Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Ion concentration measurement or ion-specific (ISE) measurements can be performed in every laboratory for a variety of sample types including water, food and beverage, pharmaceuticals, and biological samples.
To evaluate a sample's ion-specific performance, the best resource is slope S, also known from pH measurement. Whether you're looking to test ISE measurements through the direct method, dilution method, matrix match method, known addition method, or matrix factor method, our robust portfolio of ion-specific meters, electrodes, standards, and solutions are known for delivering accurate and reproducible ISE measurement results.
The ion selective electrode (ISE) is a useful and versatile sensor for testing ions in various types of samples, such as environmental, agricultural, industrial, biotechnical, pharmaceutical, food, wastewater, drinking water, and others. Typical ions of interest include ammonia, fluoride, nitrate, chloride, calcium, sodium, potassium, silver, sulfide, iodide, bromide, lead, cadmium, copper, and others.
|
|
|
|
To make an accurate measurement using an ISE, a suitable ISE method should be selected according to specific sample conditions.
Regulations vary between ion specific measurements, and it’s critical that you have instruments and electrodes that allow you to stay complaint with your industry standards. Below is a list of international standards for regulatory compliance requirements for a variety of industries.
International standards for regulatory compliance requirements:
Parameter | EPA | SM | ASTM | ISO | China MEP | USP | EP | AOAC | Other |
---|---|---|---|---|---|---|---|---|---|
pH | EPA 150.1 | 4500-H+(B) | D1293 (A,B) | 10523 | GB/T 6920 | <791> | 2.2.3 | 973.41 | FDA - 21 CFR 114.90 |
pH of Soil/Solid Waste | SW-846 9040C & 9045D | D4972 | 10390 | GB/T15555 | 994.16 - 994.18 | USDA NRCS | |||
Conductivity | EPA 120.1; SW-846 9050A | 2510 (B) | D1125 (A) | 7888 | n/a | <645> | 2.2.38 | 973.40 | PSS-78 (salinity) |
Dissolved Oxygen | 4500-O (G) | D888 (B, C) | 17289; 5814 | HJ506 | |||||
BOD | 5210 (B) | 5815 | HJ505 | 973.44 | |||||
Fluoride | SW-846 9214 | 4500-F (C ) | D1179 (B) | 10359 | GB7484 | ||||
Ammonia | 4500-NH3 (D, E) | D1426 (B) | 6778 | ||||||
Nitrate | Orion 601; SW-846 9210A | 4500-NO3 (D) | |||||||
Sulfide | SW-846 9215 | 4500-S2 (G) | D4658 | ||||||
Cyanide | SW-846 9213 | 4500-CN (F) | D2036 (A) | ||||||
Chloride | SW-846 9212 | 4500-Cl (D) | D512 (C) | GB11896 | |||||
Bromide | SW-846 9211 |
SM: Standard Methods for the Examination of Water and Wastewater. APHA, AWWA, WEF. | |
ASTM: American Society for the Testing and Materials | |
ISO: International Organization for Standardization | |
USP: United States Pharmacopeia | |
EP: European Pharmacopeia | |
China MEP: China Ministry of Environmental Protection | |
AOAC: Association of Official Analytical Chemists | |
NRCS: Natural Resources Conservation Service | |
PSS-78: Practical Salinity Scale of 1978 | |
FDA: U.S. Food and Drug Administration | |
USDA: United Stated Department of Agriculture |
Meet your sample analysis challenges with a combination of Thermo Scientific meters, electrodes, standards, and solutions, ideal for use with the following applications. Click on an icon below to learn more about these products.
The accuracy and reliability of your ISE measurements depend on the instrumentation you use. Learn more about how you can identify the best match based on your required features, performance, specifications, and budget
|
We offer electrodes, standards and electrode storage solutions, electrode cleaning solutions, and electrode filling solutions for your ISE measurement needs, Find te solutions that you need for your process. |
Validation and qualification (IQ/OQ) services for Thermo Scientific Orion bench and portable meters are currently available through Unity Lab Services in the United States ›
Perform your routine pH and ion concentration (ISE) measurements in the lab or take your measurements outdoors without sacrificing accuracy and reliability. Thermo Scientific Orion Star A320 series of portable pH and ISE meters offer a rugged, waterproof design for dependable performance on location.
