Search Thermo Fisher Scientific
- Order Status
- Quick Order
-
Don't have an account ? Create Account
Search Thermo Fisher Scientific
The Thermo Scientific Pierce Standards are designed for a variety of applications, including sensitivity assessment, determination of digestion efficiency, chromatography assessment and/or as controls for sample analysis. Standards range from single component formulations to complex human-based digests. Each standard is provided with a Certificate of Analysis.
![]() | ![]() | ![]() | ![]() | ![]() | |
Pierce BSA Digest Standard | Pierce 6-Protein Mixture Standard | Pierce Yeast Digest Standard | Pierce HeLa Protein Digest Standard | Pierce TMT11plex Yeast Digest Standard | |
---|---|---|---|---|---|
Components (abbreviated) | BSA tryptic peptides | Lysozyme, BSA, Cytochrome C, Alcohol dehydrogenase, B-galactosidase, Apotransferrin (multi-species) | Yeast lysate peptide digest | HeLa lysate peptides | Yeast lysate peptide digest |
Format | Lyophilized | Lyophilized | Lyophilized | Lyophilized | Lyophilized |
Primary application | Protein sample control | Chromatography assessment | Monitoring LC/MS system performance | Complex sample control | Complex sample for TMT-labeling |
Complexity of standard | ++ | +++ | +++ | ++++ | +++ |
Recommended storage | -20°C | -20°C | -20°C | -20°C | -20°C |
Order | Order | Order | Order | Order |
![]() | |
Pierce Reserpine Standard for LC-MS | |
---|---|
Components (abbreviated) | Reserpine molecule |
Format | Liquid |
Primary application | Sensitivity assessment |
Complexity of standard | + |
Recommended storage | 4°C |
Order |
![]() | ![]() | ![]() | |
Pierce Peptide Retention Time Calibration Mixture | Pierce LC-MS/MS System Suitability Standard (7 x 5 Mix) | Pierce HeLa Digest/PRTC Standard | |
---|---|---|---|
Components (abbreviated) | 15 heavy tryptic peptides (yeast) | 7 yeast tryptic peptides (5 variations of light or heavy amino acids) | Mixture of 10 µg of HeLa protein digest with 5 pmol PRTC peptides |
Format | Frozen liquid | Frozen liquid | Lyophilized |
Primary application | Chromatography assessment | Targeted MS Assay control | Monitoring LC/MS system performance |
Complexity of standard | ++ | ++ | ++++ |
Recommended storage | -80°C | -80°C | -20°C |
Order | Order | Order |
![]() | |
Pierce Intact Protein Standard Mix | |
---|---|
Components (abbreviated) | IGF-I LR3, Thioredoxin, Protein G, Carbonic Anhydrase II, Protein AG (chimeric), Exo Klenow |
Format | Lyophilized |
Primary application | Top down method development |
Complexity of standard | +++ |
Recommended storage | -20°C |
Order |
![]() | ![]() | ![]() | ![]() | ![]() | |
Pierce BSA Digest Standard | Pierce 6-Protein Mixture Standard | Pierce Yeast Digest Standard | Pierce HeLa Protein Digest Standard | Pierce TMT11plex Yeast Digest Standard | |
---|---|---|---|---|---|
Components (abbreviated) | BSA tryptic peptides | Lysozyme, BSA, Cytochrome C, Alcohol dehydrogenase, B-galactosidase, Apotransferrin (multi-species) | Yeast lysate peptide digest | HeLa lysate peptides | Yeast lysate peptide digest |
Format | Lyophilized | Lyophilized | Lyophilized | Lyophilized | Lyophilized |
Primary application | Protein sample control | Chromatography assessment | Monitoring LC/MS system performance | Complex sample control | Complex sample for TMT-labeling |
Complexity of standard | ++ | +++ | +++ | ++++ | +++ |
Recommended storage | -20°C | -20°C | -20°C | -20°C | -20°C |
Order | Order | Order | Order | Order |
![]() | |
Pierce Reserpine Standard for LC-MS | |
---|---|
Components (abbreviated) | Reserpine molecule |
Format | Liquid |
Primary application | Sensitivity assessment |
Complexity of standard | + |
Recommended storage | 4°C |
Order |
![]() | ![]() | ![]() | |
Pierce Peptide Retention Time Calibration Mixture | Pierce LC-MS/MS System Suitability Standard (7 x 5 Mix) | Pierce HeLa Digest/PRTC Standard | |
---|---|---|---|
Components (abbreviated) | 15 heavy tryptic peptides (yeast) | 7 yeast tryptic peptides (5 variations of light or heavy amino acids) | Mixture of 10 µg of HeLa protein digest with 5 pmol PRTC peptides |
Format | Frozen liquid | Frozen liquid | Lyophilized |
Primary application | Chromatography assessment | Targeted MS Assay control | Monitoring LC/MS system performance |
Complexity of standard | ++ | ++ | ++++ |
Recommended storage | -80°C | -80°C | -20°C |
Order | Order | Order |
![]() | |
Pierce Intact Protein Standard Mix | |
---|---|
Components (abbreviated) | IGF-I LR3, Thioredoxin, Protein G, Carbonic Anhydrase II, Protein AG (chimeric), Exo Klenow |
Format | Lyophilized |
Primary application | Top down method development |
Complexity of standard | +++ |
Recommended storage | -20°C |
Order |
Thermo Scientific Pierce Digestion Indicator is a single, non-mammalian recombinant protein (26kDa) with five signature peptides for use in determining the digestion efficiency and reproducibility across multiple samples. The protein sequence and recommended peptides to monitor across samples are supplied with the product instructions.
The TMT11plex Yeast Digest Standard can be used to assess instrument readiness and protein quantification accuracy. The TMT11plex Yeast Digest Standard was used to assess MS instrument readiness on the precision of quantification of a housekeeping protein, ENO2. Protein abundance was scaled to the parental lines in Proteome Discover 2.2 software, with expected ratios of 1:1. A total of 500 ng of the Pierce TMT11plex Yeast Digest Standard was measured using a 50 min gradient on an UltiMate 3000 RSLCnano system with a synchronous precursor selection (SPS)-MS3 (SPS-MS3) method of the Orbitrap Fusion Lumos Tribrid Mass Spectrometer.
The TMT11plex Yeast Digest Standard can be used to assess instrument readiness and protein quantification accuracy. The TMT11plex Yeast Digest Standard was used to assess MS instrument readiness on the precision of quantification of a housekeeping protein, ENO2. Protein abundance was scaled to the parental lines in Proteome Discover 2.2 software, with expected ratios of 1:1. A total of 500 ng of the Pierce TMT11plex Yeast Digest Standard was measured using a 50 min gradient on an UltiMate 3000 RSLCnano system with a synchronous precursor selection (SPS)-MS3 (SPS-MS3) method of the Orbitrap Fusion Lumos Tribrid Mass Spectrometer.
For Research Use Only. Not for use in diagnostic procedures.