Search Thermo Fisher Scientific
Rely on Orion ion selective electrodes for superior performance and reproducible results. Obtain accuracy by leveraging NIST-traceable calibration standards along with ionic strength adjusters, reagents, and fill solutions for all ISE measurement needs.
Ion Selective Electrodes: | View all |
Combination Fl ISE with reference | High performance ammonia electrode | Combination Cl ISE with Sure-Flow reference | Combination Na ISE with Sure-Flow reference | |
Combination fluoride ISE with Sure-Flow reference | Body and membrane assembly simplifies use; delivering optimum performance | Combination chloride ISE with Sure-Flow reference | Combination Ross Sodium ISE with Sure-Flow reference | |
|
|
|
| |
Product SKU number | 9609BNWP1 | 9512HPBNWP1 | 9617BNWP1 | 8611BNWP1 |
Measurement Range | 1 x 10-6 M to saturated 0.02 ppm to saturated | 5 x 10-7 to 1.0 M 0.01 to 17,000 ppm | 5 x 10-5 to 1.0 M 1.8 to 35,000 ppm | 1 x 10-6 M to saturated 0.02 ppm to saturated |
Temp. Range | 0° - 80°C | 0° - 50°C | 0° - 80°C | 0° - 100°C |
Connector Type | BNC Waterproof | BNC Waterproof | BNC Waterproof | BNC Waterproof |
Increase your productivity with
ISE electrode accessories See our complete list of
ISE electrodes |
Our solutions are known for delivering accurate and reproducible ISE measurement results. We test our Orion ISE solutions using the measurement equipment and ISE it is made for. Ensure the integrity of your ISE measurements by pairing your high quality electrodes with our high quality solutions.
Product SKU | Description |
Ammonia for 9512BNWP Standard and 9512HPBNWP High Performance Electrodes | |
951006 | 0.1 M NH4Cl Ammonia standard, 475mL |
951007 | 1000 ppm Ammonia as Nitrogen (N) standard, 475mL |
951207 | 100 ppm Ammonia as Nitrogen (N) standard, 475mL |
951211 | Ammonia Ionic Strength Adjuster (ISA) with pH-indicating blue dye, 475mL, for samples containing metallic ions |
951210 | Ammonia low level Ionic Strength Adjuster (ISA) with pH-indicating blue dye, 475mL, for samples with no metallic ions |
951213 | Ammonia electrode storage solution, 475mL |
951209 | Ammonia high perform electrode fill solution, 60mL |
951202 | Ammonia standard electrode fill solution, 60mL |
Ammonium Solutions for 931801 Module, 9300BNWP Handle & 900200 Reference Electrode | |
951007 | 1000 ppm Ammonium as Nitrogen (N) standard, 475mL |
900018-WA | Ammonium electrode fill solution, 5 x 60mL |
Bromide Solutions for 9635BNWP Combination or 9435BN & 900200 Half-cell Electrodes | |
943506 | 0.1M NaBr Bromide standard, 475mL |
940011 | Bromide Ionic Strength Adjuster (ISA), 475mL |
900063 | Optimum results D fill solution, 5 x 60mL |
Cadmium: Solutions for 9648BNWP Combination or 9448BN & 900200 Half-cell Electrode | |
940011 | Cadmium Ionic Strength Adjuster (ISA), 475mL |
900061 | Optimum results A fill solution, 5 x 60mL |
Calcium: Solutions for 9720BNWP Combination or 9320BN & 900100 Half-cell Electrodes | |
922006 | 0.1 M CaCl2 Calcium standard, 475mL |
923206 | 100 ppm as CaCO3 Calcium standard, 475mL |
932011 | Calcium Ionic Strength Adjuster (ISA), 475mL |
900061 | Optimum results A fill solution, 5 x 60mL |
Carbon Dioxide: Solutions for 9502BNWP Electrode | |
950206 | 0.1 M NaHCO3 Carbon Dioxide standard, 475mL |
950207 | 1000 ppm as CaCO3 Carbon Dioxide standard, 475mL |
950210 | Carbon Dioxide Ionic Strength Adjuster (ISA), 475mL |
950202 | Carbon Dioxide electrode fill solution, 60mL |
Chloride: Solutions for 9617BNWP Combination or 9417BN & 900200 Half-cell Electrodes | |
941706 | 0.1 M NaCl Chloride standard, 475mL |
941708 | 1000 ppm Chloride standard, 475mL |
941707 | 100 ppm Chloride standard, 475mL |
940011 | Chloride Ionic Strength Adjuster (ISA), 475mL |
941709 | Chloride Complexation Ionic Strength Adjuster (CISA) reagent pack, 2 x 1L |
900062 | Optimum results B fill solution, 5 x 60mL |
900017 | Chloride electrode fill solution, 5 x 60mL |
Chlorine, Residual: Solutions for 9770BNWP Electrode | |
