Invitrogen Precast Protein Gel Welcome packs for Mini and Midi sized gels and included components

Protein Gels welcome packs are cost-saving product combinations that contain all you need for outstanding protein separation. They include mini and midi format gels, buffers and reagents, as well as our Mini or Midi gel tank, with or without blot modules.

Ordering information  Find the right gel for your protein

Don’t need a tank? See our Protein Gel Resupply Packs to restock on protein gels and gel electrophoresis reagents.


Find the right welcome pack gel chemistry for your research needs

The choice of whether to use one chemistry or another depends on the abundance of the target protein, the size of the protein, and the downstream application.

For separation of a broad range of proteins, two chemistries, Bis-Tris and Tris-glycine, have been optimized for performance and long shelf life. Select Bis-Tris gel chemistry for low abundance target proteins or when downstream applications require high protein integrity, such as posttranslational modification analysis, mass spectrometry, or sequencing. Our Invitrogen Bolt Bis-Tris Plus Mini Gels build on the legacy of the highly referenced Invitrogen NuPAGE Bis-Tris Gels and have a wedge-shaped sample well for loading up to 2X greater sample volumes.

To separate high-abundance proteins, select our robust Invitrogen Novex Tris-Glycine Mini Gels or Novex Tris-Glycine Plus Midi Gels, which offer maximum protein separation and crisp, straight bands. Tris-acetate gel chemistry, offered by Invitrogen NuPAGE Tris-Acetate Gels, is recommended for the separation of high molecular weight proteins up to 500 kDa. Novex Tricine Gels are available in a mini gel format and are designed for the separation of low molecular weight proteins and peptides.

Mini or midi gel tank?

The choice of mini of midi tank depends on your sample throughput needs. Invitrogen mini gels are available with up to 15 sample wells and Invitrogen midi gels are available with up to 26 sample wells. The Mini Gel Tank is compatible with all mini gels and can accommodate up to two gels per run. The streamlined, side-by-side tank design configuration enables convenient sample loading and enhanced viewing during use.

Welcome pack with Mini Gel Tank
Welcome pack with Mini Gel Tank

If you have higher throughput sample processing needs, the Invitrogen SureLock Tandem Midi Gel Tank is designed for easy and consistent vertical protein gel electrophoresis of 1 or 2 Invitrogen midi gels. The SureLock Tandem Midi Gel Tank is compatible with all NuPAGE and Novex midi gels and can accommodate up to two gels per run.

Welcome pack with SureLock Tandem Midi Gel Tank
Welcome pack with SureLock Tandem Midi Gel Tank

NEW Protein gel welcome packs, now featuring Mini Blot Modules, are available.

The Mini Blot Module is designed to seamlessly integrate with the Mini Gel tank. The 2-in-1 design allows efficient gel electrophoresis and protein transfer in the same tank. Only 220 mL of transfer buffer per gel needed.

Precast Gel Welcome Pack with Blot modules
Gel tank, transfer modules, box of precast gels, bottles of buffers and reagents for protein electrophoresis.

Our protein gels are also compatible with the SureLock Midi Transfer Module, Invitrogen Power Blotter, iBlot 3 Gel Transfer Device, iBind Western Device, and iBind Flex Western Device for optimal transfer and detection of proteins.

Ordering information

Bolt Welcome Pack

The Bolt Welcome Pack contains all components required to perform protein gel electrophoresis using Bolt Bis-Tris Plus gels. Besides the Bolt Bis-Tris Plus gels and buffers, this convenient package even contains the Mini Gel Tank with or without Mini Blot modules, and our PageRuler Pre-Stained Protein Ladder for easy protein separation of broad molecular weights.

The Bolt Welcome Pack contains:

  • Mini Gel Tank
  • Bolt Bis-Tris Plus gels (2 boxes, 20 gels)
  • Bolt MES Running Buffer (20X)
  • Bolt LDS Sample Buffer (4X)
  • Bolt Sample Reducing Agent (10X)
  • PageRuler Plus Prestained Protein Ladder, 10 to 250 kDa
  • NEW Packs including Mini Blot Modules available

About Bolt Bis-Tris Plus Gels:

Bolt Bis-Tris Plus gels are precast polyacrylamide gels designed for optimal separation of broad molecular weights under denaturing conditions. Designed using neutral-pH formulation, the Bolt Bis-Tris Plus gel chemistry minimizes protein modifications or degradation that can result in poor band resolution.

