Colorimetric ReadiLAMP™ kit, 100 reactions | Colorimetric ReadiLAMP™ kit, 1000 reactions | |
Reactions | 100 reactions and 1000 reactions | |
Test duration | ~30 mins – Direct LAMP assay ~1 hour – LAMP using purified RNA | |
Sample types | Saliva and Swabs | |
Detection | Colorimetric readout | |
Sensitivity | Direct: ≤250 copies/25 uL LAMP reaction Purified: ≤100 copies/25 uL LAMP reaction | |
Controls | Human Control Primer Mix and SARS-CoV-2 Control RNA | |
Test format | 1-96 samples at a time | |
Kit Contents | 100 Reactions | 1000 reactions |
Kit storage temperature | –20℃ | |
Instrument required | 65℃ heating block with heated lid | |
Regulatory classification | RUO | |
Catalogue Number | 100 reactions (Cat. No. A52539) or 1,000 reactions (Cat. No. A52544) |
Use this kit to either perform direct assay or purified assay. Either method yields quality results that are easy to interpret with blue being positive Sars-CoV-2 reactions and violet being negative results.
See the results of using our kit for various sample types and target infectious disease analytes. With color coded positive and negative results, interpreting the data is simple.
Figure 1. The Colorimetric ReadiLAMP Kit enables highly specific SARS-CoV-2 detection.
Samples from 12 unique nasopharyngeal donors (D1 – D12) were supplemented with γ-irradiated SARS-CoV-2 isolate USA-WA1/2020 (BEI Resources), Influenza A H1N1, or Influenza A H3N2 (ATCC) or 5.0 μL NATtrol™ Respiratory Pathogen Panel-1 or Panel-2 (RP1/RP2, Zeptometrix). RNA was purified using the MagMAX Viral/Pathogen II Nucleic Acid Isolation Kit and the Thermo Scientific KingFisher Flex Magnetic Particle Processor. The 25 μL Colorimetric ReadiLAMP reactions were incubated at 65 °C for 30 min. In all samples supplemented with SARS-CoV-2, a positive blue color change was observed, while all other virally supplemented samples and controls remained a negative purple color. [RP1 contains the following viral particles and bacteria: Influenza A H3N2 (Brisbane/10/07), Influenza A H1N1 (NY/02/2009), Rhinovirus (Type 1A), Adenovirus (Type 3), Parainfluenza (Type 1), Parainfluenza (Type 4), Metapneumovirus (Peru 6-2003), Chlamydia pneumoniae (CWL-029), Mycoplasma pneumoniae (M129), and Coxsackievirus (Type A1). Whereas RP2 contains the following viral particles and bacteria: from Influenza A H1 (New Caledonia/20/99), Influenza B (Florida/02/06), RSV (Type A), Parainfluenza (Type 2), Parainfluenza (Type 3), Coronavirus (HKU-1 recombinant), Coronavirus (OC43), Coronavirus (NL63), Coronavirus (229E), Bordetella pertussis (A639).]
Figure 2. The Colorimetric ReadiLAMP Kit efficiently detects multiple SARS-CoV-2 strains.
Fifteen strains of SARS-CoV-2 RNA were obtained and evaluated in the Colorimetric ReadiLAMP assay. Each 25 μL reaction included 2.5 x 101 – 1.0 x 104 copies of SAR-CoV-2 in a background of 50 ng human genomic DNA. After 65 °C incubation for 30 min, 80% of strains were detected at a sensitivity of 25 copies/ reaction with all strains being detected at 50 copies/ reaction. These detectable strains, obtained from ATCC, were Hong Kong (NR-52388), Italy (NR-52498), England (NR-52499), Singapore (NR-52501), Germany (NR-52502), USA-IL (NR-52503), USA-CA1 (NR-52504), USA-AZ (NR-52505), USA-WI (NR-52506), USA-CA3 (NR-52507), USA-CA4 (NR-52508), USA-CA2 (NR-52509), Chile-Santiago (NR-52510), USA-New York (NR-53518), and USA-WA (NR-52285).
Figure 3. Using saliva-derived samples, the Colorimetric ReadiLAMP kit detections as few as 20 copies SARS-CoV-2 per reaction.
Samples from 12 unique saliva donors (D1 - D12) were supplemented with γ-irradiated SARS-CoV-2 isolate USA-WA1/2020 (BEI Resources). RNA was purified using the MagMAX Viral/Pathogen II Nucleic Acid Isolation Kit and the Thermo Scientific KingFisher Flex Magnetic Particle Processor. The 25 μL Colorimetric ReadiLAMP reactions were assembled using 1.0 – 12.5 μL input sample containing 0 – 250 copies of SARS-CoV-2 per reaction. After a 65 °C incubation for 30 min, all samples containing SARS-CoV-2 RNA transitioned to blue, positive reactions, while non-templated reactions remained purple. To increase sensitivity, sample input volume may be increased to 50 % of the total reaction volume (12.5/ 25 μL) with the caveat that individual reaction sensitivity is dependent on sample type, donor, and RNA purity. For saliva, the minimum range that can be robustly detected varies from 20 – 100 copies/ reaction for uncomplicated to challenging samples, respectively.