Rely on Orion ion selective electrodes for superior performance and reproducible results. Obtain accuracy by leveraging NIST-traceable calibration standards along with ionic strength adjusters, reagents, and fill solutions for all ISE measurement needs.
Premium | Advanced | Basic | |
---|---|---|---|
Orion Versa Star Pro pH/ISE (VSTAR40 series) | Orion Dual Star pH/ISE Dual Channel (2115000 series) | Orion Star A214 pH/ISE (STARA2140 series) | |
Versatile, high-performance laboratory measurement system | Easy to use, dependable laboratory meters | Economical, simplified laboratory meters | |
Ideal for applications in: | Pharmaceuticals, biotechnology, food and beverage, industrial | Water, wastewater, chemical, contract testing | Academic, environmental, power |
pH range | –2.000 to 20.000 | –2.000 to 19.999 | –2.000 to 20.000 |
pH resolution | 0.001/0.01/0.1 | 0.001/0.01/0.1 | 0.001/0.01/0.1 |
pH calibration points | Up to 6 | Up to 6 | Up to 5 |
mV, RmV modes | Yes | Yes | Yes |
ISE Ion Concentration Range | 0.0001 to 19990 | 0.0001 to 19990 | 0.0001 to 19990 |
Incremental techniques | Single known addition or subtraction, double known addition or subtraction, analyte (sample) addition or subtraction | Single known addition or subtraction, double known addition or subtraction | --- |
Temperature Range | -5 to 105°C 22 to 221°F | -5 to 105°C 23 to 221°F | -5 to 105°C 23 to 221°F |
Number of channels | 4, customizable with modules | 2 | 1 |
Stirrer probe inputs | 2 | 1 | 1 |
Data log | 2,000 with date/time | 1,000 with date/time | 2,000 with date/time |
Calibration log | 30 per mode | 10 | 10 |
Identification options | Electrode ID, sample ID, user ID | Electrode ID, sample ID | Sample ID, user ID |
Data export options | USB (2), RS232 | USB, RS232 | USB, RS232 |
Power supply | Universal, 100–240VAC, 50–60Hz (Cat. No. STARA-PWR) | Universal, 100–240VAC, 50–60Hz (Cat. No. 1010003) | Universal, 100–240VAC, 50–60Hz (Cat. No. 1010003) or 4 AA batteries |
Enhance your productivity with accessories for your benchtop and portable meters. Meter Accessories › |
Premium | Advanced | |
---|---|---|
Orion Star A329 pH/ISE (STARA3290 series) | Orion Star A324 pH/ISE (STARA3240 series) | |
Versatile, powerful, multiparameter meter | Rugged and dependable multi-parameter meter | |
Ideal for applications in: | Industrial—waste water, drinking water, food & beverage; Environmental—lakes, ponds | Industrial—waste water, cooling tanks; Environmental—lakes, ponds |
pH range | –2.000 to 20.000 | –2.000 to 20.000 |
pH resolution | 0.1/0.01/0.001 | 0.1/0.01/0.001 |
pH relative accuracy | ±0.002 | ±0.002 |
pH calibration points | Up to 5 | Up to 5 |
Range (mV) | ±2000.0 mV | ±2000.0 mV |
Resolution (mV) | 0.1 mV | 0.1 mV |
Relative accuracy | ±0.2 mV or ±0.05% of reading, whichever is greater | ±0.2 mV or ±0.05% of reading, whichever is greater |
EH ORP mode | Yes | Yes |
Range (ISE) | 0.0001 to 19,900 | 0.0001 to 19,900 |
Calibration points | Up to 5 | Up to 5 |
Range (temperature) | –5 to 105ºC, 23 to 221ºF | –5 to 105ºC, 23 to 221ºF |
Number of datalogs | 5,000 with time and date stamp | 5,000 with time and date stamp |
Data export options | RS232, USB | RS232, USB |
AC adapter | Optional—universal, 100–240VAC | Optional—universal, 100-240VAC |
Battery power | Included—4AAs | Included—4 AAs |