The WedgeWell design allows detection of proteins in very dilute samples or visualization of low-abundance proteins.

Bolt gels are an excellent choice for routine protein separation needs or when the target protein is of low abundance and when preserving protein integrity is crucial as in posttranslational modification analysis, mass spectrometry, or sequencing. Bolt Bis-Tris Plus gels come in four polyacrylamide concentrations: 8, 10, 12, and 4–12% gradient and multiple well formats.

NuPAGE Bis-Tris Welcome Packs

The NuPAGE Bis-Tris Welcome Packs are available in mini and midi gel formats and contain all components required to perform protein gel electrophoresis using NuPAGE Bis-Tris mini or midi gels. Besides the NuPAGE Bis-Tris gels and buffers, these convenient packages even contain a Mini Gel Tank with or without Mini Blot modules, or SureLock Tandem Midi Gel Tank, and our PageRuler Pre-Stained Protein Ladder for easy protein separation of broad molecular weights.

The NuPAGE Bis-Tris Welcome Packs contain:

  • Mini Gel Tank or SureLock Tandem Midi Gel Tank
  • NuPAGE Bis-Tris mini or midi gels (2 boxes, 20 gels)
  • NuPAGE MES SDS Running Buffer (20X)
  • NuPAGE LDS Sample Buffer (4X)
  • NuPAGE Sample Reducing Agent (10X)
  • PageRuler Plus Prestained Protein Ladder, 10 to 250 kDa
  • NEW Packs including Mini Blot Modules available

About NuPAGE Bis-Tris gels:

Bis-Tris gel chemistry maintains proteins in a neutral-pH environment preserving protein integrity, resulting in sharp, straight bands. NuPAGE Bis-Tris gels provide the benefits of Bis-Tris chemistry and have been proven reliable in over 20,000 publications. Rely on the tried, trusted, and true NuPAGE Bis-Tris gels for outstanding broad-range protein resolution. NuPAGE Bis-Tris gels are available in three polyacrylamide concentrations: 10, 12, and 4–12% gradient and multiple well formats.

Mini Gels

Midi Gels

Novex Tris-Glycine Welcome Packs

The Novex Tris-Glycine Welcome Packs contains all components required to perform protein gel electrophoresis using the Novex Tris-Glycine Mini Gels or Novex Tris-Glycine Plus Midi Gels. In addition to the Novex Tris-Glycine Mini Gels or Novex Tris-Glycine Plus Midi Gels and buffers, this convenient package even contains a Mini Gel Tank with or without Mini Blot modules, or SureLock Tandem Midi Gel Tank and our PageRuler Pre-Stained Protein Ladder for easy protein separation of broad molecular weights.

The Novex Tris-Glycine Welcome Packs contains:

  • Mini Gel Tank or SureLock Tandem Midi Gel Tank
  • Novex Tris-Glycine Mini Gels, WedgeWell format or Novex Tris-Glycine Plus Midi Gels (2 boxes, 20 gels)
  • Novex Tris-Glycine SDS Running Buffer (10X)
  • Novex Tris-Glycine SDS Sample Buffer (2X)
  • NuPAGE Sample Reducing Agent (10X)
  • PageRuler Plus Prestained Protein Ladder, 10 to 250 kDa
  • NEW Packs including Mini Blot Modules available

About Novex Tris-Glycine Gels:

The Tris-glycine gel chemistry is robust for a wide range of sample types. Based on the traditional Laemmli system, Novex Tris-Glycine gels provide high-quality performance and separation of a wide range of proteins into well-resolved bands and are compatible with samples containing detergents and high salt concentrations. The Novex Tris-Glycine mini gels, WedgeWell format, feature easier-to-load, larger-capacity wells that let you load up to 60 μL of sample.