Colorimetric ReadiLAMP™ kit, 100 reactions | Colorimetric ReadiLAMP™ kit, 1000 reactions | |
Reactions | 100 reactions and 1000 reactions | |
Test duration | ~30 mins – Direct LAMP assay ~1 hour – LAMP using purified RNA | |
Sample types | Saliva and Swabs | |
Detection | Colorimetric readout | |
Sensitivity | Direct: ≤250 copies/25 uL LAMP reaction Purified: ≤100 copies/25 uL LAMP reaction | |
Controls | Human Control Primer Mix and SARS-CoV-2 Control RNA | |
Test format | 1-96 samples at a time | |
Kit Contents | 100 Reactions | 1000 reactions |
Kit storage temperature | –20℃ | |
Instrument required | 65℃ heating block with heated lid | |
Regulatory classification | RUO | |
Catalogue Number | 100 reactions (Cat. No. A52539) or 1,000 reactions (Cat. No. A52544) |
Use this kit to either perform direct assay or purified assay. Either method yields quality results that are easy to interpret with blue being positive Sars-CoV-2 reactions and violet being negative results.
See the results of using our kit for various sample types and target infectious disease analytes. With color coded positive and negative results, interpreting the data is simple.
Figure 1. The Colorimetric ReadiLAMP Kit enables highly specific SARS-CoV-2 detection.
Samples from 12 unique nasopharyngeal donors (D1 – D12) were supplemented with γ-irradiated SARS-CoV-2 isolate USA-WA1/2020 (BEI Resources), Influenza A H1N1, or Influenza A H3N2 (ATCC) or 5.0 μL NATtrol™ Respiratory Pathogen Panel-1 or Panel-2 (RP1/RP2, Zeptometrix). RNA was purified using the MagMAX Viral/Pathogen II Nucleic Acid Isolation Kit and the Thermo Scientific KingFisher Flex Magnetic Particle Processor. The 25 μL Colorimetric ReadiLAMP reactions were incubated at 65 °C for 30 min. In all samples supplemented with SARS-CoV-2, a positive blue color change was observed, while all other virally supplemented samples and controls remained a negative purple color. [RP1 contains the following viral particles and bacteria: Influenza A H3N2 (Brisbane/10/07), Influenza A H1N1 (NY/02/2009), Rhinovirus (Type 1A), Adenovirus (Type 3), Parainfluenza (Type 1), Parainfluenza (Type 4), Metapneumovirus (Peru 6-2003), Chlamydia pneumoniae (CWL-029), Mycoplasma pneumoniae (M129), and Coxsackievirus (Type A1). Whereas RP2 contains the following viral particles and bacteria: from Influenza A H1 (New Caledonia/20/99), Influenza B (Florida/02/06), RSV (Type A), Parainfluenza (Type 2), Parainfluenza (Type 3), Coronavirus (HKU-1 recombinant), Coronavirus (OC43), Coronavirus (NL63), Coronavirus (229E), Bordetella pertussis (A639).]
Figure 2. The Colorimetric ReadiLAMP Kit efficiently detects multiple SARS-CoV-2 strains.
Fifteen strains of SARS-CoV-2 RNA were obtained and evaluated in the Colorimetric ReadiLAMP assay. Each 25 μL reaction included 2.5 x 101 – 1.0 x 104 copies of SAR-CoV-2 in a background of 50 ng human genomic DNA. After 65 °C incubation for 30 min, 80% of strains were detected at a sensitivity of 25 copies/ reaction with all strains being detected at 50 copies/ reaction. These detectable strains, obtained from ATCC, were Hong Kong (NR-52388), Italy (NR-52498), England (NR-52499), Singapore (NR-52501), Germany (NR-52502), USA-IL (NR-52503), USA-CA1 (NR-52504), USA-AZ (NR-52505), USA-WI (NR-52506), USA-CA3 (NR-52507), USA-CA4 (NR-52508), USA-CA2 (NR-52509), Chile-Santiago (NR-52510), USA-New York (NR-53518), and USA-WA (NR-52285).
Figure 3. Using saliva-derived samples, the Colorimetric ReadiLAMP kit detections as few as 20 copies SARS-CoV-2 per reaction.
Samples from 12 unique saliva donors (D1 - D12) were supplemented with γ-irradiated SARS-CoV-2 isolate USA-WA1/2020 (BEI Resources). RNA was purified using the MagMAX Viral/Pathogen II Nucleic Acid Isolation Kit and the Thermo Scientific KingFisher Flex Magnetic Particle Processor. The 25 μL Colorimetric ReadiLAMP reactions were assembled using 1.0 – 12.5 μL input sample containing 0 – 250 copies of SARS-CoV-2 per reaction. After a 65 °C incubation for 30 min, all samples containing SARS-CoV-2 RNA transitioned to blue, positive reactions, while non-templated reactions remained purple. To increase sensitivity, sample input volume may be increased to 50 % of the total reaction volume (12.5/ 25 μL) with the caveat that individual reaction sensitivity is dependent on sample type, donor, and RNA purity. For saliva, the minimum range that can be robustly detected varies from 20 – 100 copies/ reaction for uncomplicated to challenging samples, respectively.
For Research Use Only. Not for use in diagnostic procedures.