Thermo Scientific Pierce Calibration Solutions for mass spectrometry are ready-to-use liquid formulations that can quickly calibrate Thermo Scientific LC-MS instrumentation. These mixtures are composed of highly purified, ionizable molecules or polymers specifically designed for positive or negative calibration of Thermo Scientific ion trap, orbitrap and triple quadrupole instruments. The calibration solutions are manufactured at an ISO 9001 facility and each lot is quality controlled with strict specifications. The stable solutions are provided in a leak-proof, high-purity PTFE bottle.

  • Strong peaks—mixture of instrument-optimized components in a mass spec compatible solvent  solution
  • Ready to use—load calibration solution into a syringe and inject into the instrument
  • High-purity—mass spectrometry-grade reagents in a non-leachable container
  • Stable—store at room temperature or refrigerator for more than one year
  • Validated—all calibration solutions have been fully tested using Thermo Scientific Mass Spectrometers

Choose the right calibration solution for your platform

 
 Pierce FlexMix Calibration SolutionPierce LTQ ESI Positive Ion Calibration SolutionPierce LTQ Velos ESI Positive Ion Calibration SolutionPierce ESI Negative Ion Calibration Solution
Recommended for Thermo Scientific mass spec instrument seriesAll Orbitrap Tribrid MS, All Orbitrap Exploris MS, Orbitrap Astral MS, Orbitrap IQ-X, Orbitrap EclipseLTQ, LTQ Orbitrap, LXQ, LCQ FLEET, ExactiveLTQ Velos/Velos Pro, LTQ Orbitrap Velos/Orbitrap Velos Pro, Orbitrap Elite,
Q Exactive, Orbitrap Fusion Tribrid
LTQ, LTQ Velos, LTQ Orbitrap, Exactive
Components16 components†Caffeine, MRFA, Ultramark 1621Caffeine, MRFA, Ultramark 1621, n-Butyl-amineSDS, sodium taurocholate,
Ultramark 1621
Mass range50-3000195-152274-1522265-1680
Calibration modePositive and negativePositivePositiveNegative
StorageRoom tempRoom tempRoom tempRoom temp
 Order nowOrder nowOrder nowOrder now

† See product page for details

 
 Pierce Triple Quadrupole Calibration SolutionPierce Triple Quadrupole Calibration Solution, Extended Mass Range
Recommended for Thermo Scientific mass spec instrument seriesTSQ Quantum, TSQ Discovery, TSQ Quantum Access,TSQ Vantage, TSQ Endura, TSQ QuantivaTSQ Quantum, TSQ Discovery, TSQ Quantum Access,
TSQ Vantage, TSQ Endura, TSQ Quantiva, TSQ Fortis, TSQ Quantis, TSQ Altis
ComponentsTyrosine1, Tyrosine3, Tyrosine617 components†
Mass range182-99769-2722 (Pos)
69-2934 (Neg)
Calibration modePositivePositive and Negative
Storage2° to 8°C2° to 8° C
 Order nowOrder now

† See product page for details

 
 Pierce FlexMix Calibration SolutionPierce LTQ ESI Positive Ion Calibration SolutionPierce LTQ Velos ESI Positive Ion Calibration SolutionPierce ESI Negative Ion Calibration Solution
Recommended for Thermo Scientific mass spec instrument seriesAll Orbitrap Tribrid MS, All Orbitrap Exploris MS, Orbitrap Astral MS, Orbitrap IQ-X, Orbitrap EclipseLTQ, LTQ Orbitrap, LXQ, LCQ FLEET, ExactiveLTQ Velos/Velos Pro, LTQ Orbitrap Velos/Orbitrap Velos Pro, Orbitrap Elite,
Q Exactive, Orbitrap Fusion Tribrid
LTQ, LTQ Velos, LTQ Orbitrap, Exactive
Components16 components†Caffeine, MRFA, Ultramark 1621Caffeine, MRFA, Ultramark 1621, n-Butyl-amineSDS, sodium taurocholate,
Ultramark 1621
Mass range50-3000195-152274-1522265-1680
Calibration modePositive and negativePositivePositiveNegative
StorageRoom tempRoom tempRoom tempRoom temp
 Order nowOrder nowOrder nowOrder now

† See product page for details

 
 Pierce Triple Quadrupole Calibration SolutionPierce Triple Quadrupole Calibration Solution, Extended Mass Range
Recommended for Thermo Scientific mass spec instrument seriesTSQ Quantum, TSQ Discovery, TSQ Quantum Access,TSQ Vantage, TSQ Endura, TSQ QuantivaTSQ Quantum, TSQ Discovery, TSQ Quantum Access,
TSQ Vantage, TSQ Endura, TSQ Quantiva, TSQ Fortis, TSQ Quantis, TSQ Altis
ComponentsTyrosine1, Tyrosine3, Tyrosine617 components†
Mass range182-99769-2722 (Pos)
69-2934 (Neg)
Calibration modePositivePositive and Negative
Storage2° to 8°C2° to 8° C
 Order nowOrder now

† See product page for details

Looking for a calibration solution to assess or calibrate column chromatography?

Thermo Scientific Pierce Peptide Retention Time Calibration Mixture contains a mixture of 14 heavy yeast peptides (hydrophobicity range 7.56-46.66) and is ideal for optimizing and assessing LC parameters,  identifying the total peptide elution window, and optimizing MS parameters.


Featured data

Thermo Scientific Pierce FlexMix Calibration Solution chromatograms

Thermo Scientific Pierce FlexMix Calibration Solution chromatograms. Sample chromatograms of in positive and negative modes.

Chromatographic analysis of the Thermo Scientific Pierce Peptide Retention Time Calibration Mixture.
Chromatographic analysis of the Thermo Scientific Pierce Peptide Retention Time Calibration Mixture. The Pierce Retention Time Calibration Mixture was also analyzed on a Thermo Scientific TSQ Vantage Mass Spectrometer using a Thermo Scientific Hypersil GOLD C18 column (1.0 x 150 mm) with a 1.0% per minute gradient at 120 μL per minute. 
Thermo Scientific Pierce FlexMix Calibration Solution chromatograms

Thermo Scientific Pierce FlexMix Calibration Solution chromatograms. Sample chromatograms of in positive and negative modes.

Chromatographic analysis of the Thermo Scientific Pierce Peptide Retention Time Calibration Mixture.
Chromatographic analysis of the Thermo Scientific Pierce Peptide Retention Time Calibration Mixture. The Pierce Retention Time Calibration Mixture was also analyzed on a Thermo Scientific TSQ Vantage Mass Spectrometer using a Thermo Scientific Hypersil GOLD C18 column (1.0 x 150 mm) with a 1.0% per minute gradient at 120 μL per minute. 

For Research Use Only. Not for use in diagnostic procedures.