Novex Tris-Glycine mini gels are offered in nine polyacrylamide concentrations: 6, 8, 10, 12, 14, and 16 percent, and 4–12%, 4–20%, and 8–16% gradient and multiple well formats. Novex Tris-Glycine Plus midi gels feature a conventional sample well and are offered in five polyacrylamide concentrations: 10 and 12 percent, and 4–12%, 4–20%, and 8–16% gradient and multiple well formats.

Mini Gels

Midi Gels

NuPAGE Tris-Acetate Welcome Packs

The NuPAGE Tris-Acetate Welcome Packs contain all components required to perform protein gel electrophoresis using NuPAGE Tris-Acetate mini or midi gels.In addition to the NuPAGE Tris-Acetate mini or midi gels and buffers, this convenient package even contains a Mini Gel Tank with or without Mini Blot modules, or SureLock Tandem Midi Gel Tank and our HiMark Pre-Stained Protein Standard for easy high molecular weight protein separation.

The NuPAGE Tris-Acetate Welcome Packs contain:

  • Mini Gel Tank or SureLock Tandem Midi Gel Tank
  • NuPAGE Tris-Acetate mini or midi gels (2 boxes, 20 gels)
  • NuPAGE Tris-Acetate SDS Running Buffer (20X)
  • NuPAGE LDS Sample Buffer (4X)
  • NuPAGE Sample Reducing Agent (10X)
  • HiMark Pre-stained Protein Standard
  • NEW Packs including Mini Blot Modules available

About NuPAGE Tris-Acetate Gels:

The Tris-Acetate gel chemistry enables optimal separation of high molecular weight proteins when used with an SDS running buffer. NuPAGE Tris-Acetate gels offer an environment of pH 8.1 that minimizes protein modifications and results in sharper bands. NuPAGE Tris-Acetate gels can also be run with Novex Tris-Glycine Native Running Buffer to resolve native proteins more effectively than a Tris-glycine gel system.

The NuPAGE Tris-Acetate gels are available in two polyacrylamide concentrations: 7 and 3–8% gradient and multiple well formats.

Mini Gels

Midi Gels

Novex Tricine Welcome Pack

The Novex Tricine Welcome Pack contains all components required to perform protein gel electrophoresis using Novex Tricine gels. Besides the Novex Tricine gels and buffers, this convenient package even contains the Mini Gel Tank with or without Mini Blot modules, and our Spectra Multicolor Low Range Protein Ladder for easy low molecular weight protein separation.

The Novex Tricine Welcome Pack contains:

  • Mini Gel Tank
  • Novex Tricine Mini Gels (2 boxes, 20 gels)
  • Novex Tricine SDS Running Buffer (10X)
  • Novex Tricine SDS Sample Buffer (2X)
  • NuPAGE Sample Reducing Agent (10X)
  • Spectra Multicolor Low Range Protein Ladder
  • NEW Packs including Mini Blot Modules available

About Novex Tricine gels:

Tricine gel chemistry enables the optimum separation of low molecular weight proteins and peptides. Novex Tricine gels are high-resolution gels for peptide and low molecular weight protein analyses. The Novex Tricine gel system is a modification of the Tris-glycine system in which tricine replaces glycine in the running buffer. This system uses a discontinuous buffer system specifically designed for the resolution of low molecular weight proteins.

The Novex Tricine gels are offered in three polyacrylamide concentrations: 10, 16 and 10–20% gradient and multiple well formats.

Welcome Packs for Protein Expression

Protein gels welcome packs for protein expression are available in mini gel and midi gel formats designed for use in protein expression experiments and subsequent purification steps. In addition to the components included with the standard protein gels welcome packs, welcome packs for protein expression include SimplyBlue SafeStain to enable fast separation and gel staining so that you can quickly assess your expression and purification results.

The Bolt Mini Bis-Tris and NuPAGE Midi Bis-Tris Welcome Packs are designed to be used for any protein expression application or expression system, such as our Expi Transient Protein Expression Systems.

