Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Applied Biosystems PowerUp SYBR Green Master Mix is a preformulated, optimized, and universal 2X master mix for real-time PCR (qPCR). This master mix is designed for exceptional performance to address even the most challenging qPCR applications. With features including a dual hot-start mechanism, contamination control, 72-hour benchtop stability, and broad instrument compatibility, PowerUp SYBR Green Master Mix is designed to deliver reliable results for all your gene expression analysis, NGS library quantification, and other quantitative analysis applications.
Key features of the PowerUp SYBR Green Master Mix include:
Provides exceptional specificity and helps prevent undesirable early activity of the polymerase at low temperatures, which can lead to non-specific amplification.
Room-temperature stability for up to 72 hours after plates are prepared for qPCR.
Allows for greater statistical significance when analyzing low-abundance transcripts and smaller relative differences in expression.
Compatible with standard or fast cycling.
Get results in less than 60 minutes with standard cycling or less than 30 minutes with fast cycling.
Inclusion of UNG and dUTP degrades any previously amplified PCR products and helps prevent contamination of subsequent qPCR reactions.
PowerUp SYBR Green Master Mix contains proprietary Dual-Lock Taq DNA Polymerase enzyme, which uses a combination of two hot-start mechanisms to control its activity. Providing tight control over Taq activation, this dual hot-start approach helps prevent undesirable early activity of the polymerase at low temperatures that can lead to non-specific amplification. Formulation of the Dual-Lock Taq into a convenient 2X pre-mix containing an optimized buffer system, proprietary additives, and detergents further improves the specificity of PowerUp SYBR Green Master Mix.
In an evaluation of 24 different primer sets with PowerUp SYBR Green Master Mix, a single melt curve was obtained in 100% of reactions without the need for primer optimization or redesign. The high specificity of the PowerUp SYBR Green Master Mix allows you to spend less time and money optimizing and redesigning primers to get high-quality data.
PowerUp SYBR Green Master Mix, with its Dual-Lock Taq DNA Polymerase, has been shown to generate consistent performance in preassembled reactions for up to 72 hours. The stability of this mix provides users the flexibility of setting up plates prior to cycling without impacting results.
Target |
T-0 hr |
T-72 hr |
∆Ct |
---|---|---|---|
ADAM10 |
25.2 |
25.6 |
0.4 |
APOA1 |
24.9 |
24.9 |
0.0 |
CCNB1 |
26.0 |
26.1 |
0.1 |
COL1A1 |
23.9 |
23.9 |
0.1 |
CTGF |
24.3 |
24.7 |
0.3 |
METTL3 |
26.3 |
26.7 |
0.3 |
Pre-PCR stability. Several targets were amplified using PowerUp SYBR Green Master Mix from 1 ng human cDNA on an Applied Biosystems StepOnePlus Real-Time PCR System immediately following reaction setup and after 72 hours incubation at room temperature in the dark. Single melt curves were confirmed for these assays at both the 0 hr and 72 hr time points.
Tight reproducibility allows for greater significance in analyzing low-abundant transcripts and smaller fold changes. PowerUp SYBR Green Master Mix, with its dual hot-start Taq DNA polymerase, demonstrates excellent reproducibility over a wide dynamic range for a variety of targets tested.
Generating consistent amplification across a wide dynamic range is fundamental to qPCR methodology and use of the ΔΔCt method for gene expression analysis. Unlike competitor mixes that can exhibit inhibition at high cDNA inputs and low correlation coefficients over a dynamic range experiment, PowerUp SYBR Green Master Mix efficiency is maintained over six logs of input to deliver maximum confidence in data quality.
Complete your qPCR workflow by pairing PowerUp SYBR Green Master Mix with sequence detection primers: high-quality, unlabeled oligos for use with SYBR dye in all your real-time PCR research applications. Sequence detection primers are synthesized using the same raw materials and carefully controlled processes as our TaqMan probes, ensuring consistency and quality in every batch.
For Research Use Only. Not for use in diagnostic procedures.