Search Thermo Fisher Scientific
Thermo Scientific Pierce Active GTPase Pull-down and Detection Kits profile the activation of small GTPases by isolating them via their specific downstream effectors.
Active (GTP-bound) small GTPases are difficult to directly detect because no primary antibodies are available that are specific for the active forms. To circumvent this problem, the Pierce Kits precede detection with pull-down purification to differentiate active GTPases from their inactive, GDP-bound conformation based on their affinity for downstream effector proteins.
This affinity provides a method to distinguish the transient up- or down-regulation of the active populations of GTPases from global changes in GTPase expression. These transient changes in activation could be the experimental result of exposing cells to growth factors or other small-molecule stimulators or inhibitors, or due to changes that occur during cell growth, differentiation, tumorigenesis, and metastasis.
Active GTPases interact with specific downstream effector proteins. These specific protein-protein interactions can be exploited to capture active GTPases by using the effector proteins as the bait in pull-down assays. The GTPase protein-binding domains (PBDs) of these effector proteins are expressed as functional GST-fusion proteins that can be immobilized to glutathione agarose, facilitating the capture and enrichment of the active forms of their cognate GTPases. Although effector proteins often interact with one or more active GTPase, each GTPase can be individually identified and the relative quantity determined by western blot analysis after the pull-down assay.
The GTPase pull-down assay procedure is streamlined with the Thermo Scientific Pierce Active GTPase Pull-Down and Detection Kits, which are available for Arf1, Cdc42, Rac1, Rap1, Ras and Rho small GTPases. The pull-down affinity purification step is easily performed in convenient spin columns. After washing, the bound GTPase is recovered by eluting the GST-fusion protein from the glutathione resin. The purified GTPase is detected by Western blot using a specific antibody supplied in each kit. Relative differences in active GTPase signal can be quantified by densitometry or CCD camera. The GTPase pull-down procedure is already optimized for western blot analysis using Thermo Scientific SuperSignal West Pico Chemiluminescent Substrate and HRP-conjugated secondary antibodies (available separately).
Performing pull-down assays with the Active GTPase Pull-Down and Detection Kits is straightforward. First, whole cell lysates are prepared from cultured cells using the lysis buffer provided in the kit. Lysate (containing active and inactive GTPase) is incubated with the GST-protein binding domain (PBD) fusion protein from the respective downstream effector protein and glutathione resin. This specific interaction enables isolation of the target active (GTP-bound) GTPase. Unbound lysate proteins, including inactive or GDP-bound GTPase, are removed using the spin columns. The active GTPase population is recovered from the glutathione resin using SDS-PAGE loading buffer and analyzed by western blot.
Cat. No. | GTPase | Downstream effector binding domain-GST fusion | Key cellular functions |
---|---|---|---|
16121 | Arf1 | GST-GGA3-PBD | Assembly of coat proteins onto budding vesicles on trans-golgi network and endosomes |
16119 | Cdc42 | GST-Pak1-PBD | Filopodia, lamellipodia formation, and stress fibers |
16118 | Rac1 | GST-Pak1-PBD | Filopodia, lamellipodia formation, and stress fibers |
16120 | Rap1 | GST-RalGDS-RBD | Cell proliferation/differentiation |
16117 | Ras | GST-Raf1-RBD | Cell proliferation/differentiation; motility |
16116 | Rho | GST-Rhotekin-RBD | Filopodia, lamellipodia formation, and stress fibers; motility |
Each Active GTPase Pull-down and Detection Kit contains sufficient material to perform 30 pull-down assays from a 0.5 to 1 mg cell lysate sample and the following components: GST-fusion protein with the GTPase-specific binding domain, glutathione agarose resin, GTPγS (positive control), GDP (negative control), lysis/binding/wash buffer, GTPase-specific primary antibody, SDS-PAGE sample loading buffer, spin columns and collection tubes. |
The effectiveness of the Active GTPase Pull-Down and Detection Kits is from a combination of the integrity of the GST-effector binding domain and the quality of the primary antibody provided in the kit. In a comparison of commercial assays available to detect active Ras, each product detects a similar activation pattern, but the Active GTPase Pull-down and Detection Kit is more sensitive than pull-down and ELISA kits from other suppliers.
For Research Use Only. Not for use in diagnostic procedures.