 208V
• 2.8kW @ 230V
• 5.0kW @ 208V
• 6.1kW @ 460V
Factory OptionsTF2500TF5000TF10000
Internal Pressure Relief
External Pressure Relief
Anti-Drainback

Analog Comm
RS232 only
Flourinert campatible

ThermoChill

Model #

TCI

TCII

TCIII

Temp stability±0.1 °C±0.5 °C
Cooling Capacity
60 Hz700 W / 2391 BTU1000 W / 3415 BTU2000 W / 6830 BTU
50 Hz600 W / 2049 BTU900 W / 3074 BTU1900 W / 6489 BTU
Reservoir Volume9.5 liters (2.5 gallons)19.0 liters (5.0 gallons)
Physical Dimensions24.4 x 14.2 x 23.6 in
(62 x 36.1 x 59.9 cm)
28.6 x 17.3 x 23.6 in
(72.6 x 43.9 x 59.9 cm)
Voltage Availability115V/60Hz
100V/50Hz
230V/50Hz
208-230V /60Hz
200V/50Hz
230V/50Hz
ComplianceCE/UL  
Factory RequirementsTCITCIITCIII
60 Hz1.4 gpm @ 60 psid (5.3 lpm @ 4.1 bar)
50 Hz1.2 gpm @ 60 psid (4.5 lpm @ 4.1 bar)

60 Hz3.6 gpm @ 60 psid (13.6 lpm @ 4.1 bar)
50 Hz2.5 gpm @ 60 psid (9.4 lpm @ 4.1 bar)
Air Cooled
Factory OptionsTC1TCIITCIII
RS232 only

Polar

Model #

250 LC

500 LC

Cooling Capacity at 20°C
250 W / 853 BTU500 W / 1706 BTU
Reservoir Volume2.8 liters (0.74 gallons)
Physical Dimensions24.8 x 9.1 x 19.2 in
(62.0 x 23.2 x 48.7 cm)
Voltage Availability115V/60Hz
100V/50-60Hz
220-230V/50Hz
220V/60Hz
ComplianceCE/RoHS/UL
Factory Requirements250 LC500 LC
Force Pump 
- Maxmimum Flow
- Maximum Pressue

- 15 lpm (3.96 gpm)
- 805 mbar (11.7 psi)
Force / Suction Pump 
- Maxmimum Flow
- Maximum Pressue

- 21 lpm (5.5 gpm)
- 805 mbar (11.7 psi)
There are no factory options for Polar

Merlin

Model #

M75

M150

Cooling Capacity
60 Hz2156 W / 7356 BTU4832 W / 16487 BTU
50 Hz2156 W / 7356 BTU4282 W / 14610 BTU
Reservoir Volume0.5 gallons / 1.8 liters
Physical Dimensions26.1 x 16.3 x 24 in
(66.4 x 41.3 x 61.0 cm)
30.4 x 21.3 x 29.3 in
(77.2 x 54.0 x 74.3 cm)
Voltage Availability230V/50Hz
200-230V/60Hz
• 230V/50Hz
• 208-230V/60Hz
• 400V/50Hz
ComplianceUL
Factory RequirementsM75M150
Pump



Air Cooled
Factory OptionsM75M150
RS232 only
Fluorinert Compatible-

Polar

Model #

500 LT

500 LT/HT

Cooling Capacity at 20°C 
500W / 1706 BTU
Reservoir Volume0.74 gallons / 2.8 liters
Physical Dimensions24.8 x 9.1 x 19.2 in
(62.0 x 23.2 x 48.7 cm)
Voltage?115V/60Hz
100V/50-60Hz
220-230V/50Hz
220V/60Hz
115V/60Hz
220-230V/50Hz
ComplianceCE/RoHS/UL
Factory Requirements

500 LT

500 LT/HT

Force / Suction Pump 
- Maxmimum Flow
- Maximum Pressue

- 21 lpm (5.5 gpm)
- 805 mbar (11.6 psi)
There are no factory options for Polar

Explore which chiller is right for your application. Find your recirculating chiller


Used in the following applications

  • Analytical
  • Automotive
  • Biotech
  • Laboratory
  • Laser
  • Medical
  • Metrology
  • Packaging
  • Pharmaceutical
  • Printing
  • Research
  • Semiconductor
  • Industrial
  • University

Accessories for your chillers


Essential Plasticware, Components and Equipment for OEM

oem

Our breadth of laboratory plasticware and equipment products help expand and compliment the portfolios of our partners in life science research, diagnostic manufacturing and industrial markets. Our wide range of options include off-the-shelf and customized solutions to meet your specific needs.

Learn more


Related temperature controlled areas

Temperature Control Resources

chillers-family

Visit our resource library to learn more about our advanced products and services for precision temperature control.

Learn more

Determine the amount of heat a recirculating chiller adds to a room