The protein gels welcome packs for protein expression contain:

  • Mini Gel Tank or SureLock Tandem Midi Gel Tank
  • Invitrogen precast Bolt Bis-Tris Plus mini (12-well) or NuPAGE Bis-Tris midi (20-well) 4–12% gradient protein gels (2 boxes, 20 gels)
  • MES Running buffer (20X)
  • LDS sample buffer (4X)
  • Bolt or NuPAGE sample reducing agent (10X)
  • PageRuler Plus Prestained Protein Ladder, 10 to 250 kDa
  • SimplyBlue SafeStain, 1L

SimplyBlue SafeStain, included in the protein gels welcome packs for protein expression, is a ready-to-use, fast, sensitive, and safe Coomassie G-250 stain for visualizing protein bands on polyacrylamide gels. The SimplyBlue SafeStain protocol is easy to perform and can be completed in less than three hours. For added speed, a simple microwave procedure can be completed in 12 minutes. Destaining is not required but may be performed with deionized water to achieve maximum sensitivity. This stain is completely non-hazardous and does not require methanol or acetic acid fixatives or destains, creating a healthier lab environment.

XCell SureLock Welcome Packs

The XCell SureLock Mini-Cell Welcome Packs contain all components required to perform gel electrophoresis using the XCell SureLock Mini-Cell and Invitrogen pre-cast gels in four different gel chemistries. Each Welcome pack also include a compatible prestained protein ladder.

About the XCell SureLock Mini-Cell

The XCell SureLock Mini-Cell is a vertical mini-protein gel electrophoresis system compatible with all Invitrogen mini precast gels and Surecast handcast gels. The Mini-Cell is simple, sturdy, and easy to use. Each XCell SureLock Mini-Cell can accommodate up to two gels per run. Run times may vary depending on the gel chemistry and buffer conditions used.

Bolt Welcome Pack

The Bolt Welcome Pack contains all components required to perform protein gel electrophoresis using Bolt Bis-Tris Plus gels. Besides the Bolt Bis-Tris Plus gels and buffers, this convenient package even contains the Mini Gel Tank with or without Mini Blot modules, and our PageRuler Pre-Stained Protein Ladder for easy protein separation of broad molecular weights.

The Bolt Welcome Pack contains:

  • Mini Gel Tank
  • Bolt Bis-Tris Plus gels (2 boxes, 20 gels)
  • Bolt MES Running Buffer (20X)
  • Bolt LDS Sample Buffer (4X)
  • Bolt Sample Reducing Agent (10X)
  • PageRuler Plus Prestained Protein Ladder, 10 to 250 kDa
  • NEW Packs including Mini Blot Modules available

About Bolt Bis-Tris Plus Gels:

Bolt Bis-Tris Plus gels are precast polyacrylamide gels designed for optimal separation of broad molecular weights under denaturing conditions. Designed using neutral-pH formulation, the Bolt Bis-Tris Plus gel chemistry minimizes protein modifications or degradation that can result in poor band resolution.

The WedgeWell design allows detection of proteins in very dilute samples or visualization of low-abundance proteins.

Bolt gels are an excellent choice for routine protein separation needs or when the target protein is of low abundance and when preserving protein integrity is crucial as in posttranslational modification analysis, mass spectrometry, or sequencing. Bolt Bis-Tris Plus gels come in four polyacrylamide concentrations: 8, 10, 12, and 4–12% gradient and multiple well formats.

NuPAGE Bis-Tris Welcome Packs

The NuPAGE Bis-Tris Welcome Packs are available in mini and midi gel formats and contain all components required to perform protein gel electrophoresis using NuPAGE Bis-Tris mini or midi gels. Besides the NuPAGE Bis-Tris gels and buffers, these convenient packages even contain a Mini Gel Tank with or without Mini Blot modules, or SureLock Tandem Midi Gel Tank, and our PageRuler Pre-Stained Protein Ladder for easy protein separation of broad molecular weights.

