Semiconductor device packaging analysis

Performance, power efficiency, area, and cost are driving new integration approaches and innovations in advanced semiconductor device packaging. Integration schemes that extend into the Z-dimension provide greater performance and flexibility to meet the needs of application-specific use cases.

As advanced packaging techniques evolve, failure analysis challenges increase, requiring fast, precise, and accurate time-to-data.

Example of an advanced packaging semiconductor


 

Hydra FIB/SEM : Revolutionizing Semiconductor Failure Analysis

Engineering the next generation of advanced semiconductor packaging

Advanced packaging strives to improve performance, power efficiency and device reliability while continuing to reduce production costs and increase yield. 3D-IC, 2.5D, wafer level packaging,  and other advanced packaging schemes are becoming increasingly more complex and 3-dimensional. This can lead to a number of performance and reliability challenges, including:

  • Die level defects
  • Substrate imperfections
  • Through-silicon via (TSV) formation problems
  • Wafer thinning
  • Bonding and bump pitch issues
  • /ul>

    These require high-confidence fault isolation, nanoscale analysis, and repeatable workflows to accelerate process improvements and time-to-market.

     

    Advanced semiconductor packaging failure analysis

    Faults localization in advanced packaging devices is particularly challenging as many factors can result in device failures. These include chip integration, material mismatches, chip-package interactions, thermo-mechanical deformation, and bonding processes.

    This places a greater premium on precise fault localization and accurate root cause analysis solutions.

    Thermo Fisher Scientific offers a unique and comprehensive set of workflows to meet the failure analysis and defect characterization needs of advanced semiconductor packaging.

Example semiconductor packaging analysis workflows

1. Advanced packaging assembly failure isolation and analysis workflow:

2. In-die failure analysis workflow:

 

Style Sheet for Komodo Tabs

Techniques

Thermal Fault Isolation

Uneven distribution of local power dissipation can cause large, localized increases in temperature, leading to device failure. We offer unique solutions for thermal fault isolation with high-sensitivity lock-in infrared thermography (LIT).

Learn more ›

Sample Preparation of Semiconductor Devices

Thermo Scientific DualBeam systems provide accurate TEM sample preparation for atomic-scale analysis of semiconductor devices. Automation and advanced machine learning technologies produce high-quality samples, at the correct location, and a low cost per sample.

Learn more ›

Semiconductor Analysis and Imaging

Thermo Fisher Scientific offers scanning electron microscopes for every function of a semiconductor lab, from general imaging tasks to advanced failure analysis techniques requiring precise voltage-contrast measurements.

Learn more ›

Device Delayering

Shrinking feature size, along with advanced design and architecture, results in increasingly challenging failure analysis for semiconductors. Damage-free delayering of devices is a critical technique for the detection of buried electrical faults and failures.

Learn more ›

Nanoprobing

As device complexity increases, so does the number of places defects have to hide. Nanoprobing provides the precise localization of electrical faults, which is critical for an effective transmission electron microscopy failure analysis workflow.

Learn more ›

Thermal Fault Isolation

Uneven distribution of local power dissipation can cause large, localized increases in temperature, leading to device failure. We offer unique solutions for thermal fault isolation with high-sensitivity lock-in infrared thermography (LIT).

Learn more ›

Sample Preparation of Semiconductor Devices

Thermo Scientific DualBeam systems provide accurate TEM sample preparation for atomic-scale analysis of semiconductor devices. Automation and advanced machine learning technologies produce high-quality samples, at the correct location, and a low cost per sample.

Learn more ›

Semiconductor Analysis and Imaging

Thermo Fisher Scientific offers scanning electron microscopes for every function of a semiconductor lab, from general imaging tasks to advanced failure analysis techniques requiring precise voltage-contrast measurements.

Learn more ›

Device Delayering

Shrinking feature size, along with advanced design and architecture, results in increasingly challenging failure analysis for semiconductors. Damage-free delayering of devices is a critical technique for the detection of buried electrical faults and failures.

Learn more ›

Nanoprobing

As device complexity increases, so does the number of places defects have to hide. Nanoprobing provides the precise localization of electrical faults, which is critical for an effective transmission electron microscopy failure analysis workflow.

Learn more ›

Samples


Semiconductor Materials and Device Characterization

As semiconductor devices shrink and become more complex, new designs and structures are needed. High-productivity 3D analysis workflows can shorten device development time, maximize yield, and ensure that devices meet the future needs of the industry.

Learn more ›


Products

Style Sheet for Instrument Cards Original

Hyperion II System

  • Atomic Force Probing
  • Localize transistor faults
  • Integrated PicoCurrent (CAFM)

nProber IV

  • Localize transistor and BEOL faults
  • Thermal nanoprobing (-40°C to 150°C)
  • Semi-automated operation

Talos F200E TEM

  • High-quality (S)TEM imaging of semiconductor and microelectronic devices
  • Precise, high-speed chemical characterization with EDS
  • Dedicated semiconductor-related applications

Metrios AX TEM

  • Automation options to support quality, consistency, metrology, and reduced OPEX
  • Leverages machine learning for superior autofunctions and feature recognition
  • Workflows for both in-situ and ex-situ lamella preparation

ELITE System

  • Electrical defect localization
  • Thermal mapping
  • Advanced packaging analysis

Helios 5 PFIB DualBeam

  • Gallium-free STEM and TEM sample preparation
  • Multi-modal subsurface and 3D information
  • Next-generation 2.5 μA xenon plasma FIB column

Helios 5 EXL DualBeam

  • Low-voltage performance for high sample preparation quality
  • Ultra-high-resolution immersion-lens field-emission SEM column
  • Automated handling of 300 mm FOUP with EFEM (GEM300 compliant)

Helios 5 PXL PFIB Wafer DualBeam

  • PFIB beam current from 1pA–2.6µA
  • Faster yield learning and increased productivity
  • Automated handling of 300 mm FOUP with EFEM (GEM300 compliant
Style Sheet to change H2 style to p with em-h2-header class

Documents


Contact us

Style Sheet to change H2 style to p with em-h2-header class
Style Sheet for Support and Service footer
Style Sheet for Fonts
Style Sheet for Cards

Electron microscopy services for
semiconductors

To ensure optimal system performance, we provide you access to a world-class network of field service experts, technical support, and certified spare parts.

Learn more ›