Search Thermo Fisher Scientific
- Order Status
- Quick Order
-
Don't have an account ? Create Account
Search Thermo Fisher Scientific
Targeted quantitation is performed in proteomic experiments to increase the sensitivity of detection for a limited number of target analytes. These approaches require spiking a sample with known amounts of synthetic peptides containing heavy stable isotopes, which act as internal quantitative standards for quantitation of the corresponding natural peptides in the sample. The main types of targeted quantitation methods include single reaction monitoring (SRM) and parallel reaction monitoring (PRM). SureQuant PRM is the next generation of assays that include a suite of kits and standards to enable multiplexed quantitation of key cellular targets.
The Thermo Scientific SureQuant Assays have been designed for multiplexed targeted quantitation for key cellular signaling proteins and include reagents for multiplexed immunoprecipitation and MS sample preparation, heavy peptide quantitation panels, and suitability standards to assess system performance. Together, the SureQuant assay system provides flexibility to use the immunoprecipitation sample prep kits and peptide quantitation modules together, or independently, based on the end-application for robust quantitation.
The AKT pathway IP-MS sample preparation kit is used to immuno-enrich total target proteins of AKT-mTOR pathway with subsequent in-solution MS sample preparation. The quantitation module enables relative quantitation of unique peptides of AKT pathway proteins using LC-MS.
Learn more about AKT pathway (total) reagents
Workflow step | Product | Target proteins | Unit size | Cat. No. |
---|---|---|---|---|
Sample prep | SureQuant AKT Pathway IP and MS Sample Preparation Module | AKT/mTOR pathway: AKT1, AKT2, AKT3, PTEN, IRS1, IGF1-R, GSK3a, GSK3b, PRAS40, mTOR, p70S6K, TSC2; RAS and p53 isoforms | 10 reactions | A40081 |
Protein quantitation | SureQuant AKT Pathway Relative Quantitation Module | 10 reactions | A40082 | |
Sample prep and Protein quantitation | SureQuant AKT Pathway Multiplex Panel (Relative Quantitation) | 10 reactions | A40080 |
The AKT pathway (phospho) IP-MS kit is used for multiplexed enrichment and quantitation of key phosphorylated proteins in the AKT-mTOR signaling pathway. The quantitation modules enable either relative or absolute quantitation of unique peptides of AKT pathway phospho proteins using LC-MS.
Learn more about AKT pathway (phospho) reagents
Workflow step | Product | Phosphorylated Targets | Unit size | Cat. No. |
---|---|---|---|---|
Sample prep | SureQuant AKT Pathway (Phospho) IP and MS Sample Preparation Module | AKT/mTOR pathway: AKT1 pSer473, AKT2 pSer474, PTEN pSer380, IRS1 pSer312, IGF1-R pTyr1162/1163, GSK3a pSer21, GSK3b pSer9, PRAS40 pThr246, mTOR pSer2448, p70S6K pThr389, TSC2 pSer939; RAS and p53 isoforms | 10 reactions | A40086 |
Protein quantitation | SureQuant AKT Pathway (Phospho) Relative Quantitation Module | 10 reactions | A40087 | |
Sample prep and Protein quantitation | SureQuant AKT Pathway (Phospho) Multiplex Panel (Absolute Quantitation) | 10 reactions | A40088 | |
Sample prep and Protein quantitation | SureQuant AKT Pathway (Phospho) Multiplex Panel (Relative Quantitation) | 10 reactions | A40084 | |
Sample prep and Protein quantitation | SureQuant AKT Pathway (Phospho) Multiplex Panel (Relative Quantitation) | 10 reactions | A40085 |
The AKT isoform relative quantitation kit enables comparative quantitation of AKT1, AKT2, AKT3 isoforms and phosphorylation of AKT using LC-MS.
Learn more about AKT pathway (isoform) reagents
Product | Target proteins | Unit size | Cat. No. |
---|---|---|---|
SureQuant AKT Isoform Relative Quantitation Module | AKT1, AKT2 and AKT3 isoforms | 10 reactions | A40092 |
The RAS isoform or TP53 relative quantitation kit is used for relative quantitation of NRAS, KRAS and HRAS isoforms or native and phosphorylated TP53 target proteins using LC-MS. For sample prep, see Standards and Sample prep tab.
Learn more about RAS isoform and TP53 reagents
Product | Target proteins | Unit size | Cat. No. |
---|---|---|---|
SureQuant RAS Isoform Relative Quantitation Module | NRAS, KRAS and HRAS isoforms | 10 reactions | A40097 |
SureQuant TP53 Panel Relative Quantitation Module | TP53 (native and phosphorylated) | 10 reactions | A40102 |
The MS system suitability standards are used for MS instrument calibration to assess system performance and the phosphopeptide standard is utilized to maximize phosphopeptide identifications. The IP-MS sample prep kits can be used for recovery of low-abundant target proteins, and the EasyPep kits can be used for samples not requiring enrichment.
