Search Thermo Fisher Scientific
- Contact Us
- Quick Order
-
Don't have an account ? Create Account
Search Thermo Fisher Scientific
Assessing cell viability is a key step in daily cell manipulation and is required for accurate and efficient downstream processing. In bright-field microscopy, the most commonly used method is trypan blue staining; however, many fluorescent options also exist and are commonly used in microscopy and flow cytometry applications.
The three commonly used viability kits listed below are discussed within this application note, but with the flexibility offered by the Invitrogen™ Countess™ II FL Automated Cell Counter incorporating Invitrogen™ EVOS™ Light Cubes, you have the ability to analyze cell viability using a variety of proven reagents, including: propidium iodide, ethidium homodimer, Invitrogen SYTOX™ dyes, 7-AAD, Invitrogen ReadyProbes™ reagents, acridine orange, and kits such as the Invitrogen LIVE/DEAD™ Viability/Cytotoxicity Kit.
Ubiquitous intracellular esterase activity and an intact plasma membrane are distinguishing characteristics of live cells. The LIVE/DEAD Viability/Cytotoxicity Kit quickly discriminates live from dead cells by simultaneously staining with green-fluorescent calcein AM to indicate intracellular esterase activity and red-fluorescent ethidium homodimer-1 (EthD-1) to indicate loss of plasma membrane integrity (Figure 1). It is adaptable to most eukaryotic cells where cytotoxic conditions produce these cellular effects. This fluorescence-based method of assessing cell viability can be used in place of trypan blue exclusion, 51Cr release assay, and similar methods for determining cell viability and cytotoxicity.
Cell-permeant dye that is converted to fluorescent calcein by live-cell esterase activity to produce intense, uniform green fluorescence. Calcein AM is detected with standard FITC/GFP filter sets.
High-affinity stain that enters cells with damaged membranes and undergoes a 40-fold enhancement of fluorescence upon binding to nucleic acids, producing bright red fluorescence in dead cells. EthD-1 is excluded by the intact plasma membrane of live cells. EthD-1 can be detected with RFP and Invitrogen™ Texas Red™ dye filter sets. Background fluorescence levels are low with this assay because the dyes are virtually nonfluorescent before interacting with cells.
Figure 1. Viability assay via cell staining using the LIVE/DEAD Viability/Cytotoxicity Kit. Live and heat-killed U2OS cells were mixed in an approximate 1:1 ratio, and then stained with calcein AM and EthD-1 supplied with the kit. The resultant suspension was then evaluated using the GFP and Texas Red (TxRed) Light Cubes with the Countess II FL Automated Cell Counter.
The ReadyProbes Cell Viability Imaging Kit, Blue/Green, is a ready-to-use kit that can be used to quickly and easily determine cell viability. Just add 2 drops each of room temperature–stable Invitrogen™ NucBlue™ Live reagent and NucGreen™ Dead reagent to 1 mL of cell growth medium, and then determine viability by counting total vs. dead cells (Figure 2).
Stains the nuclei of all cells; detected with a standard DAPI filter.
Stains only the nuclei of dead cells with compromised plasma membranes; detected with standard FITC/GFP (green) filter sets.
Figure 2. Viability assay via cell staining using the ReadyProbes™ Cell Viability Imaging Kit, Blue/Green. Live and heat-killed U2OS cells were mixed in an approximate 1:1 ratio, and then stained with NucBlue™ Live reagent and NucGreen™ Dead reagent supplied with the kit. The resultant sample was then evaluated using the Countess™ II FL Automated Cell Counter with DAPI and GFP Light Cubes installed.
ReadyProbes Cell Viability Imaging Kit, Blue/Red, is a ready-to-use kit that can be used to quickly and easily determine cell viability. Just add 2 drops each of room temperature–stable NucBlue Live reagent and propidium iodide to 1 mL of cell growth medium, and then determine viability by counting total vs. dead cells (Figure 3).
Stains the nuclei of all cells; detected with a standard DAPI filter.
Stains only the nuclei of dead cells with compromised plasma membranes; detected with standard TRITC/RFP (orange) filter sets.
Figure 3. Viability assay via cell staining using the ReadyProbes™ Cell Viability Imaging Kit, Blue/Red. Live and heat-killed U2OS cells were mixed in an approximate 1:1 ratio, and then stained with NucBlue™ Live reagent and propidium iodide supplied with the kit. The resultant sample was then evaluated using the Countess™ II FL Automated Cell Counter with DAPI and RFP Light Cubes installed.
For Research Use Only. Not for use in diagnostic procedures.