977007 | 100 ppm as Cl2 Residual Chlorine standard, 475mL |
977011 | Residual Chlorine acid reagent, 475mL |
977010 | Residual Chlorine iodide reagent, 5 x 50mL |
Cupric: Solutions for 9629BNWP Combination or 9429BN & 900200 Half-cell Electrodes | |
942906 | 0.1 M Cu(NO3)2 Cupric standard, 475mL |
940011 | Cupric Ionic Strength Adjuster (ISA), 475mL |
900063 | Optimum results D fill solution, 5 x 60mL |
Cyanide: Solutions for 9606BNWP Combination or 9406BN & 900200 Half-cell Electrodes | |
951011 | Cyanide alkaline reagent, 10 N NaOH, 475mL |
900062 | Optimum results B fill solution, 5 x 60mL |
Fluoride: Solutions for 9609BNWP Combination or 9409BN & 900100 Half-cell Electrodes | |
940906 | 0.1 M NaF Fluoride standard, 475mL |
940907 | 100 ppm Fluoride standard, 475mL |
040908 | 10 ppm Fluoride standard premixed with TISAB II, color coded blue, 475mL |
040907 | 2 ppm Fluoride standard premixed with TISAB II, color coded red, 475mL |
040906 | 1 ppm Fluoride standard premixed with TISAB II, color coded green, 475mL |
940916 | Fluoride Standard Bulk Pack – 4 x 475mL each of 1 ppm Fluoride standard premixed with TISAB II (040906) and 10 ppm Fluoride standard premixed with TISAB II (040908) |
940909 | TISAB II for Fluoride ISE, 1 gallon |
940999 | TISAB II for Fluoride ISE, 4 x 1 gallon |
940911 | TISAB III (concentrated) for Fluoride ISE, 475mL |
900061 | Optimum results A fill solution, 5 x 60mL |
Fluoroborate: Solutions for 9305BN & 900200 Half-cell Electrodes | |
930711 | Fluoroborate Ionic Strength Adjuster (ISA), 475mL |
Iodide: Solutions for 9653BNWP Combination or 9453BN & 900200 Half-cell Electrodes | |
945306 | 0.1 M NaI Iodide standard, 475mL |
940011 | Iodide Ionic Strength Adjuster (ISA), 475mL |
900063 | Optimum results D fill solution, 5 x 60mL |
Lead: Solutions for 9682BNWP Combination or 9482BN & 900200 Half-cell Electrodes | |
948206 | 0.1 M Pb(ClO4)2 Lead standard, 475mL |
900062 | Optimum results B fill solution, 5 x 60mL |
Nitrate Solutions | |
920706 | 0.1 M NaNO3 Nitrate standard, 475mL |
920707 | 1000 ppm Nitrate as Nitrogen (N) standard, 475mL |
930707 | 100 ppm Nitrate as Nitrogen (N) standard, 475mL |
930711 | Nitrate Ionic Strength Adjuster (ISA), 475mL |
930710 | Nitrate Interference Suppressor Solution (NISS), 475mL |
900046 | Optimum results F fill solution, 5 x 60mL |
Nitrogen Oxide Solutions | |
956410 | Nitrogen Oxide acid buffer, 475mL |
954602 | Nitrogen Oxide electrode fill solution, 50mL |
Perchlorate Solutions | |
930711 | Perchlorate Ionic Strength Adjuster (ISA), 475mL |
Potassium: Solutions for 9719BNWP Combination or 9319BN & 900200 Half-cell Electrodes | |
921906 | 0.1M KCl Potassium standard, 475mL |
931911 | Potassium Ionic Strength Adjuster (ISA), 475mL |
900065 | Optimum results E fill solution, 5 x 60mL |
Silver: Solutions for 9616BNWP Combination or 9416BN & 900200 Half-cell Electrodes | |
940011 | Silver Ionic Strength Adjuster (ISA), 475mL |
900062 | Optimum results B fill solution, 5 x 60mL |
900067 | Optimum results C fill solution (when sample temperatures vary), 5 x 60mL |
Sodium: Solutions for 8611BNWP Combination or 8411BN & 800300 Half-cell Electrodes | |
941706 | 0.1M NaCl Sodium standard, 475mL |
841108 | 1000 ppm Sodium standard, 475mL |
941107 | 100 ppm Sodium standard, 475mL |
941105 | 10 ppm Sodium standard, 475mL |
841111 | Sodium Ionic Strength Adjuster (ISA), 475mL |
841113 | Sodium electrode reconditioning solution, 475mL |
841101 | Sodium electrode storage solution, 475mL |
650700 | Sodium KAP Analysis Kit – 3 x 475mL of 1 M NaCl with ISA and 47mL of Sodium ISA (841111) |
841109 | Sodium KAP standard, 1000 ppm with ISA, 475mL |
900010 | Sodium electrode fill solution, 5 x 60mL |
900012 | Sodium electrode (low level) fill solution, 5 x 60mL |
900004 | Sodium micro electrode fill solution, 5 x 60mL |
Sulfate: Solution for 9682BNWP Lead Electrode | |
948207 | 0.1M Na2SO4 sulfate standard for lead electrode, 475mL |