The NuPAGE Bis-Tris Welcome Packs contain:

  • Mini Gel Tank or SureLock Tandem Midi Gel Tank
  • NuPAGE Bis-Tris mini or midi gels (2 boxes, 20 gels)
  • NuPAGE MES SDS Running Buffer (20X)
  • NuPAGE LDS Sample Buffer (4X)
  • NuPAGE Sample Reducing Agent (10X)
  • PageRuler Plus Prestained Protein Ladder, 10 to 250 kDa
  • NEW Packs including Mini Blot Modules available

About NuPAGE Bis-Tris gels:

Bis-Tris gel chemistry maintains proteins in a neutral-pH environment preserving protein integrity, resulting in sharp, straight bands. NuPAGE Bis-Tris gels provide the benefits of Bis-Tris chemistry and have been proven reliable in over 20,000 publications. Rely on the tried, trusted, and true NuPAGE Bis-Tris gels for outstanding broad-range protein resolution. NuPAGE Bis-Tris gels are available in three polyacrylamide concentrations: 10, 12, and 4–12% gradient and multiple well formats.

Mini Gels

Midi Gels

Novex Tris-Glycine Welcome Packs

The Novex Tris-Glycine Welcome Packs contains all components required to perform protein gel electrophoresis using the Novex Tris-Glycine Mini Gels or Novex Tris-Glycine Plus Midi Gels. In addition to the Novex Tris-Glycine Mini Gels or Novex Tris-Glycine Plus Midi Gels and buffers, this convenient package even contains a Mini Gel Tank with or without Mini Blot modules, or SureLock Tandem Midi Gel Tank and our PageRuler Pre-Stained Protein Ladder for easy protein separation of broad molecular weights.

The Novex Tris-Glycine Welcome Packs contains:

  • Mini Gel Tank or SureLock Tandem Midi Gel Tank
  • Novex Tris-Glycine Mini Gels, WedgeWell format or Novex Tris-Glycine Plus Midi Gels (2 boxes, 20 gels)
  • Novex Tris-Glycine SDS Running Buffer (10X)
  • Novex Tris-Glycine SDS Sample Buffer (2X)
  • NuPAGE Sample Reducing Agent (10X)
  • PageRuler Plus Prestained Protein Ladder, 10 to 250 kDa
  • NEW Packs including Mini Blot Modules available

About Novex Tris-Glycine Gels:

The Tris-glycine gel chemistry is robust for a wide range of sample types. Based on the traditional Laemmli system, Novex Tris-Glycine gels provide high-quality performance and separation of a wide range of proteins into well-resolved bands and are compatible with samples containing detergents and high salt concentrations. The Novex Tris-Glycine mini gels, WedgeWell format, feature easier-to-load, larger-capacity wells that let you load up to 60 μL of sample.

Novex Tris-Glycine mini gels are offered in nine polyacrylamide concentrations: 6, 8, 10, 12, 14, and 16 percent, and 4–12%, 4–20%, and 8–16% gradient and multiple well formats. Novex Tris-Glycine Plus midi gels feature a conventional sample well and are offered in five polyacrylamide concentrations: 10 and 12 percent, and 4–12%, 4–20%, and 8–16% gradient and multiple well formats.

Mini Gels

Midi Gels

NuPAGE Tris-Acetate Welcome Packs

The NuPAGE Tris-Acetate Welcome Packs contain all components required to perform protein gel electrophoresis using NuPAGE Tris-Acetate mini or midi gels.In addition to the NuPAGE Tris-Acetate mini or midi gels and buffers, this convenient package even contains a Mini Gel Tank with or without Mini Blot modules, or SureLock Tandem Midi Gel Tank and our HiMark Pre-Stained Protein Standard for easy high molecular weight protein separation.

The NuPAGE Tris-Acetate Welcome Packs contain:

  • Mini Gel Tank or SureLock Tandem Midi Gel Tank
  • NuPAGE Tris-Acetate mini or midi gels (2 boxes, 20 gels)
  • NuPAGE Tris-Acetate SDS Running Buffer (20X)
  • NuPAGE LDS Sample Buffer (4X)
  • NuPAGE Sample Reducing Agent (10X)
  • HiMark Pre-stained Protein Standard
  • NEW Packs including Mini Blot Modules available

About NuPAGE Tris-Acetate Gels:

The Tris-Acetate gel chemistry enables optimal separation of high molecular weight proteins when used with an SDS running buffer. NuPAGE Tris-Acetate gels offer an environment of pH 8.1 that minimizes protein modifications and results in sharper bands. NuPAGE Tris-Acetate gels can also be run with Novex Tris-Glycine Native Running Buffer to resolve native proteins more effectively than a Tris-glycine gel system.