Learn more about MS standards and sample prep
Workflow step | Product | Proteins/Signaling pathways | Unit size | Cat. No. |
---|---|---|---|---|
Chromatography optimization and system performance for phosphopeptides | SureQuant Phosphopeptide Suitability Standard | Serine, threonine and tyrosine phosphorylated | 50 µL | A51746 |
Phosphopeptide quantitation | SureQuant Multipathway Phosphopeptide Standard | PI3K/AKT/mTOR; EGFR/HER; RAS-MAPK; AMPK; Death/Apoptosis; Stress (p38/SAPK/JNK) | 200 µL | A51745 |
General MS standard and SureQuant sample prep reagents.
Workflow step | Product | Unit size | Cat. No. |
---|---|---|---|
LC-MS system calibration | Pierce LC-MS/MS System Suitability Standard (7 x 5 mixture) | 25 µL | A40010 |
100 µL | A51747 | ||
Sample prep | SureQuant Protein A/G IP-MS Sample Preparation Kit | 20 reactions | A51743 |
Sample prep | SureQuant Streptavidin IP-MS Sample Preparation Kit | 20 reactions | A51744 |
Sample Prep | EasyPep MS sample prep kit | 8 reactions | A45734 |
20 reactions | A40006 | ||
96 reactions | A45733 |
The AKT pathway IP-MS sample preparation kit is used to immuno-enrich total target proteins of AKT-mTOR pathway with subsequent in-solution MS sample preparation. The quantitation module enables relative quantitation of unique peptides of AKT pathway proteins using LC-MS.
Learn more about AKT pathway (total) reagents
Workflow step | Product | Target proteins | Unit size | Cat. No. |
---|---|---|---|---|
Sample prep | SureQuant AKT Pathway IP and MS Sample Preparation Module | AKT/mTOR pathway: AKT1, AKT2, AKT3, PTEN, IRS1, IGF1-R, GSK3a, GSK3b, PRAS40, mTOR, p70S6K, TSC2; RAS and p53 isoforms | 10 reactions | A40081 |
Protein quantitation | SureQuant AKT Pathway Relative Quantitation Module | 10 reactions | A40082 | |
Sample prep and Protein quantitation | SureQuant AKT Pathway Multiplex Panel (Relative Quantitation) | 10 reactions | A40080 |
The AKT pathway (phospho) IP-MS kit is used for multiplexed enrichment and quantitation of key phosphorylated proteins in the AKT-mTOR signaling pathway. The quantitation modules enable either relative or absolute quantitation of unique peptides of AKT pathway phospho proteins using LC-MS.
Learn more about AKT pathway (phospho) reagents
Workflow step | Product | Phosphorylated Targets | Unit size | Cat. No. |
---|---|---|---|---|
Sample prep | SureQuant AKT Pathway (Phospho) IP and MS Sample Preparation Module | AKT/mTOR pathway: AKT1 pSer473, AKT2 pSer474, PTEN pSer380, IRS1 pSer312, IGF1-R pTyr1162/1163, GSK3a pSer21, GSK3b pSer9, PRAS40 pThr246, mTOR pSer2448, p70S6K pThr389, TSC2 pSer939; RAS and p53 isoforms | 10 reactions | A40086 |
Protein quantitation | SureQuant AKT Pathway (Phospho) Relative Quantitation Module | 10 reactions | A40087 | |
Sample prep and Protein quantitation | SureQuant AKT Pathway (Phospho) Multiplex Panel (Absolute Quantitation) | 10 reactions | A40088 | |
Sample prep and Protein quantitation | SureQuant AKT Pathway (Phospho) Multiplex Panel (Relative Quantitation) | 10 reactions | A40084 | |
Sample prep and Protein quantitation | SureQuant AKT Pathway (Phospho) Multiplex Panel (Relative Quantitation) | 10 reactions | A40085 |
The AKT isoform relative quantitation kit enables comparative quantitation of AKT1, AKT2, AKT3 isoforms and phosphorylation of AKT using LC-MS.
Learn more about AKT pathway (isoform) reagents
Product | Target proteins | Unit size | Cat. No. |
---|---|---|---|
SureQuant AKT Isoform Relative Quantitation Module | AKT1, AKT2 and AKT3 isoforms | 10 reactions | A40092 |
The RAS isoform or TP53 relative quantitation kit is used for relative quantitation of NRAS, KRAS and HRAS isoforms or native and phosphorylated TP53 target proteins using LC-MS. For sample prep, see Standards and Sample prep tab.