Sulfide Solutions for 9616BNWP Combination or 9416BN and 900200 Half-cell Electrodes: Solutions for 9616BNWP Combination or 9416BN & 900200 Half-cell Electrodes | |
941609 | Sulfide SAOB reagent pack, 4 x 475mL |
900061 | Optimum results A fill solution for Sulfide electrode (when sample temperatures vary), 5 x 60mL |
900062 | Optimum results B fill solution for Silver/Sulfide electrode, 5 x 60mL |
Surfactant Solutions for 9342BN & 900200 Half-cell Electrodes: Solutions for 9342BN & 900200 Half-cell Electrodes | |
654202 | 0.01M SLS Surfactant standard, 1 x 60mL |
654201 | 0.05M hyamine Surfactant titrant, 475mL |
654203 | Surfactant sample additive, tritonX-100, 475 mL |
810007 | Surfactant electrode fill solution, 5 x 60 mL |
Thiocyanate: Solutions for 9458BN & 900200 Half-cell Electrodes | |
940011 | Thiocyanate Ionic Strength Adjuster (ISA), 475mL |
Water Hardness Solutions | |
922006 | 0.1M CaCl2 Water Hardness standard, 475mL |
923206 | 100 ppm as CaCO3 Water Hardness standard, 475mL |
Signifies a hazardous solution. | ^ Top |
Explore a full line of supporting accessories offered to meet your ISE measurement needs. Replacement modules are available individually or in convenient three-packs.
Product SKU | Description |
948201 | Polishing strips for solid state electrodes |
Ammonia, High Performance (9512HPBNWP, 9512HP01) | |
951214 | 20 loose membranes |
951215 | 3 pre-assembled bodies and membrane caps |
Ammonia, Standard (9512BNWP, 951201) | |
951204 | 20 loose membranes |
951205 | 3 bonded membranes |
Carbon Dioxide (9502BNWP) | |
950204 | 4 membranes with o-rings |
Nitrogen Oxide (9546BN) | |
954604 | 20 loose membranes |
97 Series Plastic Membrane Calcium, Nitrate and Potassium Combination Electrode Accessories | |
972001 | Replacement module for calcium combination electrode (9720BNWP) |
970701 | Replacement module for nitrate combination electrode (9707BNWP) |
s971901 | Replacement module for potassium combination electrode (9719BNWP) |
93 Series Plastic Membrane Ammonium, Calcium, Chloride, Fluoroborate, HF Resistant pH, Nitrate, Perchlorate, Potassium and Water Hardness Half-Cell Electrode Accessories | |
9300BNWP | 93 series electrode body with waterproof BNC connection |
900100 | Single junction reference electrode with pin tip connection |
900200 | Double junction reference electrode with pin tip connection |
931801 | Replacement module for ammonium half-cell electrode |
932001 | Replacement module for calcium half-cell electrode (9320BN) |
930501 | Replacement module for fluoroborate half-cell electrode (9305BN) |
930702 | Replacement module for nitrate half-cell electrode (9307BNWP) |
930701 | Replacement modules (3) for nitrate half-cell electrode (9307BNWP) |
931901 | Replacement module for potassium half-cell electrode (9319BN) |
The accuracy and reliability of your measurements depends on the instrumentation you use. Learn more about how you can identify the best match based on your required features, performance, specifications, and budget. |
Perform quick and accurate measurements by using high quality Thermo Scientific Orion Ion Specific Electrodes and reagents for ion specific measurement. We offer a comprehensive portfolio of ion selective electrode calibration standards, ionic strength adjusters, reagents, and fill solutions for your ISE measurement needs. All the consumables you need to measure fluoride or ammonia in water and wastewater are available with one part number.
We make ammonia measurements easy by offering a complete line of ammonia standards, reagents, storage solution and fill solutions for your ion selective electrode. Combined with an Orion ammonia electrode, our solutions provide highly accurate measurements, low limits of detection and easy maintenance
Knowledge Base: Certificates of Analysis and SDS for Orion, ROSS, AQUAfast, AquaMate, and AquaSensors products.
Orion Meters Software and Upgrades
Thermo Scientific Orion benchtop and portable meters are designed to help deliver accurate, consistent results, day after day. Boost productivity by upgrading your software today.