Search Thermo Fisher Scientific
- Contáctenos
- Orden Rápida
-
¿No tiene una cuenta? Crear una cuenta
Search Thermo Fisher Scientific
Gain more confidence and invest in your lab’s future via Thermo Scientific single quadrupole mass spectrometry (MS). MS provides sensitivity and selectivity for your analyses, giving you more insight into your samples and ability to resolve difficult separations, including co-eluting peaks, using differing mass-to-charge (m/z) ratios. Our single quadrupole MS systems set new standards for robustness and ease-of-use. They are built for every day, reliable routine operation with seamless integration into your HPLC or UHPLC system.
A single quadrupole mass spectrometer contains one quadrupole mass analyzer. The quadrupole mass analyzer acts as a mass filter, allowing users to select either a specific m/z ratio (i.e. one analyte) they are interested in detecting (i.e., single ion monitoring), or a range of m/z ratios (i.e., various analytes) at the same time (i.e., full scan monitoring).
ISQ EM Flexible LC-MS analysis with an extended mass range (HESI and HESI/APCI) | ISQ EC Routine IC-MS and LC-MS analysis optimized for small molecules | ||
---|---|---|---|
Performance | Application | Liquid Chromatography | Ion Chromatography and Liquid Chromatography |
Mass Range | 10 – 2000 m/z | 10 – 1250 m/z | |
Supported Modes | Full scan / SIM | Full scan / SIM | |
Mass Resolution | Unit (≤ 1.0 Da) | Unit (≤ 1.0 Da) | |
Mass Accuracy | < ± 0.1 Da | < ± 0.1 Da | |
Scan Rate, max | Up to 20000 (Da/s) | Up to 20000 (Da/s) | |
Stability | < 0.1 Da over 48 h | < 0.1 Da over 48 h | |
Source Details | Type | HESI and HESI/APCI | HESI |
Max Flow Rate | 2mL/min | 2mL/min |
A single quadrupole mass spectrometer contains one quadrupole mass analyzer. The quadrupole mass analyzer acts as a mass filter, allowing users to select either a specific m/z ratio (i.e. one analyte) they are interested in detecting (i.e., single ion monitoring), or a range of m/z ratios (i.e., various analytes) at the same time (i.e., full scan monitoring).
ISQ EM Flexible LC-MS analysis with an extended mass range (HESI and HESI/APCI) | ISQ EC Routine IC-MS and LC-MS analysis optimized for small molecules | ||
---|---|---|---|
Performance | Application | Liquid Chromatography | Ion Chromatography and Liquid Chromatography |
Mass Range | 10 – 2000 m/z | 10 – 1250 m/z | |
Supported Modes | Full scan / SIM | Full scan / SIM | |
Mass Resolution | Unit (≤ 1.0 Da) | Unit (≤ 1.0 Da) | |
Mass Accuracy | < ± 0.1 Da | < ± 0.1 Da | |
Scan Rate, max | Up to 20000 (Da/s) | Up to 20000 (Da/s) | |
Stability | < 0.1 Da over 48 h | < 0.1 Da over 48 h | |
Source Details | Type | HESI and HESI/APCI | HESI |
Max Flow Rate | 2mL/min | 2mL/min |
The easy-to-use Thermo Scientific ISQ EM Single Quadrupole Mass Spectrometer allows for flexible LC-MS analysis, with an extended mass range to detect small and large molecules, and an optional HESI or dual HESI/APCI ionization probe to target polar and non-polar compounds.
The Thermo Scientific ISQ EC Single Quadrupole Mass Spectrometer enables novices and experts alike to run routine MS and improve analytical confidence by detecting small molecules with high sensitivity in both simple and complex matrices.
Our LC-MS on-demand webinar series expands your application knowledge for pharma, biopharma, environmental, omics, food, forensics and clinical research and more. Learn how the latest high-performance mass spectrometry solutions can enable your laboratory to solve your most pressing analytical challenges, regardless of sample type.