Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
The Thermo Scientific Orion3 Electrostatic Discharge Tester is designed to test for potentially destructive effects of ESD, enabling the identification and hardening of protection structures prior to full-scale production. Given the extremely high cost of integrated circuit production, as well as customer demands for precisely timed component delivery schedules, the Orion3 can save substantial costs in terms of time, material and lost opportunity (time-to-market). The high-resolution dual cameras permit easy and rapid discharge pin alignment during the test setup routine. Both the x- and y-axis are displayed simultaneously. The cameras may be left on during the test to monitor the pin alignment. Vacuum hold-down enables device testing regardless of device types and sizes.
The Orion3 is capable of performing FICDM (field induced or air discharge) testing to all popular industry standards. An event detector ensures each discharge occurs as expected, ensuring proper alignment and contact between the device and the system discharge pin. Events are logged and reported upon test completion, providing confirmation of pin discharge, and the indication of non-stressed pins that require retest. Testing can also be performed, using our LI-CCDM contact test method, which both charges and discharges the device through a controlled impedance environment, eliminating testing issues that can be seen when using air discharge methods.
JS-002, JEDEC, ESDA, AEC and LI-CCDM methods.
Bench height test area allows for an ergonomic work process.
High resolution dual cameras permit easy discharge pin alignment during test plan set-up.
Environmental monitor within the test area allows control of humidity levels during testing by flooding the area with user supplied dry air or nitrogen.
Event detector confirms ESD discharge and reports when a pin is not stressed.
Automatic waveform capture for calibration or device testing. Stores Ipeak and min/max values for each captured waveform.
Device under test (DUT) held in place by an internal vacuum pump; alignment assured via adjustable fixture.
Intuitive test set-up and test execution using the Thermo Scientific Scimitar software platform.
Integrated package outline editor allows creation of any device, including off grid.
Device definitions can be imported from legacy applications, other Scimitar applications, and in text based (x, y) formats.
Electrical Requirements |
| |
Test Voltage Range |
| |
Voltage |
| |
Description |
| |
Humidity Range |
| |
Item Description |
| |
Motion System |
| |
Specifications |
| |
Details |
| |
Temperature Range |
| |
Hertz |
| |
Unit Size |
| |
English | Metric | |
Test Area |
|
|
Size |
|
|
Depth |
|
|
Height |
|
|
Width |
|
|
Weight |
|
|
静電放電(ESD)管理計画においては、ESD感度の高い機器を特定することが必要です。当社は、使用機器の適格要件適合を補助するための完全な検査システムセットを提供しています。
ESDコンプライアンス検査
静電気放電(ESD)により、半導体や集積回路の機能および構造が損傷される可能性があります。私たちは、お客様のデバイスがESDコンプライアンス基準を満たしているか検証するための、包括的な検査装置を提供しています。
ESDコンプライアンス検査