The NuPAGE Tris-Acetate gels are available in two polyacrylamide concentrations: 7 and 3–8% gradient and multiple well formats.

Mini Gels

Midi Gels

Novex Tricine Welcome Pack

The Novex Tricine Welcome Pack contains all components required to perform protein gel electrophoresis using Novex Tricine gels. Besides the Novex Tricine gels and buffers, this convenient package even contains the Mini Gel Tank with or without Mini Blot modules, and our Spectra Multicolor Low Range Protein Ladder for easy low molecular weight protein separation.

The Novex Tricine Welcome Pack contains:

  • Mini Gel Tank
  • Novex Tricine Mini Gels (2 boxes, 20 gels)
  • Novex Tricine SDS Running Buffer (10X)
  • Novex Tricine SDS Sample Buffer (2X)
  • NuPAGE Sample Reducing Agent (10X)
  • Spectra Multicolor Low Range Protein Ladder
  • NEW Packs including Mini Blot Modules available

About Novex Tricine gels:

Tricine gel chemistry enables the optimum separation of low molecular weight proteins and peptides. Novex Tricine gels are high-resolution gels for peptide and low molecular weight protein analyses. The Novex Tricine gel system is a modification of the Tris-glycine system in which tricine replaces glycine in the running buffer. This system uses a discontinuous buffer system specifically designed for the resolution of low molecular weight proteins.

The Novex Tricine gels are offered in three polyacrylamide concentrations: 10, 16 and 10–20% gradient and multiple well formats.

Welcome Packs for Protein Expression

Protein gels welcome packs for protein expression are available in mini gel and midi gel formats designed for use in protein expression experiments and subsequent purification steps. In addition to the components included with the standard protein gels welcome packs, welcome packs for protein expression include SimplyBlue SafeStain to enable fast separation and gel staining so that you can quickly assess your expression and purification results.

The Bolt Mini Bis-Tris and NuPAGE Midi Bis-Tris Welcome Packs are designed to be used for any protein expression application or expression system, such as our Expi Transient Protein Expression Systems.

The protein gels welcome packs for protein expression contain:

  • Mini Gel Tank or SureLock Tandem Midi Gel Tank
  • Invitrogen precast Bolt Bis-Tris Plus mini (12-well) or NuPAGE Bis-Tris midi (20-well) 4–12% gradient protein gels (2 boxes, 20 gels)
  • MES Running buffer (20X)
  • LDS sample buffer (4X)
  • Bolt or NuPAGE sample reducing agent (10X)
  • PageRuler Plus Prestained Protein Ladder, 10 to 250 kDa
  • SimplyBlue SafeStain, 1L

SimplyBlue SafeStain, included in the protein gels welcome packs for protein expression, is a ready-to-use, fast, sensitive, and safe Coomassie G-250 stain for visualizing protein bands on polyacrylamide gels. The SimplyBlue SafeStain protocol is easy to perform and can be completed in less than three hours. For added speed, a simple microwave procedure can be completed in 12 minutes. Destaining is not required but may be performed with deionized water to achieve maximum sensitivity. This stain is completely non-hazardous and does not require methanol or acetic acid fixatives or destains, creating a healthier lab environment.

XCell SureLock Welcome Packs

The XCell SureLock Mini-Cell Welcome Packs contain all components required to perform gel electrophoresis using the XCell SureLock Mini-Cell and Invitrogen pre-cast gels in four different gel chemistries. Each Welcome pack also include a compatible prestained protein ladder.

About the XCell SureLock Mini-Cell

The XCell SureLock Mini-Cell is a vertical mini-protein gel electrophoresis system compatible with all Invitrogen mini precast gels and Surecast handcast gels. The Mini-Cell is simple, sturdy, and easy to use. Each XCell SureLock Mini-Cell can accommodate up to two gels per run. Run times may vary depending on the gel chemistry and buffer conditions used.

For Research Use Only. Not for use in diagnostic procedures.