Learn more about RAS isoform and TP53 reagents
Product | Target proteins | Unit size | Cat. No. |
---|---|---|---|
SureQuant RAS Isoform Relative Quantitation Module | NRAS, KRAS and HRAS isoforms | 10 reactions | A40097 |
SureQuant TP53 Panel Relative Quantitation Module | TP53 (native and phosphorylated) | 10 reactions | A40102 |
The MS system suitability standards are used for MS instrument calibration to assess system performance and the phosphopeptide standard is utilized to maximize phosphopeptide identifications. The IP-MS sample prep kits can be used for recovery of low-abundant target proteins, and the EasyPep kits can be used for samples not requiring enrichment.
Learn more about MS standards and sample prep
Workflow step | Product | Proteins/Signaling pathways | Unit size | Cat. No. |
---|---|---|---|---|
Chromatography optimization and system performance for phosphopeptides | SureQuant Phosphopeptide Suitability Standard | Serine, threonine and tyrosine phosphorylated | 50 µL | A51746 |
Phosphopeptide quantitation | SureQuant Multipathway Phosphopeptide Standard | PI3K/AKT/mTOR; EGFR/HER; RAS-MAPK; AMPK; Death/Apoptosis; Stress (p38/SAPK/JNK) | 200 µL | A51745 |
General MS standard and SureQuant sample prep reagents.
Workflow step | Product | Unit size | Cat. No. |
---|---|---|---|
LC-MS system calibration | Pierce LC-MS/MS System Suitability Standard (7 x 5 mixture) | 25 µL | A40010 |
100 µL | A51747 | ||
Sample prep | SureQuant Protein A/G IP-MS Sample Preparation Kit | 20 reactions | A51743 |
Sample prep | SureQuant Streptavidin IP-MS Sample Preparation Kit | 20 reactions | A51744 |
Sample Prep | EasyPep MS sample prep kit | 8 reactions | A45734 |
20 reactions | A40006 | ||
96 reactions | A45733 |
We provide complete kits and stand-alone reagents for MS sample preparation and multiplexed enrichment of key signaling pathway proteins. Sample prep for SureQuant analysis can be performed with or without enrichment:
The SureQuant workflow consists of the following steps:
Figure 1. Pathway analysis using Surequant workflow. A. IP-MS/SureQuant workflow uses multiplexed IP enrichment followed by MS sample preparation. B. SureQuant sample preparation using EasyPep Maxi for generation of peptide digests for unenriched samples. Both SureQuant workflows enable multiplexed quantitation of target proteins.
The AKT/mTOR and RAS/MAPK signaling pathways represent key mechanisms involved in the regulation of cell survival, proliferation, and motility [1] (Figure 2). The cross-talk between two pathways plays a central role in tumor progression and anti-cancer drug resistance [2] (Figure 2). The quantitation of pathway protein expression and modifications are critical for characterization of disease, monitoring cancer progression, and determining treatment response.
Figure 2. Crosstalk between AKT/mTOR and RAS/ERK Pathways.
Protein kinase B (PKB or AKT) refers to a set of three serine/threonine-specific protein kinases that play a crucial role in cell metabolism, growth, proliferation, and survival. The activation of AKT is controlled by a multi-step process that involves phosphoinositide-3-kinase (PI3K) [3].
Figure 3. Relative quantitation of AKT/mTOR pathway proteins in in mammalian cells. A549 cells (human adenocarcinoma cell line) were treated with IGF1 and the relative quantitation of AKT/mTOR pathway proteins was determined using the SureQuant AKT Pathway Multiplex Panel (Relative Quantitation). The pathway proteins were enriched through multiplex immunoprecipitation followed by nanoLC-PRM/MS analyses on a QExactive HF-Orbitrap mass spectrometer.
Figure 4. Absolute quantitation of AKT/mTOR phosphor pathway proteins in mammalian cells. MCF7 cells (human breast cancer cell line) were treated with IGF1 and the absolute quantitation of AKT/mTOR pathway proteins was determined using the SureQuant AKT Pathway Multiplex Panel (Absolute Quantitation). The pathway proteins were enriched through multiplex immunoprecipitation followed by nanoLC-PRM/MS analyses on a Q Exactive HF-Orbitrap mass spectrometer. All targets were quantified by standard curve generated for each target peptides included in the Quantitation Modules.
Figure 5. Relative quantitation of AKT isoforms in mammalian cells. A549 cells (human adenocarcinoma cell line) were treated with IGF1 and the relative quantitation of AKT isoforms was determined using the SureQuant AKT Isoform Panel (Relative Quantitation). The AKT isoforms were enriched through multiplex immunoprecipitation followed by nanoLC-PRM/MS analyses on a QExactive HF-Orbitrap mass spectrometer.