Battery life | 800 hrs | 800 hrs |
Enhance your productivity with accessories for your benchtop and portable meters. Meter Accessories › |
Premium | Advanced | Basic | |
---|---|---|---|
Orion Versa Star Pro pH/ISE (VSTAR40 series) | Orion Dual Star pH/ISE Dual Channel (2115000 series) | Orion Star A214 pH/ISE (STARA2140 series) | |
Versatile, high-performance laboratory measurement system | Easy to use, dependable laboratory meters | Economical, simplified laboratory meters | |
Ideal for applications in: | Pharmaceuticals, biotechnology, food and beverage, industrial | Water, wastewater, chemical, contract testing | Academic, environmental, power |
pH range | –2.000 to 20.000 | –2.000 to 19.999 | –2.000 to 20.000 |
pH resolution | 0.001/0.01/0.1 | 0.001/0.01/0.1 | 0.001/0.01/0.1 |
pH calibration points | Up to 6 | Up to 6 | Up to 5 |
mV, RmV modes | Yes | Yes | Yes |
ISE Ion Concentration Range | 0.0001 to 19990 | 0.0001 to 19990 | 0.0001 to 19990 |
Incremental techniques | Single known addition or subtraction, double known addition or subtraction, analyte (sample) addition or subtraction | Single known addition or subtraction, double known addition or subtraction | --- |
Temperature Range | -5 to 105°C 22 to 221°F | -5 to 105°C 23 to 221°F | -5 to 105°C 23 to 221°F |
Number of channels | 4, customizable with modules | 2 | 1 |
Stirrer probe inputs | 2 | 1 | 1 |
Data log | 2,000 with date/time | 1,000 with date/time | 2,000 with date/time |
Calibration log | 30 per mode | 10 | 10 |
Identification options | Electrode ID, sample ID, user ID | Electrode ID, sample ID | Sample ID, user ID |
Data export options | USB (2), RS232 | USB, RS232 | USB, RS232 |
Power supply | Universal, 100–240VAC, 50–60Hz (Cat. No. STARA-PWR) | Universal, 100–240VAC, 50–60Hz (Cat. No. 1010003) | Universal, 100–240VAC, 50–60Hz (Cat. No. 1010003) or 4 AA batteries |
Enhance your productivity with accessories for your benchtop and portable meters. Meter Accessories › |
Premium | Advanced | |
---|---|---|
Orion Star A329 pH/ISE (STARA3290 series) | Orion Star A324 pH/ISE (STARA3240 series) | |
Versatile, powerful, multiparameter meter | Rugged and dependable multi-parameter meter | |
Ideal for applications in: | Industrial—waste water, drinking water, food & beverage; Environmental—lakes, ponds | Industrial—waste water, cooling tanks; Environmental—lakes, ponds |
pH range | –2.000 to 20.000 | –2.000 to 20.000 |
pH resolution | 0.1/0.01/0.001 | 0.1/0.01/0.001 |
pH relative accuracy | ±0.002 | ±0.002 |
pH calibration points | Up to 5 | Up to 5 |
Range (mV) | ±2000.0 mV | ±2000.0 mV |
Resolution (mV) | 0.1 mV | 0.1 mV |
Relative accuracy | ±0.2 mV or ±0.05% of reading, whichever is greater | ±0.2 mV or ±0.05% of reading, whichever is greater |
EH ORP mode | Yes | Yes |
Range (ISE) | 0.0001 to 19,900 | 0.0001 to 19,900 |
Calibration points | Up to 5 | Up to 5 |
Range (temperature) | –5 to 105ºC, 23 to 221ºF | –5 to 105ºC, 23 to 221ºF |
Number of datalogs | 5,000 with time and date stamp | 5,000 with time and date stamp |
Data export options | RS232, USB | RS232, USB |
AC adapter | Optional—universal, 100–240VAC | Optional—universal, 100-240VAC |
Battery power | Included—4AAs | Included—4 AAs |
Battery life | 800 hrs | 800 hrs |
Enhance your productivity with accessories for your benchtop and portable meters. Meter Accessories › |