RAS (GTPase protein) is a key member of the MAPK and PI3K signaling pathways involved in cell growth and proliferation [4].
RAS isoforms (HRAS, NRAS, and KRAS) are mutated in 30% of human cancers The Tumor suppressor protein, TP53 acts as a negative checkpoint regulator for abnormal cell signaling [5]. Many genetic mutations in cancer cells can alter protein expression of RAS and TP53 pathway components.
The SureQuant RAS or TP53 Relative quantitation module enables quantitation of RAS isoforms (HRAS, NRAS, and KRAS) or native and phosphorylated TP53 protein, in a single assay for assessment of normal vs. abnormal pathway signaling (Figure 6A and 6B). For IP-MS sample prep of RAS/TP53, please refer to the section Sample prep for SureQuant analysis.
A.
B.
Figure 6. Relative quantitation of RAS isoforms/TP53 in mammalian cells. HCT116 cells (human colon cancer cell line) treated with IGF1 and untreated BT549 (human breast cancer cell line) were used to measure the relative quantitation of RAS isoforms (A.) and TP53 (B.) using the SureQuant RAS Isoform Panel (Relative Quantitation). The RAS isoforms and TP53 were enriched through multiplex immunoprecipitation followed by nanoLC-PRM/MS analyses on a Q Exactive HF-Orbitrap mass spectrometer.
Figure 7. SureQuant Phosphopeptide Suitability Standard. Base peak chromatogram (top) and Skyline chromatogram (bottom) of SureQuant Phosphopeptide Suitability Standard (200 fmol) were separated using a Dionex UltiMate 3000 RSLCnano System and Thermo Scientific™ Acclaim PepMap RSLC C18 column (2 μm x 75 μm x 50 cm) with a 2–35% gradient (Buffer A: 0.1% FA in water, Buffer B: 0.1% FA in 100% acetonitrile) at 300 nL/min for 60 minutes. Detection was performed on a Thermo Scientific Q Exactive HF-Orbitrap Mass Spectrometer.
The SureQuant Multipathway Phosphopeptide Standard contains an optimized mixture of 131 isotopically labeled phosphopeptides selected to cover biologically relevant phosphorylation sites for 89 key proteins from seven signaling pathways including EGFR/HER, RAS-MAPK, PI3K/AKT/mTOR, AMPK, death/apoptosis, and stress (p38/SAPK/JNK). The workflow for sample analysis using SureQuant Multipathway standard is shown in Figure 8(A). The use of Multipathway Standard with phosphopeptide enrichment enables simultaneous monitoring and quantitation of target proteins in a single sample for assessment of normal and abnormal signaling pathway activity (Figure 8(B)).
A.
B.
Figure 8. Multipathway Phosphopeptide Standard Method Optimization. A. Workflow. B. Heat map of relative levels of phosphopeptides compared between treated cell lysates (left). Changes in specific phosphopeptides (right). One μg of treated cell lines was incubated with High-Select Fe-NTA magnetic beads. Prior to enrichment, 1 pmol of the SureQuant Multipathway Phosphopeptide Standard was spiked into the lysate. PRM analysis was performed using the Dionex UltiMate 3000 RSLCnano System and Q Exactive HF Hybrid Quadrupole-Orbitrap Mass Spectrometer, with subsequent analysis in Skyline software using the average total area. A: HCT116/IGF; B: MCF7/IGF;
C: LNCAP/IGF; D: A431/EGF; E: HepG2/Ins.
A.
B.
Figure 9. Pierce LC-MS/MS System Suitability Standard (7x5 mix). A. Composition of Pierce LC-MS/MS System Suitability Standard (7 x 5 mix). B. For MS analysis, the standards were analyzed on a Thermo Scientific UltiMate™ 3000 RSLCnano System and Q Exactive HF system using an EASY-Spray HPLC Column with a 3–30% gradient of Buffer B (0.1% formic acid, 99.9% acetonitrile) and Buffer A (0.1% formic acid) at
0.3 µL/min.
Explore our webinars around targeted mass spectrometry. Click on targeted proteomics section to find these webinars that discuss targeted mass spectrometry workflows and its applications to quantitate proteins of interest. Various strategies to reduce sample complexity through improved sample preparation and enrichment, providing guidance towards targeted MS-assay development, will be introduced.
New tools for improved proteomics results
Custom peptide synthesis
Quantitative Analysis of Ras and AKT Signaling Pathways using a SureQuant Targeted MS Workflow
For Research Use Only. Not for use in diagnostic procedures.